David Wurm

Dr. David Wurm

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2021 in Nature Physics
Verified
Journal Article
Open access
PDF file
SASamer Afach
Samer Afach
BBBen C. Buchler
Ben C. Buchler
Dmitry BudkerDmitry Budker
Dmitry Budker
CDConner Dailey
Conner Dailey
ADAndrei Derevianko
Andrei Derevianko
JZJianwei Zhang
Jianwei Zhang
Ultralight bosons such as axion-like particles are viable candidates for dark matter. They can form stable, macroscopic field configurations in the form of topological defects that could concentrate the dark matter density into many distinct, compact spatial regions that are small compared with the Galaxy but much larger than the Earth. Here we report the results of the search for transient signals from the domain walls of axion-like particles by using the global network of optical magnetometers for exotic (GNOME) physics searches. We search the data, consisting of correlated measurements from optical atomic magnetometers located in laboratories all over the world, for patterns of signals propagating through the network consistent with domain walls. The analysis of these data from a continuous month-long operation of GNOME finds no statistically significant signals, thus placing experimental constraints on such dark matter scenarios.

1 December 2018 in Physics of the Dark Universe
Verified
Journal Article
Open access
SAS. Afach
S. Afach
DBD. Budker
D. Budker
GDG. DeCamp
G. DeCamp
VDV. Dumont
V. Dumont
ZGZ.D. Grujić
Z.D. Grujić
DWDavid Wurm
David Wurm

18 April 2022 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
MRM. Rosner
M. Rosner
DBD. Beck
D. Beck
PFP. Fierlinger
P. Fierlinger
HFH. Filter
H. Filter
CKC. Klau
C. Klau
ZSZ. Sun
Z. Sun
We report the design and performance of a nonmagnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 and 600 s. The sensor is based on the nonlinear magneto-optical rotation effect: in a Bell–Bloom configuration, a higher order polarization moment (alignment) of Cs atoms is created with a pump laser beam in an anti-relaxation coated Pyrex cell under vacuum, filled with Cs vapor at room temperature. The polarization plane of light passing through the cell is modulated due the precession of the atoms in an external magnetic field of 2.1 μT, used to optically determine the Larmor precession frequency. Operation is based on a sequence of optical pumping and observation of freely precessing spins at a repetition rate of 8 Hz. This free precession decay readout scheme separates optical pumping and probing and, thus, ensures a systematically highly clean measurement. Due to the residual offset of the sensor of <15 pT together with negligible crosstalk of adjacent sensors, this device is uniquely suitable for a variety of experiments in low-energy particle physics with extreme precision, here as a highly stable and systematically clean reference probe in search for time-reversal symmetry violating electric dipole moments.


Verified
Journal Article
Open access
PDF file
DWDavid Wurm
David Wurm
PEPeter Ewert
Peter Ewert
PFPeter Fierlinger
Peter Fierlinger
RWRonald Wakai
Ronald Wakai
VWVerena Wallner
Verena Wallner
AWAnnette Wacker-Gussmann
Annette Wacker-Gussmann
Introduction: Fetal magnetocardiography (fMCG) is considered the best technique for diagnosis of fetal arrhythmia. It is superior to more widely used methods such as fetal, fetal electrocardiography, and cardiotocography for evaluation of fetal rhythm. The combination of fMCG and fetal echocardiography can provide a more comprehensive evaluation of fetal cardiac rhythm and function than is currently possible. In this study, we demonstrate a practical fMCG system based on optically pumped magnetometers (OPMs). Methods: Seven pregnant women with uncomplicated pregnancies underwent fMCG at 26–36 weeks’ gestation. The recordings were made using an OPM-based fMCG system and a person-sized magnetic shield. The shield is much smaller than a shielded room and provides easy access with a large opening that allows the pregnant woman to lie comfortably in a prone position. Results: The data show no significant loss of quality compared to data acquired in a shielded room. Measurements of standard cardiac time intervals yielded the following results: PR = 104 ± 6 ms, QRS = 52.6 ± 1.5 ms, and QTc = 387 ± 19 ms. These results are compatible with those from prior studies performed using superconducting quantum interference device (SQUID) fMCG systems. Conclusions: To our knowledge, this is the first European fMCG device with OPM technology commissioned for basic research in a pediatric cardiology unit. We demonstrated a patient-friendly, comfortable, and open fMCG system. The data yielded consistent cardiac intervals, measured from time-averaged waveforms, compatible with published SQUID and OPM data. This is an important step toward making the method widely accessible.

1 October 2002 in Key Engineering Materials
Verified
Journal Article
Closed access
PDF file
MEM. Alexandra Esteves
M. Alexandra Esteves
MBM.J. Brites
M.J. Brites
MMM.J. Marcelo-Curto
M.J. Marcelo-Curto
BGBarbara Gigante
Barbara Gigante
Traian ZaharescuTraian Zaharescu
Traian Zaharescu
DWDavid Wurm
David Wurm