Recently, considerable work has been directed at the development of an ultracompact X-ray free-electron laser (UCXFEL) based on emerging techniques in high-field cryogenic acceleration, with attendant dramatic improvements in electron beam brightness and state-of-the-art concepts in beam dynamics, magnetic undulators, and X-ray optics. A full conceptual design of a 1 nm (1.24 keV) UCXFEL with a length and cost over an order of magnitude below current X-ray free-electron lasers (XFELs) has resulted from this effort. This instrument has been developed with an emphasis on permitting exploratory scientific research in a wide variety of fields in a university setting. Concurrently, compact FELs are being vigorously developed for use as instruments to enable next-generation chip manufacturing through use as a high-flux, few nm lithography source. This new role suggests consideration of XFELs to urgently address emerging demands in the semiconductor device sector, as identified by recent national need studies, for new radiation sources aimed at chip manufacturing. Indeed, it has been shown that one may use coherent X-rays to perform 10–20 nm class resolution surveys of macroscopic, cm scale structures such as chips, using ptychographic laminography techniques. As the XFEL is a very promising candidate for realizing such methods, we present here an analysis of the issues and likely solutions associated with extending the UCXFEL to harder X-rays (above 7 keV), much higher fluxes, and increased levels of coherence, as well as methods of applying such a source for ptychographic laminography to microelectronic device measurements. We discuss the development path to move the concept to rapid realization of a transformative XFEL-based application, outlining both FEL and metrology system challenges.
In this paper, we illustrate the RF design and measurements of a C-band prototype structure for an Ultra High Dose Rate medical linac. (1) Background: FLASH Radiotherapy (RT) is a revolutionary new technique for cancer cure. It releases ultra-high radiation dose rates (above 100 Gy/s) in microsecond short pulses. In order to obtain a high dose in a very short time, accelerators with high-intensity currents (the order of 100 mA peak currents) have to be developed. In this contest, Sapienza University, in collaboration with SIT-Sordina IORT Technology spa, is developing a new C-band linac to achieve the FLASH regime. (2) Methods: We performed the RF electromagnetic design of the prototype of the C band linac using CST STUDIO Suite Code and the RF low power RF test at Sapienza University of Rome. The measurements of the field in the cavity have been done with the bead-pull technique. (3) Results: This device is a nine-cell structure operating on the mode at 5.712 GHz (C-band). We report and discuss the test measurement results on a full-scale copper prototype, showing good agreement with CST RF simulations. A tuning procedure has been implemented in order to ensure proper operating frequency and to reach a field profile flatness of the order of a few percent. (4) Conclusions: The prototype of a C-band linac for FLASH applications was successfully tested with low RF power at Sapienza University. The fabrication and ad hoc tuning procedures have been optimized and discussed in the paper.
23 August 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Recently, considerable work has been directed at development of a ultra-compact X-ray free-electron laser based on emerging techniques in high field cryogenic acceleration, with attendant dramatic improvements in electron beam brightness, and state-of-the-art concepts in beam dynamics, magnetic undulators, and X-ray optics. A full conceptual design of a 1 nm XFEL with a length and cost over an order of magnitude below current XFELs has resulted from this effort. This instrument has been developed with an emphasis on permitting exploratory scientific research in a wide variety of fields in a university setting. Concurrently, compact FELs are being urgently developed for use as an instrument to enable next generation chip manufacturing through use as a high flux, few-nm lithography source. This new role suggests consideration of XFELs to addressed urgently emerging demands in this sector, as identified by recent national need studies, for new radiation sources aimed at chip manufacturing: a coherent hard X-ray source which enables frontier metrology methods. Indeed, it has been shown that one may use coherent X-rays to perform 10 nm-class resolution surveys of macroscopic, cm-scale structures such as chips, using ptychographic laminography. As the XFEL is a very promising candidate for realizing such methods, we present here an analysis of the issues and likely solutions associated with extending the UCXFEL to harder X-rays (above 7 keV), much higher fluxes and levels of coherence, and methods of applying such a source for ptychographic laminography to micro-electronic device measurements. We discuss the development path to move the concept to rapid realization of a transformative FEL-based application, outlining FEL and metrology system challenges.
Particle-driven plasma wakefield acceleration (PWFA) exploits the intense wakefields excited in a plasma by a high-brightness driver beam in order to accelerate a trailing, properly delayed witness electron beam. Such a configuration offers notable advantages in achieving very large accelerating gradients that are suitable for applications in particle colliders and photon production. Moreover, the amplitude of the accelerating fields can be enhanced by resonantly exciting the plasma using a multi-pulse driver beam with a proper time structure. Before the injection into the plasma stage, the pulsed electron beam, conventionally termed the comb beam, is usually produced and pre-accelerated in a radio-frequency (RF) linear accelerator (linac). In this pape, we discuss challenging aspects of the dynamics that comb beams encounter in the RF injector stage preceding the plasma. In particular, the examples we analyze focus on the use of velocity bunching to manipulate the time structure of the beam and the impact of dipole short-range wakefields on the transverse emittances. Indeed, both processes crucially affect the phase space distribution and its quality, which are determinant features for an efficient acceleration in the plasma. In addition, the analyses we present are performed with the custom tracking code MILES, which utilizes semi-analytical models for a simplified evaluation of wakefield effects in the presence of space charge forces.