Due to the complexity of current variation of the multifrequency and multiload (MFML) wireless power transfer (WPT) system based on hysteresis current (HC) control, resulting in a wide range of switching frequency variation, high frequency, and high switching losses of the inverter. This article proposes a blocking delay switching frequency control strategy. Based on the design of blocking delay module, the time division blocking delay and full-time fixed frequency blocking delay control modes are investigated, which can reduce the inverter switching frequency fluctuation range and fix the inverter switching frequency respectively. First, the structure and working principle of the MFML WPT system based on HC control containing passive compensation network are analyzed. Second, the system switching frequency characteristics are analyzed. Third, for different system switching frequency limitation requirements, time division blocking delay control mode and full-time fixed-frequency blocking delay control mode are proposed. Finally, an experimental platform is built to verify the proposed control strategy, the experimental results show that the system switching frequency of different parameters is reduced to within 200 kHz and 180 kHz in the time division blocking delay control, and the system switching frequency is fixed to 150 kHz and 250 kHz in the full-time fixed-frequency blocking delay control.
21 April 2025 in IEEE Transactions on Power Electronics
Accurate detection of metal objects (MO) and live objects (LO) is essential to ensure the safe operation of wireless electric vehicle chargers. This letter proposes a dual-mode foreign object detection (FOD) system. The system utilizes the time division multiplexing mode to detect foreign objects and the frequency sweeping resonance mode to distinguish between MOs and LOs. First, a bipolar overlapping FOD coil is introduced and the effects of MOs and LOs on the coil impedance are analyzed. Subsequently, details regarding the design, operational principles, and detection criteria of the proposed dual-mode FOD system are provided. Finally, the proposed methods are verified with experimental results. The results indicate that a 30 mm diameter aluminum sheet causes a 0.06 V reduction in sampling voltage and a 20 kHz increase in resonance frequency, while a human finger induces a 0.18 V reduction in sampling voltage and a 180 kHz decrease in resonance frequency. These findings confirm the feasibility and effectiveness of the proposed system and its detection criteria.
In order to realize an online power supply, this article develops an explicit design of induction power extraction technology combined with wireless power transmission (WPT) technology. Unlike the power supply mode of traditional batteries of online monitoring devices of high-voltage transmission lines, this technology solves the short battery life cycle problems. First, the principle of induction power extraction is analyzed. Based on the equivalent circuit of the mutual inductance model, expressions of induction power extraction without and with core saturation are derived, respectively. According to the current transformer (CT) magnetic coupling diagram, the open-circuit voltage of the secondary side of the CT is deduced. Therefore, the CT material and size could be selected. The CT coupling model is used to equivalent the current transformer to the ideal voltage source. Then, the four basic topological spaces of the magnetic coupling resonant WPT system are analyzed and calculated, and the efficiency of the SS topology WPT system is analyzed. Furthermore, aiming at long-distance power transmission, this article described the building of a three-coil WPT system and the analysis of the corresponding transmission efficiency and output power expression. With the aid of Maxwell, the technology proposed is simulated based on a 110 kV high-voltage transmission line with 1.2 m as the transmission distance of the system. Finally, the influence of a coupling coefficient and load resistance on the transmission characteristics of the multicoil system is obtained. Consequently, the simulation results with a system output power of 14.4 W verify the effectiveness of the technology.
7 October 2024 in IEEE Transactions on Power Electronics
Metal object detection (MOD) is an essential auxiliary function for wireless electric vehicle charging (WEVC) systems. However, current systems suffer from poor independence, low detection sensitivity, and failures at single detection frequencies. To this end, this article proposes a dual-frequency metal object detection (DF-MOD) technology based on sinusoidal pulsewidth modulation (SPWM) control for WEVC systems. The article first introduces the system structure and working principle, then establishes an equivalent model of the DF-MOD and analyzes its operational characteristics. Subsequently, the parameters for the main circuit and the filter circuit are designed to further enhance the detection sensitivity and anti-interference capability of the DF-MOD system. Finally, a system experimental platform is constructed to verify the feasibility and superiority of the DF-MOD technology controlled by SPWM in WEVC systems. The results indicate that the system achieves independent operation from the WEVC systems and improves detection sensitivity for 40×40 mm copper plates, aluminum plates, iron plates, and ferrite plates by 7.56%, 5.59%, 5.36%, and 16.82%, respectively, compared to single-frequency detection. Additionally, it achieves blind spot-free detection across the entire area.
The problem of current sharing imbalance in the parallel connection of IGBT multi-modules affects the wide-scale application of parallel IGBT. The current imbalance problem in the dynamic process is mainly caused by the difference in control loop parameters. In parallel IGBT applications, current sharing is a critical concern. Objective differences in IGBT module and driver circuit parameters, as well as incomplete symmetry in the power circuit, lead to inconsistent parasitic parameters, resulting in both static and dynamic current-sharing issues. Static current sharing refers to the uneven distribution of load current under static operating conditions, while dynamic current sharing refers to the imbalance in current distribution among parallel IGBT modules during turn-on and turn-off processes. This is mainly influenced by the synchronization of turn-on and turn-off timings and the consistency of collector current change rates during these processes. The difference in characteristic parameters of IGBT modules is an important factor leading to the difference in control loop parameters, which has a profound impact on the dynamic current-sharing characteristics of IGBT parallel applications. In the case where the device parameters cannot be changed, some drive compensation controls can compensate for the influence of device differences on dynamic current sharing. Accurate identification of the characteristic parameters of the IGBT module is the key to this method. This paper mainly studies a synchronous variable-amplitude drive scheme and studies the influence of parameters such as synthetic gate resistance, gate-emitter capacitance, and on-off gate threshold voltage on the dynamic current-sharing characteristics. The correlation characteristics of the characteristic parameters of the IGBT device body are studied, and the characteristic model of each parameter and the influencing variable is constructed. The parallel working model of PSpice devices is established, and the influence of different characteristic parameters on the current-sharing characteristics is evaluated, and its sensitivity is summarized through simulation analysis. Through the 1700 V/300 A IGBT parallel switch characteristic experiment, the current sharing effectiveness of the synchronous variable amplitude driving method is verified. Finally, the effects of different gate control voltages and different action times on the dynamic current-sharing characteristics are summarized.
8 May 2025 in IEEE Transactions on Power Electronics
Because the multifrequency and multiload (MFML) magnetic coupling wireless power transfer (MCR-WPT) system has many varied parameters, which brings great challenges to the system modeling and control, it is important to realize the identification of system parameters. Aiming at the problems that the existing parameter identification technologies have few identification parameters and large calculation amount, this article proposes a parameter identification method for MFML MCR-WPT system based on hysteresis current (HC) control. By analyzing the impedance characteristics at different frequency, the equation set are established. Without changing the system state and additional structure, the mutual inductances and loads can be identified with lower computation complexity. First, the working mechanism and multiparameter identification principle of MFML MCR-WPT system based on HC control are introduced. Second, the system model is established at different frequency, and the frequency expansibility of proposed technology is demonstrated. Third, the equation set are established and simplified based on system impedance characteristic at different frequency. Then, the result and sensitivity of identification method is discussed. Finally, an experimental platform is set up, and the experimental results show that the proposed method can achieve at least 90% identification accuracy.