Ketan Pancholi

Dr. Ketan Pancholi

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2021 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
RGRanjeetkumar Gupta
Ranjeetkumar Gupta
DMDaniel Mitchell
Daniel Mitchell
JBJamie Blanche
Jamie Blanche
SHSam Harper
Sam Harper
WTWenshuo Tang
Wenshuo Tang
David FlynnDavid Flynn
David Flynn
The growing demand and diversity in the application of industrial composites and the current inability of present non-destructive evaluation (NDE) methods to perform detailed inspection of these composites has motivated this comprehensive review of sensing technologies. NDE has the potential to be a versatile tool for maintaining composite structures deployed in hazardous and inaccessible areas, such as offshore wind farms and nuclear power plants. Therefore, the future composite solutions need to take into consideration the niche requirements of these high-value/critical applications. Composite materials are intrinsically complex due to their anisotropic and non-homogeneous characteristics. This presents a significant challenge for evaluation and the associated data analysis for NDEs. For example, the quality assurance, certification of composite structures, and early detection of the failure is complex due to the variability and tolerances involved in the composite manufacturing. Adapting existing NDE methods to detect and locate the defects at multiple length scales in the complex materials represents a significant challenge, resulting in a delayed and incorrect diagnosis of the structural health. This paper presents a comprehensive review of the NDE techniques, that includes a detailed discussion of their working principles, setup, advantages, limitations, and usage level for the structural composites. A comparison between these techniques is also presented, providing an insight into the future trends for composites’ prognostic and health management (PHM). Current research trends show the emergence of the non-contact-type NDE (including digital image correlation, infrared tomography, as well as disruptive frequency-modulated continuous wave techniques) for structural composites, and the reasons for their choice over the most popular contact-type (ultrasonic, acoustic, and piezoelectric testing) NDE methods is also discussed. The analysis of this new sensing modality for composites’ is presented within the context of the state-of-the-art and projected future requirements.

9 October 2019 in Frontiers in Materials
Verified
Journal Article
Open access
PDF file
JKJohn Keyte
John Keyte
KPKetan Pancholi
Ketan Pancholi
JNJames Njuguna
James Njuguna
The two-dimensional macro molecule graphene and its derivatives have widely been investigated for their application as nanofiller in carbon fiber-reinforced composites (CFRC). Research has progressed from techniques that disperse graphene as a mixing constituent within the composite material to more complex examples where graphene is covalently bonded to fiber, matrix or both via multiple reaction steps. This field of research is multi-disciplinary whereby branches of materials, engineering, polymer science, physics and chemistry often overlap. From the materials engineering perspective, the desire is to discover the novel materials targeting industrial applications and obtain a full understanding of the graphene oxide chemistry and interaction of graphene oxide with a polymer matrix. To date, most of the research is targeted at (i) improving the fiber/matrix interface properties and/or (ii) improving the dispersion of nanofiller within the matrix; both factors ultimately improve composite performance. Organizing that information critically can lead to emergence of a generalization of material design. Therefore, the objective of this work is to critically review current state of art in the field of graphene oxide/epoxy CFRCs and propose the design rules based on current scientific trend and common themes for future works.

9 August 2007 in European Biophysics Journal
Verified
Journal Article
Closed access
PDF file
KPKetan Pancholi
Ketan Pancholi
UFU. Farook
U. Farook
RMR. Moaleji
R. Moaleji
ESEleanor Stride
Eleanor Stride
Mohan EdirisingheMohan Edirisinghe
Mohan Edirisinghe

11 March 2008 in Langmuir
Verified
Journal Article
Closed access
KPKetan Pancholi
Ketan Pancholi
ESEleanor Stride
Eleanor Stride
MEMohan Edirisinghe
Mohan Edirisinghe

19 February 2008 in Journal of The Royal Society Interface
Verified
Journal Article
Closed access
ESEleanor Stride
Eleanor Stride
KPKetan Pancholi
Ketan Pancholi
MEM.J Edirisinghe
M.J Edirisinghe
SSS Samarasinghe
S Samarasinghe
The nonlinear response of gas bubbles to acoustic excitation is an important phenomenon in both the biomedical and engineering sciences. In medical ultrasound imaging, for example, microbubbles are used as contrast agents on account of their ability to scatter ultrasound nonlinearly. Increasing the degree of nonlinearity, however, normally requires an increase in the amplitude of excitation, which may also result in violent behaviour such as inertial cavitation and bubble fragmentation. These effects may be highly undesirable, particularly in biomedical applications, and the aim of this work was to investigate alternative means of enhancing nonlinear behaviour. In this preliminary report, it is shown through theoretical simulation and experimental verification that depositing nanoparticles on the surface of a bubble increases the nonlinear character of its response significantly at low excitation amplitudes. This is due to the fact that close packing of the nanoparticles restricts bubble compression.

21 May 2015 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Open access
PDF file
Dehong HuoDehong Huo
Dehong Huo
CLChao Lin
Chao Lin
ZCZi Jie Choong
Zi Jie Choong
KPKetan Pancholi
Ketan Pancholi
Patrick A G DegenaarPatrick A G Degenaar
Patrick A G Degenaar
This paper presents an experimental investigation on surface and subsurface characterisation of micro-machined single-crystal silicon with (100) orientation. Full immersion slot milling was conducted using solid cubic boron nitride (CBN) and diamond-coated fine grain tungsten carbide micro-end mills with a uniform tool diameter of 0.5 mm. The micro-machining experiments were carried out on an ultra-precision micro-machining centre. Formal design of experiments (DoE) techniques were applied to design and analysis of the machining process. Surface roughness, edge chipping formation and subsurface residual stress under varying machining conditions were characterised using white light interferometry, SEM and Raman microspectroscopy. Tens of nanometre-level surface roughness can be achieved under the certain machining conditions, and influences of variation of cutting parameters including cutting speeds, feedrate and axial depth of cut on surface roughness were analysed using analysis of variance (ANOVA) method. Raman microspectroscopy studies show that compressive subsurface residual stress and amorphous phase transformation were observed on most of the micro-machined subsurface, which provides evidence of ductile mode cutting. Surface and subsurface characterisation studies show that the primary material removal mode is ductile or partial ductile using lower feedrate for both tools, and diamond-coated tools can produce better surface quality. Silicon brain implants were fabricated with good dimensional accuracy and edge quality using the optimised machining conditions, which demonstrated that micro-milling is an effective process for fabrication of silicon components at a few tens to a few hundreds of micron scale.