Zhang Wenbin

Dr. Zhang Wenbin


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
CSChunguang Suo
Chunguang Suo
RHRujin Huang
Rujin Huang
GZGuoqiong Zhou
Guoqiong Zhou
ZWZhang Wenbin
Zhang Wenbin
YWyanyun wang
yanyun wang
MHMingxing He
Mingxing He
Noncontact voltage measurement has the advantages of simple handling, high construction safety, and not being affected by line insulation. However, in practical measurement of noncontact voltage, sensor gain is affected by wire diameter, wire insulation material, and relative position deviation. At the same time, it is also subject to interference from interphase or peripheral coupling electric fields. This paper proposes a noncontact voltage measurement self-calibration method based on dynamic capacitance, which realizes self-calibration of sensor gain through unknown line voltage to be measured. Firstly, the basic principle of the self-calibration method for noncontact voltage measurement based on dynamic capacitance is introduced. Subsequently, the sensor model and parameters were optimized through error analysis and simulation research. Based on this, a sensor prototype and remote dynamic capacitance control unit that can shield against interference are developed. Finally, the accuracy test, anti-interference ability test, and line adaptability test of the sensor prototype were conducted. The accuracy test showed that the maximum relative error of voltage amplitude was 0.89%, and the phase relative error was 1.57%. The anti-interference ability test showed that the error offset was 0.25% when there were interference sources. The line adaptability test shows that the maximum relative error in testing different types of lines is 1.01%.

1 June 2016 in Integrated Ferroelectrics
Verified
Journal Article
Closed access
ZWZhang Wenbin
Zhang Wenbin
XTXiangyu Tan
Xiangyu Tan
KWKe Wang
Ke Wang
TLTianwen Li
Tianwen Li
JCJunhua Chen
Junhua Chen
The accurate mathematical model of converter is very important in the process of designing high performance switch power. Nonlinear, multimodal and time-varying are the characteristics of the DC-DC converter. So it is necessary to study it in a new way. This paper presents a mathematical model of Boost converter circuit by state space average method. The closed-loop PI controller based on the Boost converter model was designed. The static and dynamic performance of the closed-loop system was tested in Simulink which demonstrated a good behavior of the system to meet the requirements of user.

17 March 2023 in Electronics
Verified
Journal Article
Open access
PDF file
CSChunguang Suo
Chunguang Suo
KCKang Cheng
Kang Cheng
LWLifeng Wang
Lifeng Wang
ZWZhang Wenbin
Zhang Wenbin
XLXi Liu
Xi Liu
JZJunyu Zhu
Junyu Zhu
As one of the important parameters characterizing the cable’s operation status, an accurate measurement of the current is particularly important for the cable’s reliable operation and status monitoring. Aiming at the problem that the sum of the current phasors of multiphase cables is 0 when running in a steady state, and that the traditional mutual inductance current measurement method cannot be used for the phase current measurement of such cables, or that the insulation layer needs to be damaged, this paper proposes a non-contact measurement method of three-phase cable current, based on the magnetic field decoupling calculation. When combined with the actual parameters of the three-phase cable, the analytical calculation model of the magnetic field distribution of the three-phase cable is established. The relationship between the output ratio of the sensor and the deflection angle is obtained through theoretical derivation, the magnetic field coupling coefficient matrix is determined, and the transfer relationship between the output of the magnetic sensor and the current of each phase is clarified; an array magnetic field sensor is designed, which can sense the information of the adjacent magnetic field independently and is used for the reconstruction of three-phase currents. The effectiveness of the proposed method was tested on the built three-phase four-core cable current measurement test platform. The experimental results show that under the three-phase current balance, the measurement error of phase A, phase B and phase C is less than 2.8%, and the waveform and phase angle of the three-phase current can be well restored, which verifies the three-phase current measurement method proposed in this paper.

14 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
XTXiangyu Tan
Xiangyu Tan
WLWenyun Li
Wenyun Li
GQGuochao Qian
Guochao Qian
GAGang Ao
Gang Ao
XXXiaowei Xu
Xiaowei Xu
ZWZhang Wenbin
Zhang Wenbin
According to the requirements of weak current measurement in power grid, a weak current sensor with anti-low frequency interference ability is developed. The sensor adopts the principle of fluxgate detection and adds a magnetic ring on the original basis. The structure of the magnetic ring is simulated using comsol to further improve detection sensitivity. In order to solve the problem that the electromagnetic current sensor is vulnerable to the interference of geomagnetic field and power frequency magnetic field in weak current measurement, a magnetic shielding method with low cost is selected, and the shielding shell structure is designed using a finite element analysis method. The experimental results show that the minimum measurable current is 1 mA, the measurement range is 1 mA–1 A, and the bandwidth is DC-16 kHz. The designed magnetic shielding shell can effectively reduce 97.3% of the DC magnetic field interference and 95.7% of the power frequency magnetic field interference. The sensor can realize accurate measurement of weak current in power grid.

1 January 2018 in Integrated Ferroelectrics
Verified
Journal Article
Closed access
ZWZhang Wenbin
Zhang Wenbin
WBWenhao Bai
Wenhao Bai
JWJinyan Wang
Jinyan Wang
LZLei Zhao
Lei Zhao
CMChuxia Ma
Chuxia Ma
Aiming at the problem that the transformer substation intelligent detection of vehicles in the process of moving away from the planning path, based on the four-wheel model vehicle, this paper proposes a fuzzy adaptive PID path tracking control method based on optimal lateral deviation. Firstly, the kinematic model and the equation of the linear 2-DOF of the vehicle are established by taking the front wheel steering angle of the model vehicle as the input of the control system. Secondly, the linear quadratic regulator (LQR) is introduced to minimize the transverse tracking error between the model vehicle and the expected path. Finally, the control parameters of the fuzzy PID are updated with the lateral deviation and the variation rate of the deviation, and the front wheel steering angle of the Vehicle is adjusted adaptively to realize the stable tracking of the desired path. The simulation results show that the tracking error of the proposed path tracking control method is concentrated between -0.08m and +0.08m, and the desired path can be better tracked.

24 October 2022 in Electronics
Verified
Journal Article
Open access
PDF file
NZNianrong Zhou
Nianrong Zhou
JLJian Li
Jian Li
ZWZhang Wenbin
Zhang Wenbin
JZJiawen Zhao
Jiawen Zhao
JZJingjing Zhao
Jingjing Zhao
With the increasing scale of transmission lines, drone inspection has become a major method of transmission line inspection. In the process of UAV inspection, the safety distance warning of UAV and transmission lines is crucial, and the existing UAV safety distance warning methods have difficulties, such as high cost, low environmental adaptability, and data processing. In this paper, we propose a safety distance warning method based on the rate of change of electric field ring ratio, which can be applied to the inspection process of transmission lines of different voltage levels. In order to accurately measure the electric field strength around the transmission lines, a three-dimensional electric field measurement system for measuring the electric field in space is designed in this paper. Finally, a 10 kV three-phase transmission line experimental platform was built to verify the feasibility of the method proposed in this paper.