Kang Cheng

Mr. Kang Cheng


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2023 in Electronics
Verified
Journal Article
Open access
PDF file
CSChunguang Suo
Chunguang Suo
KCKang Cheng
Kang Cheng
LWLifeng Wang
Lifeng Wang
ZWZhang Wenbin
Zhang Wenbin
XLXi Liu
Xi Liu
JZJunyu Zhu
Junyu Zhu
As one of the important parameters characterizing the cable’s operation status, an accurate measurement of the current is particularly important for the cable’s reliable operation and status monitoring. Aiming at the problem that the sum of the current phasors of multiphase cables is 0 when running in a steady state, and that the traditional mutual inductance current measurement method cannot be used for the phase current measurement of such cables, or that the insulation layer needs to be damaged, this paper proposes a non-contact measurement method of three-phase cable current, based on the magnetic field decoupling calculation. When combined with the actual parameters of the three-phase cable, the analytical calculation model of the magnetic field distribution of the three-phase cable is established. The relationship between the output ratio of the sensor and the deflection angle is obtained through theoretical derivation, the magnetic field coupling coefficient matrix is determined, and the transfer relationship between the output of the magnetic sensor and the current of each phase is clarified; an array magnetic field sensor is designed, which can sense the information of the adjacent magnetic field independently and is used for the reconstruction of three-phase currents. The effectiveness of the proposed method was tested on the built three-phase four-core cable current measurement test platform. The experimental results show that under the three-phase current balance, the measurement error of phase A, phase B and phase C is less than 2.8%, and the waveform and phase angle of the three-phase current can be well restored, which verifies the three-phase current measurement method proposed in this paper.

7 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ZWZhang Wenbin
Zhang Wenbin
YYYonglong Yang
Yonglong Yang
JZJingjing Zhao
Jingjing Zhao
RHRujin Huang
Rujin Huang
KCKang Cheng
Kang Cheng
MHMingxing He
Mingxing He
Traditional contact voltage measurement requires a direct electrical connection to the system, which is not easy to install and maintain. The voltage measurement based on the electric field coupling plate capacitance structure does not need to be in contact with the measured object or the ground, which can avoid the above problems. However, most of the existing flat-plate structure voltage measurement sensors are not only expensive to manufacture, but also bulky, and when the relative position between the wire under test and the sensor changes, it will bring great measurement errors, making it difficult to meet actual needs. Aiming to address the above problems, this paper proposes a multi-electrode array structure non-contact voltage sensor and signal processing algorithm. The sensor is manufactured by the PCB process, which effectively reduces the manufacturing cost and process difficulty. The experimental and simulation results show that, when the relative position of the wire and the sensor is offset by 10 mm in the 45° direction, the relative error of the traditional single-electrode voltage sensor is 17.62%, while the relative error of the multi-electrode voltage sensor designed in this paper is only 0.38%. In addition, the ratio error of the sensor under the condition of power frequency of 50 Hz is less than ±1% and the phase difference is less than 4°. The experimental results show that the sensor has good accuracy and linearity.

6 January 2023 in Electronics
Verified
Journal Article
Open access
PDF file
WZWenbin Zhang
Wenbin Zhang
RWRan Wei
Ran Wei
AJAerduoni Jiu
Aerduoni Jiu
KCKang Cheng
Kang Cheng
YYYonglong Yang
Yonglong Yang
CSChunguang Suo
Chunguang Suo
Realizing stable and reliable monitoring of a distribution network voltage environment can obtain real-time power parameter information and ensure the normal and safe operation of transmission lines, which is of great research significance and engineering value. Based on the distributed capacitance relationship between sensor and transmission line, an equivalent circuit capacitance voltage dividing model is proposed, and the relevant factors affecting the stability of the voltage dividing ratio are analyzed. The self-calibration principle of noncontact AC voltage measurement is proposed based on the system identification theory. The noncontact sensing structure is designed, a sensor probe prototype is fabricated, and a back-end conditioning circuit is designed to realize the overall measurement system. Finally, the validity of the measurement model is verified by simulation and experiment, and a measurement platform is built which proves the feasibility of the self-calibration method for noncontact voltage measurement. The experimental results show that the error is less than ±2%. This method can correctly restore the measured voltage waveform, has good linearity, and can realize wireless data transmission, which provides a new idea for the voltage measurement method of a distribution network.