Abdeltif Amrane

Prof. Abdeltif Amrane

ISCR, University of Rennes, Rennes, Bretagne, France
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2024 in Water
Verified
Journal Article
Open access
PDF file
HTHICHEM Tahraoui
HICHEM Tahraoui
STselma toumi
selma toumi
MBMeriem Boudoukhani
Meriem Boudoukhani
NTNabil Touzout
Nabil Touzout
ASAsma Nour El Houda SID
Asma Nour El Houda SID
Jie ZhangJie Zhang
Jie Zhang
Safeguarding drinking water is a major public health and environmental concern because it is essential to human life but may contain pollutants that can cause illness or harm the environment. Therefore, continuous research is necessary to improve water treatment methods and guarantee its quality. As part of this study, the effectiveness of coagulation–flocculation treatment using aluminum sulfate (Al2(SO4)3) was evaluated on a very polluted site. Samplings were taken almost every day for a month from the polluted site, and the samples were characterized by several physicochemical properties, such as hydrogen potential (pH), electrical conductivity, turbidity, organic matter, ammonium (NH+4), phosphate (PO43−), nitrate (NO3−), nitrite (NO2−), calcium (Ca2+), magnesium (Mg2+), total hardness (TH), chloride (Cl−), bicarbonate (HCO3−), sulfate (SO42−), iron (Fe3+), manganese (Mn2+), aluminum (Al3+), potassium (K+), sodium (Na+), complete alkalimetric titration (TAC), and dry residue (DR). Then, these samples were treated with Al2(SO4)3 using the jar test method, which is a common method to determine the optimal amount of coagulant to add to the water based on its physicochemical characteristics. A mathematical model had been previously created using the support vector machine method to predict the dose of coagulant according to the parameters of temperature, pH, TAC, conductivity, and turbidity. This Al2(SO4)3 treatment step was repeated at the end of each month for a year, and a second characterization of the physicochemical parameters was carried out in order to compare them with those of the raw water. The results showed a very effective elimination of the various pollutions, with a very high rate, thus demonstrating the effectiveness of the Al2(SO4)3. The physicochemical parameters measured after the treatment showed a significant reduction in the majority of the physicochemical parameters. These results demonstrated that the coagulation–flocculation treatment with Al2(SO4)3 was very effective in eliminating the various pollutions present in the raw water. They also stress the importance of continued research in the field of water treatment to improve the quality of drinking water and protect public health and the environment.

13 December 2022 in Process Safety and Environmental Protection
Verified
Journal Article
Closed access
NBNasma Bouchelkia
Nasma Bouchelkia
HTHichem Tahraoui
Hichem Tahraoui
Abdeltif AmraneAbdeltif Amrane
Abdeltif Amrane
HBHayet Belkacemi
Hayet Belkacemi
JBJean-Claude Bollinger
Jean-Claude Bollinger
LMLotfi Mouni
Lotfi Mouni

15 January 2023 in Separations
Verified
Journal Article
Open access
PDF file
IAImessaoudene Ali
Imessaoudene Ali
SCSabrina CHEIKH
Sabrina CHEIKH
AHAmina Hadadi
Amina Hadadi
NHNadia Hamri
Nadia Hamri
JBJean-Claude BOLLINGER
Jean-Claude BOLLINGER
LMLotfi Mouni
Lotfi Mouni
In the present research, zeolite is used for the removal of toxic Congo red dye from water solution. The effects of different operating conditions such as hydrogen potential (pH), contact time (time), zeolite dose (D), initial dye concentration (C0), and ionic strength (I) are investigated for Congo red adsorption under batch mode. It was found that the adsorption process was greatly affected by the initial pH of the dye solution. The removal efficiency decreased from 97.68 to 5.22% when the pH varied from 3 to 5; thus, acidic conditions clearly improve Congo red adsorption on zeolite. At pH 3, an increase in C0 and I and decrease in D resulted in an increase in the adsorption capacity qe. The effects of these three parameters and their interactions were also investigated using the 23 full factorial design experiments approach where qe was chosen as the response. The results obtained from this method followed by the analysis of variance and the Student’s t-test show that, the influence of these parameters on dye adsorption process are in the order I < C0 < D. The kinetic studies revealed that adsorption follows a pseudo-second-order kinetic model. The adsorption isotherms experimental data were analyzed using the Langmuir, Freundlich, and Temkin isotherms models. The Freundlich isotherm was the best-fit model to the experimental data. The fitting of kinetics and isotherm models was evaluated by using non-linear modeling, R2, MSE, and RMSE.

1 March 2014 in Journal of Environmental Chemical Engineering
Verified
Journal Article
Closed access
YOYasmine Ait Ouaissa
Yasmine Ait Ouaissa
MCMalika Chabani
Malika Chabani
Abdeltif AmraneAbdeltif Amrane
Abdeltif Amrane
ABAicha Bensmaili
Aicha Bensmaili