Ya-Hui Chan

Ya-Hui Chan


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2023 in Polymers
Verified
Journal Article
Open access
PDF file
WHWen-Hsin Huang
Wen-Hsin Huang
CHChia-Yi Hung
Chia-Yi Hung
PCPao-Chang Chiang
Pao-Chang Chiang
HLHsiang Lee
Hsiang Lee
ILI-Ting Lin
I-Ting Lin
SFSheng-Wei Feng
Sheng-Wei Feng
This study reports a carboxymethyl cellulose (CMC)/polyvinyl alcohol (PVA) composite film that incorporates Calendula officinalis (CO) extract for biomedical applications. The morphological, physical, mechanical, hydrophilic, biological, and antibacterial properties of CMC/PVA composite films with various CO concentrations (0.1%, 1%, 2.5%, 4%, and 5%) are fully investigated using different experiments. The surface morphology and structure of the composite films are significantly affected by higher CO concentrations. X-ray diffraction (XRD) and Fourier transform infrared spectrometry (FTIR) analyses confirm the structural interactions among CMC, PVA, and CO. After CO is incorporated, the tensile strength and elongation upon the breaking of the films decrease significantly. The addition of CO significantly reduces the ultimate tensile strength of the composite films from 42.8 to 13.2 MPa. Furthermore, by increasing the concentration of CO to 0.75%, the contact angle is decreased from 15.8° to 10.9°. The MTT [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide] assay reveals that the CMC/PVA/CO-2.5% and CMC/PVA/CO-4% composite films are non-cytotoxic to human skin fibroblast cells, which is favorable for cell proliferation. Remarkably, 2.5% and 4% CO incorporation significantly improve the inhibition ability of the CMC/PVA composite films against Staphylococcus aureus and Escherichia coli. In summary, CMC/PVA composite films containing 2.5% CO exhibit the functional properties for wound healing and biomedical engineering applications.

22 July 2018 in Polymers
Verified
Journal Article
Open access
PDF file
WLWei-Yi Lai
Wei-Yi Lai
SFSheng-Wei Feng
Sheng-Wei Feng
YCYa-Hui Chan
Ya-Hui Chan
WCWei Jen Chang
Wei Jen Chang
HWHsin-Ta Wang
Hsin-Ta Wang
Haw-Ming HuangHaw-Ming Huang
Haw-Ming Huang
Fe3O4 nanoparticles were loaded into poly-l-lactide (PLLA) with concentrations of 2% and 5%, respectively, using an electrospinning method. In vivo animal experiments were then performed to evaluate the potential of the Fe3O4/PLLA nanofibrous material for bone tissue engineering applications. Bony defects with a diameter of 4 mm were prepared in rabbit tibias. Fe3O4/PLLA nanofibers were grafted into the drilled defects and histological examination and computed tomography (CT) image detection were performed after an eight-week healing period. The histological results showed that the artificial bony defects grafted with Fe3O4/PLLA nanofibers exhibited a visibly higher bone healing activity than those grafted with neat PLLA. In addition, the quantitative results from CT images revealed that the bony defects grafted with 2% and 5% Fe3O4/PLLA nanofibers, respectively, showed 1.9- and 2.3-fold increases in bone volume compared to the control blank sample. Overall, the results suggest that the Fe3O4/PLLA nanofibers fabricated in this study may serve as a useful biomaterial for future bone tissue engineering applications.

Verified
Journal Article
Open access
PDF file
KTKuo-Fang Tseng
Kuo-Fang Tseng
SSShiau-Ting Shiu
Shiau-Ting Shiu
CHChia-Yi Hung
Chia-Yi Hung
YCYa-Hui Chan
Ya-Hui Chan
TCTze-Jian Chee
Tze-Jian Chee
SFSheng-Wei Feng
Sheng-Wei Feng
Many studies have been exploring the use of bone graft materials (BGMs) and mesenchymal stem cells in bone defect reconstruction. However, the regeneration potential of Algipore (highly purified hydroxyapatite) and Biphasic (hydroxyapatite/beta-tricalcium phosphate) BGMs combined with bone marrow–derived mesenchymal stem cells (BMSCs) remains unclear. Therefore, we evaluated their osseointegration capacities in reconstructing peri-implant bone defects. The cellular characteristics of BMSCs and the material properties of Algipore and Biphasic were assessed in vitro. Four experimental groups—Algipore, Biphasic, Algipore+BMSCs, and Biphasic+BMSCs—were designed in a rabbit tibia peri-implant defect model. Implant stability parameters were measured. After 4 and 8 weeks of healing, all samples were evaluated using micro-CT, histological, and histomorphometric analysis. In the energy-dispersive X-ray spectroscopy experiment, the Ca/P ratio was higher for Algipore (1.67) than for Biphasic (1.44). The ISQ values continuously increased, and the PTV values gradually decreased for all groups during the healing period. Both Algipore and Biphasic BGM promoted new bone regeneration. Higher implant stability and bone volume density were observed when Algipore and Biphasic BGMs were combined with BMSCs. Biphasic BGM exhibited a faster degradation rate than Algipore BGM. Notably, after eight weeks of healing, Algipore with BSMCs showed more bone–implant contact than Biphasic alone (p < 0.05). Both Algipore and Biphasic are efficient in reconstructing peri-implant bone defects. In addition, Algipore BGM incorporation with BSMCs displayed the best performance in enhancing implant stability and osseointegration potential.