Amir Hossein Nejat

Dr. Amir Hossein Nejat


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
MEMajid Eshghpour
Majid Eshghpour
PDParisa Dastmalchi
Parisa Dastmalchi
ANAmir Hossein Nekooei
Amir Hossein Nekooei
ANAmir Hossein Nejat
Amir Hossein Nejat

1 November 2014 in International Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
RSR. Shahakbari
R. Shahakbari
MEM. Eshghpour
M. Eshghpour
ARA. Rajaei
A. Rajaei
NRNaser Rezaei
Naser Rezaei
PGP. Golfakhrabadi
P. Golfakhrabadi
ANAmir Hossein Nejat
Amir Hossein Nejat


13 September 2023 in Polymers
Verified
Journal Article
Open access
PDF file
JPJorge Palavicini
Jorge Palavicini
SQSherrod L. Quin
Sherrod L. Quin
WZWael Zakkour
Wael Zakkour
KZKarim Zakkour
Karim Zakkour
SVSafa Manafi Varkiani
Safa Manafi Varkiani
ANAmir Hossein Nejat
Amir Hossein Nejat
(1) Purpose: The aim of the present study was to compare the bond strength between two 3D-printed resins designed for long-term provisional crowns and three different reline materials. (2) Materials and Methods: Rectangular specimens were prepared from two 3D-printed resins (Envision Tech and NextDent C&B) and a conventional self-cure PMMA. Transparent tubes filled with three different reline materials including composite resin, Bis-acryl, and PMMA were bonded to the 3D-printed specimens (n = 11 per group, total of 6 study groups). Tubes filled with PMMA were bonded to the prepared PMMA specimens which served as the control group (n = 11, control group). The specimens were subjected to a shear bond strength (SBS) test, and mode of failure was recorded using light microscopy. Statistical analysis was performed using a one-way ANOVA and post hoc Tukey’s tests (alpha = 0.05). (3) Results: The highest SBS value was achieved to both 3D-printed materials with the PMMA reline material. The bond to both 3D-printed materials was lower with Bis-acrylic or composite resin relines in comparison to that with PMMA (p-value < 0.05). No significant difference was found between the control PMMA group and either 3D-printed material when relined with PMMA (p-value > 0.05). (4) Conclusion: The tested 3D-printed resins achieved a clinically acceptable bond strength when relined with PMMA.

28 February 2024 in Materials
Verified
Journal Article
Open access
PDF file
AAAkram Sayed Ahmed
Akram Sayed Ahmed
NLNathaniel Lawson
Nathaniel Lawson
CFChin-Chuan Fu
Chin-Chuan Fu
Pranit V BoraPranit V Bora
Pranit V Bora
EKEdwin Kee
Edwin Kee
ANAmir Hossein Nejat
Amir Hossein Nejat
Background: Determination of the eligibility of several tooth analog materials for use in crown fracture testing. Methods: A standardized premolar crown preparation was replicated into three types of resin dies (C&B, low modulus 3D printed resin; OnX, high modulus 3D printed resin composite; and highest modulus milled resin composite). 0.8 mm zirconia crowns were bonded to the dies and the maximum fracture load of the crowns was tested. Twelve extracted human premolars were prepared to a standardized crown preparation, and duplicate dies of the prepared teeth were 3D printed out of C&B. Zirconia crowns were bonded to both the dies and natural teeth, and their fracture load was tested. Results: There was no statistical difference between the fracture load of zirconia crowns bonded to standardized dies of C&B (1084.5 ± 134.2 N), OnX (1112.7 ± 109.8 N) or Lava Ultimate (1137.5 ± 88.7 N) (p = 0.580). There was no statistical difference between the fracture load of crowns bonded to dentin dies (1313 ± 240 N) and a 3D-printed resin die (C&B, 1156 ± 163 N) (p = 0.618). Conclusions: There was no difference in the static fracture load of zirconia crowns bonded to standardized resin dies with different moduli or between a low modulus resin die and natural dentin die.

3 December 2024 in Dental Clinics of North America
Verified
Journal Article
Closed access
ANAmir Hossein Nejat
Amir Hossein Nejat