Mineralization of gaseous chlorobenzene (major VOC from cement plants) was studied in a continuous reactor using three advanced oxidation processes: (i) photocatalysis, (ii) Dielectric Barrier Discharge (DBD) plasma and (iii) DBD/TiO2-UV coupling. The work showed an overproduction of OH * and O * radicals in the reaction medium due to the interaction of Cl * and O3. A parametric study was carried out in order to determine the evolution of the removal efficiency as a function of the concentration, the flow rate and the applied voltage. Indeed, a variation of the flow rate from 0.25 to 1 m3/h resulted in a decrease in the degradation rate from 18 to 9%. Similarly, an increase in concentration from 13 to 100 mg/m3 resulted in a change in degradation rate from 18 to 4%. When the voltage was doubled from 6 to 12 kV, the degradation rate varied from 22 to 29 % (plasma) and from 53 to 75% (coupling) at 13 mg/m3. The evolution of COX and O3 was monitored during the experiments. When the voltage was doubled, the selectivity increased from 28 to 37% in the plasma alone and from 48 to 62 % in the coupled process. In addition, at this same voltage range, the amount of ozone formed varied from 10 to 66 ppm in plasma and 3 to 29 ppm in coupling. This degradation performance can be linked to a synergistic effect, which resulted in an increase in the intensity of the electric field of plasma by the TiO2 and the improvement in the performance of the catalyst following the bombardment of various high-energy particles of the plasma.
Chlorobenzene (CB) and Chloronaphthalene (CN) emissions from cement plant operations pose significant environmental risks. This study investigates the mass transfer effects of chlorinated aromatic Volatile Organic Compounds (VOCs), specifically CB and CN, in the gas phase of a continuous-tangential-flow annular photocatalytic reactor. The experiments involved introducing CB and CN into the reactor, and the degradation kinetics were analyzed using the Langmuir–Hinshelwood (L-H) model. The L-H model was applied to assess the impact of the flow rate, concentration, and relative humidity (% RH) on the degradation rate (DR). The results indicate that both the experimental and simulated degradation rates improved with increased flow rates (1 to 9 m3·h−1) and inlet concentrations (30 to 216 mg·m−3). This enhancement of the DR correlates with the availability of active OH* species on the TiO2 surface. The L-H model emphasizes the role of H2O molecules in VOC removal kinetics. The degradation rates increased with a rising water content (5 to 55%), but adverse effects on VOC conversion were observed beyond a 55% RH. This study reveals a mass transfer effect, with internal diffusional limitations in the TiO2 pores under operational conditions. The kinetics were predominantly controlled by chemical kinetics and catalyst pore availability. Furthermore, this study demonstrates a higher CB degradation than CN in the reactor and experimental conditions. For a concentration of 1.328 mM·m−3, the CB DR ranged from 0.70 to 2.84 µM·m2·s−1, as the flow rate varied from 1 to 9 m3·h−1. The CN DR varied from 0.60 to 2.20 µM·m2·s−1 within the same flow rate range.
This study investigated the remediation of organic acid pollutants, specifically butyric acid (C4H8O) and valeric acid (C5H10O2), as well as their binary mixtures in the vapor phase at various ratios. The remediation process involved the use of a continuous pilot-scale reactor. A TiO2 catalyst was deposited on glass fiber tissue (GFT) and ultraviolet (UV) irradiation with an intensity of 20 W/m2. The main objective of this study was to assess the effectiveness of the photocatalytic process by oxidizing and mineralizing a mixture of carboxylic acids in a rectangular reactor at pilot scale. This was achieved by calculating the removal efficiency and the selectivity of CO2 (SCO2). Each individual compound was treated separately, followed by the treatment of binary mixtures with molar fractions of 0.25, 0.5, and 0.75. The concentration of pollutants at the inlet varied between 50, 100, 150, and 200 mg/m3, while the flowrate ranged from 2 to 6 m3/h. The obtained results for the removal efficiency of butyric acid, the binary acid mixture (25% butyric acid + 75% valeric acid), and valeric acid were satisfactory, with percentages of 58%, 32%, and 41%, respectively. It is evident that the selectivity toward CO2 is better for butyric acid compared to valeric acid and the binary carboxylic acid mixture, with values of 43.70%, 33.49%, and 21.96%, respectively, across all concentrations. A simulation model based on mass transfer and catalytic oxidation mechanisms was developed and successfully validated against the experimental data for each pollutant. Reusability tests conducted on the TiO2 on GFT, both in its initial (clean) state and after 50 h of the photocatalytic treatment of butyric acid, showed a 15% decrease in photocatalytic efficiency.
In this study, the degradation of naphthalene in water was performed via photocatalysis with two different configurations: UV-irradiated TiO2 deposited on cellulosic tissue and photocatalytic luminous textiles. The photocatalytic performance of these configurations was evaluated in terms of pollutant removal and mineralization yield. Moreover, the influence of key operating parameters, such as the initial pollutant concentration, solution turbidity, the number of tissues, and the type of irradiation, was investigated. The results showed a complete removal of 8 mg/L of naphthalene with photocatalytic luminous textiles after 4 h of UV irradiation, with a mineralization yield of 80%. The impact of the turbidity shows that at 90 NTU, reductions in photocatalytic activity of 30% and 10% were recorded for the UV-irradiated TiO2 deposed on cellulosic tissue and photocatalytic luminous textiles, respectively. The reactive oxygen species (ROS) concentrations were monitored during photocatalysis to better understand the contribution of each active species in the mechanism reaction of naphthalene oxidation. The results show that the hydroxyl radical (•OH) is responsible for 70% of pollutant oxidation. A scaling up of the water treatment with photocatalytic luminous textiles was performed. The extrapolation confirmed the same trends observed at the laboratory scale in terms of degradation and mineralization.