Mohamed Choukairi

Prof. Dr. Mohamed Choukairi


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2024 in Talanta
Verified
Journal Article
Closed access
Mohamed ACHACHEMohamed ACHACHE
Mohamed ACHACHE
GIGhizlane Elouilali Idrissi
Ghizlane Elouilali Idrissi
Anas ChrakaAnas Chraka
Anas Chraka
NSNordin Ben Seddik
Nordin Ben Seddik
KDKhalid Draoui
Khalid Draoui
MCMohamed Choukairi
Mohamed Choukairi

13 May 2024 in Microchemical Journal
Verified
Journal Article
Closed access
Mohamed ACHACHEMohamed ACHACHE
Mohamed ACHACHE
GIGhizlane Elouilali Idrissi
Ghizlane Elouilali Idrissi
NSNordin Ben Seddik
Nordin Ben Seddik
SBSoumia El Boumlasy
Soumia El Boumlasy
IKIman Kouda
Iman Kouda
MCMohamed Choukairi
Mohamed Choukairi

1 February 2023 in ChemistryOpen
Verified
Journal Article
Open access
MCMohamed Choukairi
Mohamed Choukairi
DBDounia Bouchta
Dounia Bouchta
LBLoubna Bounab
Loubna Bounab
Elisa González-RomeroElisa González-Romero
Elisa González-Romero
Mohamed ACHACHEMohamed ACHACHE
Mohamed ACHACHE
MGMouad Gharous
Mouad Gharous
A novel modification of a paste carbon electrode by Bentonite (Bent) and l‐Cysteine (l‐Cyst) was carried out for uric acid (UA) and ascorbic acid (AA) detection and quantification. Morphological and compositional characterization of the electrode surface were carried out using electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM) and energy dispersive X‐ray spectroscopic analysis (EDS). Cyclic voltammetry (CV) and square wave voltammetry (SWV) techniques were used to analyze UA and AA. The obtained sensor shows a good stability, sensibility, selectivity, and regeneration ability. Accordingly, the limit of detection (LOD) is found to be 0.031 μm and 9.6 μm for UA and AA, respectively. A good linearity in the range of 0.1 to 100 μm for UA and 10 to 1000 μm for AA was obtained. The peak‐to‐peak separation of UA‐AA (ΔEUA‐AA) was determined to be 330 mV. In addition, the sensor is applied successfully to monitor UA and AA in serum samples.


11 May 2024 in Talanta
Verified
Journal Article
Closed access
MCMohamed Choukairi
Mohamed Choukairi
LHLamia Hejji
Lamia Hejji
Mohamed ACHACHEMohamed ACHACHE
Mohamed ACHACHE
MTM'HAmed Touil
M'HAmed Touil
DBDounia Bouchta
Dounia Bouchta
AAAbdelmonaim Azzouz
Abdelmonaim Azzouz

Verified
Journal Article
Open access
PDF file
MGMoaad GHAROUS
Moaad GHAROUS
LBLoubna Bounab
Loubna Bounab
FPFernando J. Pereira
Fernando J. Pereira
MCMohamed Choukairi
Mohamed Choukairi
RLRoberto López
Roberto López
AAA.-Javier Aller
A.-Javier Aller
Paracetamol (PCT), or acetaminophen, is an important drug used worldwide for various clinical purposes. However, the excessive or indiscriminate use of PCT can provoke liver and kidney dysfunction; hence, it is essential to determine the amount of this target in biological samples. In this work, we develop a quick, simple, and sensitive voltammetric method using chemically modified electrodes to determine PCT in complex matrices, including human serum and commercial solid formulations. We modify the carbon paste electrode with stevensite monoclinic clay mineral (Stv-CPE), using cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy to characterise and detect PCT. The kinetics study provides a better electrochemical characterisation of the electrode behaviour, finding the detection and quantitation limits of 0.2 μM and 0.5 μM under favourable conditions. Further, the best linear working concentration range is 0.6–100 μM for PCT, applying the proposed method to the quantitative determination of PCT content in reference tablet formulations and biological samples for validation.