At present, the method of using unmanned aerial vehicles (UAVs) with traditional navigation equipment for inspection of overhead transmission lines has the limitations of expensive sensors, difficult data processing, and vulnerable to weather and environmental factors, which cannot ensure the safety of UAV and power systems. Therefore, this paper establishes a mathematical model of spatial distribution of transmission lines to study the field strength distribution information around transmission lines. Based on this, research the navigation and positioning algorithm. The data collected by the positioning system are input into the mathematical model to complete the identification, positioning, and safety distance diagnosis of the field source. The detected data and processing results can provide reference for UAV obstacle avoidance navigation and safety warning. The experimental results show that the positioning effect of the positioning navigation algorithm is obvious, and the positioning error is within the range of use error and has good usability and application value.
Arc fault is an important cause of electrical fire. At present, the arc-fault detection method based on current and voltage is vulnerable to the influence of a nonlinear load and switching operation in the line, resulting in misjudgment and omission. Therefore, an arc-fault detection method based on the characteristics of electromagnetic radiation is proposed. A low-voltage AC series arc-fault simulation platform is built, and a simple annular antenna is designed to receive an electromagnetic radiation signal. It is proved by experiments that electromagnetic radiation signals have similar characteristic frequencies (13.6–14.2 MHz) under different currents, loads, arc positions and arc occurrence times. At the same time, the electromagnetic radiation signal of a low-voltage AC series arc and normal switching operations are compared. The pulse oscillation time of the radiation signals of the operating arc (2 μs) is far shorter than that of the faulty arc (4 μs), and the characteristic frequency of the radiation signal generated by the switching operation (9.35 MHz) is significantly lower than that of the series arc radiation signal (14 MHz). Compared with the existing methods, this method does not need to consider the influence of current, nonlinear load and other factors in the line, and can accurately distinguish the operating arc and faulty arc.
In order to prevent electric shock accidents during the maintenance and repair of high-voltage direct current (DC) live equipment, an intelligent safety early warning system device based on non-contact electric field measurement is developed in this paper, to ensure the life safety of electrical workers and the stable operation of equipment. Firstly, the self-developed electric field sensor is used to measure the electric field strength of the space around the charged device. The STM32 microprocessor in the sensor will compare the measured electric field value with a preset safety threshold. If the safety threshold is exceeded, the early warning device issues an audible alarm. It prompts the electric power operator to exit to a safe distance. In addition, the alarm prompt symbol and the real-time waveform of the measured electric field can be seen intuitively on the mobile smart APP interface. Secondly, for devices with different voltage levels, the sensor electric field measurement range and sensitivity can be dynamically adjusted by changing the motor speed. In addition, according to the voltage level identification algorithm, this is also to achieve an adaptive safety early warning of different live equipment. Finally, field experiments were performed at a ±500 kV DC converter station and an ±800 kV DC transmission line experimental platform. The measured values of the electric field are basically consistent with the simulated values, and the safety early warning device has no false positives or false negatives during the test. The experimental results show that the design of the safety warning device in this paper meets the actual needs, and it can alert the electric workers to the specified safety distance.
Disconnect switch and circuit breakers operations in gas insulated switchgear (GIS) systems may produce very fast transient overvoltage (VFTO). Detecting VFTO is the first step for researchers to reduce the damage to other equipment of the substation caused by VFTO. Most of the existing sensors used for VFTO are generally bulky, complex to install, and require modification of the GIS structure. In this paper, a miniaturized measurement system that uses capacitive voltage divider and differentiating–integrating circuit is proposed. A special sensor structure and optimized differentiating–integrating circuit components arrangement were designed to increase the bandwidth of the measurement system. The frequency-domain, time-domain and voltage divide calibration experiment was performed, and a comparison experiment with an internal VFTO sensor was conducted. The measurement system was applied in the 500 kV GIS substation, and the VFTO measurement under specific conditions was carried out. The measured time domain and frequency domain waveforms conformed to the definition of standard VFTO according to IEC 60,071. It was found that the proposed measurement system meets VFTO measurement requirements and can be applied to actual VFTO measurements.
Noncontact voltage measurement has the advantages of simple handling, high construction safety, and not being affected by line insulation. However, in practical measurement of noncontact voltage, sensor gain is affected by wire diameter, wire insulation material, and relative position deviation. At the same time, it is also subject to interference from interphase or peripheral coupling electric fields. This paper proposes a noncontact voltage measurement self-calibration method based on dynamic capacitance, which realizes self-calibration of sensor gain through unknown line voltage to be measured. Firstly, the basic principle of the self-calibration method for noncontact voltage measurement based on dynamic capacitance is introduced. Subsequently, the sensor model and parameters were optimized through error analysis and simulation research. Based on this, a sensor prototype and remote dynamic capacitance control unit that can shield against interference are developed. Finally, the accuracy test, anti-interference ability test, and line adaptability test of the sensor prototype were conducted. The accuracy test showed that the maximum relative error of voltage amplitude was 0.89%, and the phase relative error was 1.57%. The anti-interference ability test showed that the error offset was 0.25% when there were interference sources. The line adaptability test shows that the maximum relative error in testing different types of lines is 1.01%.
In view of the fact that the partial discharge (PD) signal energy is mainly concentrated below hundreds of megahertz, the ultra-high frequency part of the energy is weak, and the interior space of the switchgear is narrow, this paper proposes a new method for PD detection of the switchgear based on near-field detection. Firstly, based on the principle of PD, the field characteristics of the signal in the switchgear are analyzed. After that, the probe is designed with an electric small loop structure. Based on its equivalent circuit, its measurement principle and amplitude frequency characteristics are analyzed. The influence of probe size and material on amplitude frequency characteristics is obtained by using simulation software High Frequency Structure Simulator (HFSS), and the probe parameters suitable for PD detection in the switchgear are determined. Finally, the performance of the probe is measured by network analyzer, and the PD signal is tested on the simulated PD test platform. The results show that the probe works in the frequency band of 10–200 MHz and can receive PD signals containing more energy information. In the operating frequency band, the reflection coefficient of the probe port is very large, and its interference to the signal near field is particularly small. The probe also has good frequency response characteristics, and the fluctuation in the frequency band is less than 5 dB, which can obtain more accurate PD signal characteristics in subsequent processing. In addition, the probe is passive, with dimensions of 166 mm in length, 104 mm in width, and 2 mm in thickness, which is suitable for placing in the switchgear with small internal space. The results of PD receiving test show that the probe can reflect the occurrence of PD remarkably and accurately.