lucia giuliano

Dr. lucia giuliano

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2022 in Physica Medica
Verified
Journal Article
Closed access
LFLuigi Faillace
Luigi Faillace
DAD. Alesini
D. Alesini
GBG. Bisogni
G. Bisogni
FBFabio Bosco
Fabio Bosco
MCM. Carillo
M. Carillo
LGlucia giuliano
lucia giuliano

3 January 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LGlucia giuliano
lucia giuliano
GFGaia Franciosini
Gaia Franciosini
Luigi PalumboLuigi Palumbo
Luigi Palumbo
LALilia Aggar
Lilia Aggar
Marie DutreixMarie Dutreix
Marie Dutreix
SHSophie Heinrich
Sophie Heinrich
Purpose: The electron linac ElectronFlash installed at Institut Curie (Orsay, France) is entirely dedicated to FLASH irradiation for radiobiological and pre-clinical studies. The system was designed to deliver an ultra-high-dose rate per pulse (UHDR) (above 106 Gy/s) and a very high average dose rate at different energies and pulse durations. A campaign of tests and measurements was performed to obtain a full reliable characterizations of the electron beam and of the delivered dose, which are necessary to the radiobiological experiments. Methods: A Faraday cup was used to measure the electron charges in a single RF pulse. The percentage depth dose (PDD) and the transverse dose profiles, at the energies of 5 MeV and 7 MeV, were evaluated employing Gafchromic films EBT-XD for two Poly-methylmethacrylate (PMMA) applicators with irradiation sizes of 30 mm and 120 mm, normally used for in vivo and in vitro experiments, respectively. The results were compared with Monte Carlo (MC) simulations. Results: The measurements were performed during a period of a few months in which the experimental set up was adapted and tuned in order to characterize the electron beam parameters and the values of delivered doses before the radiobiological experiments. The measurements showed that the dose parameters, obtained at the energy of 5 MeV and 7 MeV with different applicators, fulfill the FLASH regime, with a maximum value of an average dose rate of 4750 Gy/s, a maximum dose per pulse of 19 Gy and an instantaneous dose rate up to 4.75 ×106 Gy/s. By means of the PMMA applicators, a very good flatness of the dose profiles was obtained at the cost of a reduced total current. The flatness of the large field is reliable and reproducible in radiobiological experiments. The measured PDD and dose profiles are in good agreement with Monte Carlo simulations with more than 95% of the gamma-index under the thresholds of 3 mm/3%. Conclusions: The results show that the system can provide UHDR pulses totally satisfying the FLASH requirements with very good performances in terms of beam profile flatness for any size of the fields. The monitoring of electron beams and the measurement of the dose parameters played an important role in the in vivo and in vitro irradiation experiments performed at the Institut Curie laboratory.

17 May 2021 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
LFLuigi Faillace
Luigi Faillace
SBS. Barone
S. Barone
GBGiuseppe Battistoni
Giuseppe Battistoni
MFM. Di Francesco
M. Di Francesco
GFGiuseppe Felici
Giuseppe Felici
MMM. Migliorati
M. Migliorati
Radiation therapy is currently the most utilized technique for the treatment of tumors by means of ionizing radiation, such as electrons, protons and x/gamma rays, depending on the type, size and depth of the cancer mass. Radiation therapy has in general fulfilled the main requirement of targeting thus damaging the malignant cells and sparing the healthy tissues as best as possible. In this scenario, electron linear accelerators have been operated as viable tools for the delivery of both high-energetic electrons and x-ray beams, which are obtained via the bremsstrahlung process of the electrons hitting on a high-Z material. Recently, it has been experimentally demonstrated that ultrahigh dose-rate bursts of electrons and x-ray beams increase the differential response between healthy and tumor tissues. This beneficial response is referred to as the FLASH effect. For this purpose, we have developed the first dedicated compact S-band linear accelerator for FLASH radiotherapy. This linac is optimized for a nominal energy of 7 MeV and a pulsed electron beam current of 100 mA and above. The accelerator is mounted on a remote-controlled system for preclinical research studies in the FLASH regime. We will show the rf and beam dynamics design of the S-band linac as well as the commissioning and high-power rf tests. Furthermore, the results of the dosimetric measurements will be illustrated.

3 June 2022 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
LFLuigi Faillace
Luigi Faillace
RAR. Agustsson
R. Agustsson
Mostafa BehtoueiMostafa Behtouei
Mostafa Behtouei
FBF. Bosco
F. Bosco
DBD. Bruhwiler
D. Bruhwiler
James RosenzweigJames Rosenzweig
James Rosenzweig
The production of high spectral brilliance radiation from electron beam sources depends critically on the electron beam qualities. One must obtain very high electron beam brightness, implying simultaneous high peak current and low emittance. These attributes are enabled through the use of very high field acceleration in a radio-frequency (rf) photoinjector source. Despite the high fields currently utilized, there is a limit on the achievable peak current in high brightness operation, in the range of tens of Ampere. This limitation can be overcome by the use of a hybrid standing wave/traveling wave structure; the standing wave portion provides acceleration at a high field from the photocathode, while the traveling wave part yields strong velocity bunching. This approach is explored here in a C-band scenario, at field strengths (>100  MV/m) at the current state-of-the-art. It is found that one may arrive at an electron beam with many hundreds of Amperes with well-sub-micron normalized emittance. This extremely compact injector system also possesses attractive simplification of the rf distribution system by eliminating the need for an rf circulator. We explore the use of this device in a compact 400 MeV-class source, driving both inverse Compton scattering and free-electron laser radiation sources with unique, attractive properties.

11 October 2023 in Cells
Verified
Journal Article
Open access
PDF file
MDMaxime Dubail
Maxime Dubail
SHSophie Heinrich
Sophie Heinrich
LPLucie Portier
Lucie Portier
JBJessica Bastian
Jessica Bastian
LGlucia giuliano
lucia giuliano
CFCharles Fouillade
Charles Fouillade
To rapidly assess healthy tissue toxicities induced by new anti-cancer therapies (i.e., radiation alone or in combination with drugs), there is a critical need for relevant and easy-to-use models. Consistent with the ethical desire to reduce the use of animals in medical research, we propose to monitor lung toxicity using an ex vivo model. Briefly, freshly prepared organotypic lung slices from mice were irradiated, with or without being previously exposed to chemotherapy, and treatment toxicity was evaluated by analysis of cell division and viability of the slices. When exposed to different doses of radiation, this ex vivo model showed a dose-dependent decrease in cell division and viability. Interestingly, monitoring cell division was sensitive enough to detect a sparing effect induced by FLASH radiotherapy as well as the effect of combined treatment. Altogether, the organotypic lung slices can be used as a screening platform to rapidly determine in a quantitative manner the level of lung toxicity induced by different treatments alone or in combination with chemotherapy while drastically reducing the number of animals. Translated to human lung samples, this ex vivo assay could serve as an innovative method to investigate patients’ sensitivity to radiation and drugs.

22 February 2023 in Instruments
Verified
Journal Article
Open access
PDF file
LGlucia giuliano
lucia giuliano
FBFabio Bosco
Fabio Bosco
MCMartina Carillo
Martina Carillo
GFGiuseppe Felici
Giuseppe Felici
LFLuca Ficcadenti
Luca Ficcadenti
LFLuigi Faillace
Luigi Faillace
In this paper, we illustrate the RF design and measurements of a C-band prototype structure for an Ultra High Dose Rate medical linac. (1) Background: FLASH Radiotherapy (RT) is a revolutionary new technique for cancer cure. It releases ultra-high radiation dose rates (above 100 Gy/s) in microsecond short pulses. In order to obtain a high dose in a very short time, accelerators with high-intensity currents (the order of 100 mA peak currents) have to be developed. In this contest, Sapienza University, in collaboration with SIT-Sordina IORT Technology spa, is developing a new C-band linac to achieve the FLASH regime. (2) Methods: We performed the RF electromagnetic design of the prototype of the C band linac using CST STUDIO Suite Code and the RF low power RF test at Sapienza University of Rome. The measurements of the field in the cavity have been done with the bead-pull technique. (3) Results: This device is a nine-cell structure operating on the π/2 mode at 5.712 GHz (C-band). We report and discuss the test measurement results on a full-scale copper prototype, showing good agreement with CST RF simulations. A tuning procedure has been implemented in order to ensure proper operating frequency and to reach a field profile flatness of the order of a few percent. (4) Conclusions: The prototype of a C-band linac for FLASH applications was successfully tested with low RF power at Sapienza University. The fabrication and ad hoc tuning procedures have been optimized and discussed in the paper.