N'Zanon Aly KONE

N'Zanon Aly KONE

Université de Man, Man, Montagnes, Côte d'Ivoire
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2023 in Catalysts
Verified
Journal Article
Open access
PDF file
N'Zanon Aly KONEN'Zanon Aly KONE
N'Zanon Aly KONE
NBNacer BELKESSA
Nacer BELKESSA
YSYoucef Serhane
Youcef Serhane
CLCoulibaly Sandotin Lassina
Coulibaly Sandotin Lassina
MKMahamadou Kamagate
Mahamadou Kamagate
Aymen Amin ASSADIAymen Amin ASSADI
Aymen Amin ASSADI
Mineralization of gaseous chlorobenzene (major VOC from cement plants) was studied in a continuous reactor using three advanced oxidation processes: (i) photocatalysis, (ii) Dielectric Barrier Discharge (DBD) plasma and (iii) DBD/TiO2-UV coupling. The work showed an overproduction of OH * and O * radicals in the reaction medium due to the interaction of Cl * and O3. A parametric study was carried out in order to determine the evolution of the removal efficiency as a function of the concentration, the flow rate and the applied voltage. Indeed, a variation of the flow rate from 0.25 to 1 m3/h resulted in a decrease in the degradation rate from 18 to 9%. Similarly, an increase in concentration from 13 to 100 mg/m3 resulted in a change in degradation rate from 18 to 4%. When the voltage was doubled from 6 to 12 kV, the degradation rate varied from 22 to 29 % (plasma) and from 53 to 75% (coupling) at 13 mg/m3. The evolution of COX and O3 was monitored during the experiments. When the voltage was doubled, the selectivity increased from 28 to 37% in the plasma alone and from 48 to 62 % in the coupled process. In addition, at this same voltage range, the amount of ozone formed varied from 10 to 66 ppm in plasma and 3 to 29 ppm in coupling. This degradation performance can be linked to a synergistic effect, which resulted in an increase in the intensity of the electric field of plasma by the TiO2 and the improvement in the performance of the catalyst following the bombardment of various high-energy particles of the plasma.

13 February 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
N'Zanon Aly KONEN'Zanon Aly KONE
N'Zanon Aly KONE
Aymen Amin ASSADIAymen Amin ASSADI
Aymen Amin ASSADI
NBNacer BELKESSA
Nacer BELKESSA
LKLotfi Khezami
Lotfi Khezami
SCSandotin Lassina Coulibaly
Sandotin Lassina Coulibaly
Abdeltif AmraneAbdeltif Amrane
Abdeltif Amrane
Chlorobenzene (CB) and Chloronaphthalene (CN) emissions from cement plant operations pose significant environmental risks. This study investigates the mass transfer effects of chlorinated aromatic Volatile Organic Compounds (VOCs), specifically CB and CN, in the gas phase of a continuous-tangential-flow annular photocatalytic reactor. The experiments involved introducing CB and CN into the reactor, and the degradation kinetics were analyzed using the Langmuir–Hinshelwood (L-H) model. The L-H model was applied to assess the impact of the flow rate, concentration, and relative humidity (% RH) on the degradation rate (DR). The results indicate that both the experimental and simulated degradation rates improved with increased flow rates (1 to 9 m3·h−1) and inlet concentrations (30 to 216 mg·m−3). This enhancement of the DR correlates with the availability of active OH* species on the TiO2 surface. The L-H model emphasizes the role of H2O molecules in VOC removal kinetics. The degradation rates increased with a rising water content (5 to 55%), but adverse effects on VOC conversion were observed beyond a 55% RH. This study reveals a mass transfer effect, with internal diffusional limitations in the TiO2 pores under operational conditions. The kinetics were predominantly controlled by chemical kinetics and catalyst pore availability. Furthermore, this study demonstrates a higher CB degradation than CN in the reactor and experimental conditions. For a concentration of 1.328 mM·m−3, the CB DR ranged from 0.70 to 2.84 µM·m2·s−1, as the flow rate varied from 1 to 9 m3·h−1. The CN DR varied from 0.60 to 2.20 µM·m2·s−1 within the same flow rate range.