High di/dt during the close-open operation process of hybrid dc breaker will cause differential mode interference (DMI) in the energy supply system of the breaker's driver units due to their inductive coupling. The generated DMI may lead to false action of the breaker, which is an important issue that should be carefully considered in design stage. A method to analyze DMI based on time-domain wideband circuit simulations is proposed in this article. First, a time-domain waveform expression of DMI voltage source is derived, and then wideband equivalent circuit models of major components in the energy supply system are established. Furthermore, a standardized design methodology to reduce DMI is suggested. Applying the method to a high-frequency energy supply system of a ±200 kV hybrid dc breaker, simulation results show that the DMI level for two DMI mitigation measures is reduced by about 90% and 80% of the initial value, respectively.
The problem of current sharing imbalance in the parallel connection of IGBT multi-modules affects the wide-scale application of parallel IGBT. The current imbalance problem in the dynamic process is mainly caused by the difference in control loop parameters. In parallel IGBT applications, current sharing is a critical concern. Objective differences in IGBT module and driver circuit parameters, as well as incomplete symmetry in the power circuit, lead to inconsistent parasitic parameters, resulting in both static and dynamic current-sharing issues. Static current sharing refers to the uneven distribution of load current under static operating conditions, while dynamic current sharing refers to the imbalance in current distribution among parallel IGBT modules during turn-on and turn-off processes. This is mainly influenced by the synchronization of turn-on and turn-off timings and the consistency of collector current change rates during these processes. The difference in characteristic parameters of IGBT modules is an important factor leading to the difference in control loop parameters, which has a profound impact on the dynamic current-sharing characteristics of IGBT parallel applications. In the case where the device parameters cannot be changed, some drive compensation controls can compensate for the influence of device differences on dynamic current sharing. Accurate identification of the characteristic parameters of the IGBT module is the key to this method. This paper mainly studies a synchronous variable-amplitude drive scheme and studies the influence of parameters such as synthetic gate resistance, gate-emitter capacitance, and on-off gate threshold voltage on the dynamic current-sharing characteristics. The correlation characteristics of the characteristic parameters of the IGBT device body are studied, and the characteristic model of each parameter and the influencing variable is constructed. The parallel working model of PSpice devices is established, and the influence of different characteristic parameters on the current-sharing characteristics is evaluated, and its sensitivity is summarized through simulation analysis. Through the 1700 V/300 A IGBT parallel switch characteristic experiment, the current sharing effectiveness of the synchronous variable amplitude driving method is verified. Finally, the effects of different gate control voltages and different action times on the dynamic current-sharing characteristics are summarized.
Recent studies show that the phase-amplitude coupling (PAC) may play a functional role in information processing and cognition. The conventional method for PAC analysis is implemented by using Fourier-based filters, which assumes the signal is stationary and linear. However, as biological signals are nonstationary and nonlinear, this method introduces inaccuracy. To solve this problem, a new method based on Hilbert Huang Transform (HHT) is proposed in this paper, and is applied to analyze intracranial signals from two epilepsy patients. By displaying PAC comodulograms (coupling maps) in an Intrinsic Mode Function (IMF) domain instead of a traditional frequency domain, the proposed method is able to reveal regular PAC patterns in different seizure stages during seizure evolvement. Comparisons between the conventional and proposed method show the proposed one can provide not only clear but also regular PAC patterns.
17 November 2025 in IEEE Transactions on Instrumentation and Measurement
Even contact pressure distribution among submodules in a press-pack insulated gate bipolar transistor (PP-IGBT) is an important factor in reliability screening tests before engineering application. However, the current stress-sensitive method for contact pressure measurement is an invasive method where each measurement would change the contact pressure distribution of submodules. It is necessary to study a non-invasive measurement method for contact pressure distribution in PP-IGBT. In this paper, a non-invasive measurement method based on the ultrasonic reflection coefficient is proposed to measure the contact pressure distribution within PP-IGBTs. Firstly, the characteristic of ultrasonic wave propagation at the contact interface of two different materials is analyzed. The influence of designed ultrasonic measuring platform for the contact pressure distribution in PP-IGBTs is explored to verify the new assembly measured part has little effects on the pressure distribution within the device by different clamping force experiment. Secondly, an efficient contact pressure measurement system for PP-IGBTs is designed, and a calibration method of ultrasonic reflection coefficient for contact pressure measurement is proposed. Finally, the accuracy of the proposed ultrasonic measurement method for contact pressure distribution is verified by comparing the measurement results with those of the stress-sensitive film method, which the relative error of contact pressure within PP-IGBTs in three different conditions is less than 10%.
1 January 2026 in IEEE Journal of Emerging and Selected Topics in Power Electronics