Andreas Edel

Dr. Andreas Edel

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2022 in PLOS Digital Health
Verified
Journal Article
Open access
PDF file
VDVadim Demichev
Vadim Demichev
PTPinkus Tober-Lau
Pinkus Tober-Lau
TNTatiana Nazarenko
Tatiana Nazarenko
OLOliver Lemke
Oliver Lemke
SASimran Kaur Aulakh
Simran Kaur Aulakh
MRMarkus Ralser
Markus Ralser
Global healthcare systems are challenged by the COVID-19 pandemic. There is a need to optimize allocation of treatment and resources in intensive care, as clinically established risk assessments such as SOFA and APACHE II scores show only limited performance for predicting the survival of severely ill COVID-19 patients. Additional tools are also needed to monitor treatment, including experimental therapies in clinical trials. Comprehensively capturing human physiology, we speculated that proteomics in combination with new data-driven analysis strategies could produce a new generation of prognostic discriminators. We studied two independent cohorts of patients with severe COVID-19 who required intensive care and invasive mechanical ventilation. SOFA score, Charlson comorbidity index, and APACHE II score showed limited performance in predicting the COVID-19 outcome. Instead, the quantification of 321 plasma protein groups at 349 timepoints in 50 critically ill patients receiving invasive mechanical ventilation revealed 14 proteins that showed trajectories different between survivors and non-survivors. A predictor trained on proteomic measurements obtained at the first time point at maximum treatment level (i.e. WHO grade 7), which was weeks before the outcome, achieved accurate classification of survivors (AUROC 0.81). We tested the established predictor on an independent validation cohort (AUROC 1.0). The majority of proteins with high relevance in the prediction model belong to the coagulation system and complement cascade. Our study demonstrates that plasma proteomics can give rise to prognostic predictors substantially outperforming current prognostic markers in intensive care.

9 September 2023 in Infection
Verified
Journal Article
Open access
PDF file
DSDaniel Schwarzkopf
Daniel Schwarzkopf
NRNorman Rose
Norman Rose
CFCarolin Fleischmann-Struzek
Carolin Fleischmann-Struzek
BBBeate Boden
Beate Boden
HDHeike Dorow
Heike Dorow
KRKonrad Reinhart
Konrad Reinhart
Purpose: Timely and accurate data on the epidemiology of sepsis are essential to inform policy decisions and research priorities. We aimed to investigate the validity of inpatient administrative health data (IAHD) for surveillance and quality assurance of sepsis care. Methods: We conducted a retrospective validation study in a disproportional stratified random sample of 10,334 inpatient cases of age ≥ 15 years treated in 2015–2017 in ten German hospitals. The accuracy of coding of sepsis and risk factors for mortality in IAHD was assessed compared to reference standard diagnoses obtained by a chart review. Hospital-level risk-adjusted mortality of sepsis as calculated from IAHD information was compared to mortality calculated from chart review information. Results: ICD-coding of sepsis in IAHD showed high positive predictive value (76.9–85.7% depending on sepsis definition), but low sensitivity (26.8–38%), which led to an underestimation of sepsis incidence (1.4% vs. 3.3% for severe sepsis-1). Not naming sepsis in the chart was strongly associated with under-coding of sepsis. The frequency of correctly naming sepsis and ICD-coding of sepsis varied strongly between hospitals (range of sensitivity of naming: 29–71.7%, of ICD-diagnosis: 10.7–58.5%). Risk-adjusted mortality of sepsis per hospital calculated from coding in IAHD showed no substantial correlation to reference standard risk-adjusted mortality (r = 0.09). Conclusion: Due to the under-coding of sepsis in IAHD, previous epidemiological studies underestimated the burden of sepsis in Germany. There is a large variability between hospitals in accuracy of diagnosing and coding of sepsis. Therefore, IAHD alone is not suited to assess quality of sepsis care.

27 January 2025 in Chest
Verified
Journal Article
Open access
NPNicolas Paul
Nicolas Paul
EBElena Ribet Buse
Elena Ribet Buse
JGJulius Grunow
Julius Grunow
SSStefan J Schaller
Stefan J Schaller
CSClaudia D. Spies
Claudia D. Spies
BWBjörn Weiss
Björn Weiss
There is limited knowledge about long-term mortality, care pathways and health-related quality of life (HrQoL) among intensive care unit (ICU) patients receiving prolonged mechanical ventilation (PMV). What are the long-term mortality, care pathways, and HrQoL of patients receiving invasive PMV, stratified by weaning success? and methods: We conducted a secondary analysis of patients from the cluster-randomised controlled Enhanced Recovery after Intensive Care trial who were treated in two ICU clusters and received invasive PMV (≥21 days via endotracheal tube/tracheostomy or ≥four days via tracheostomy). Data on weaning success, mortality, care place transitions, readmissions, and HrQoL were collected for six months after ICU discharge. Of 90 patients receiving PMV in the ICU, 46% (41/90 patients) died (21 patients in the ICU and 20 patients within six months after ICU discharge). Of 69 patients discharged alive, 25% (17/69 patients) could not be weaned, whereas 75% (52/69 patients) were successfully weaned within six months. Patients experienced a median of 3 [Q1, Q3: 2, 5] care place transitions within six months, with more care place transitions among successfully weaned patients (median 4 [Q1, Q3: 2, 5] vs 2 [1, 3], p=0.004). The readmission rate among all patients was 46% after six months. Half of the successfully weaned patients transitioned home, whereas unsuccessfully weaned patients mostly transitioned from weaning centres to nursing homes or died. Unsuccessfully weaned patients had fewer quality-adjusted life days within six months than successfully weaned patients (median 0 [Q1, Q3: 0, 32.6] vs 73.1 [23.2, 135], p=0.002). Three quarters of patients receiving PMV who were discharged alive were weaned, but their HrQoL was reduced. The decision to proceed with PMV should weigh in patient preferences for living with HrQoL limitations and patients' likelihood of weaning. ClinicalTrials.gov (identifier: NCT03671447) on September 12, 2018.

23 February 2026 in Nutrition in Clinical Practice
Verified
Journal Article
Closed access
Arved WeimannArved Weimann
Arved Weimann
AEAndreas Edel
Andreas Edel
Lennart A. LueckeLennart A. Luecke
Lennart A. Luecke
CSChristian Stoppe
Christian Stoppe
KKK. Georg Kreymann
K. Georg Kreymann

8 December 2025 in Infection
Verified
Journal Article
Open access
PDF file
DTDaniel Thomas-Rüddel
Daniel Thomas-Rüddel
NRNorman Rose
Norman Rose
CFCarolin Fleischmann-Struzek
Carolin Fleischmann-Struzek
KRKonrad Reinhart
Konrad Reinhart
BBBeate Boden
Beate Boden
DSDaniel Schwarzkopf
Daniel Schwarzkopf
Purpose: Sepsis is a leading cause of morbidity and mortality, yet its documentation and coding in administrative health data remain unreliable. Accurate coding is essential for epidemiological surveillance, quality assurance, and reimbursement. This study aims to identify patient characteristics associated with under-diagnosis and under-coding of sepsis in German inpatient administrative health data (IAHD). Methods: This secondary analysis of the multicenter OPTIMISE study included 10,334 hospital cases from ten German hospitals (2015–2017). Sepsis cases were identified via structured chart review and compared to ICD-coded diagnoses. Logistic regression and classification tree analyses were used to determine predictors of under-diagnosis and under-coding, including ICU admission, organ dysfunction, and infection source. Results: Among 1,310 cases fulfilling severe sepsis-1 criteria, only 30.7% were correctly coded. The strongest predictor for coding accuracy was explicit mention of sepsis in the medical chart (OR 19.58). ICU treatment, organ dysfunction severity, and mechanical ventilation were also associated with higher coding rates, while pneumonia as the infection source was linked to a lower probability of sepsis being named and coded. Conclusion: Sepsis coding in administrative data is frequently inaccurate. Explicit naming of sepsis and severity markers strongly influence correct coding. As Germany introduces mandatory sepsis quality assurance in 2026, targeted interventions – including enhanced clinician documentation and electronic coding support – are essential to improve coding reliability and patient care.

4 March 2026 in medRxiv
Verified
Preprint
Open access
PDF file
FMFalk Meyer-Eschenbach
Falk Meyer-Eschenbach
RSRené Schmiedler
René Schmiedler
JSJohannes V. Stoephasius
Johannes V. Stoephasius
CZCamille Zhang
Camille Zhang
LKLuis Kronfli
Luis Kronfli
FBFelix Balzer
Felix Balzer
Objective: To systematically review and characterize methodological heterogeneity in sepsis case detection using the MIMIC-III and eICU-CRD databases. Materials and Methods: We conducted a PRISMA-guided systematic review of PubMed and Web of Science (publication years 2016–2024). We extracted methodological details on sepsis case detection across six domains: parameter coverage, temporal windows, aggregation methods, missing-data handling, SOFA calculation, and infection detection methods. For studies with available source code, we additionally examined code structure and repository dependencies to identify methodological decisions across these domains. Results: Of 396 publications screened, 64 met the inclusion criteria and 12 provided available source code. Sepsis detection rates ranged from 3.4% to 65.2% in MIMIC-III and from 9.8% to 47.9% in eICU-CRD. Substantial variability persisted among studies using identical cohort definitions within both databases (MIMIC-III: 16.9%–42.2%; eICU-CRD: 13.9%–31.4%). The overall proportion of studies reporting methodological details varied by domain: SOFA calculation (53.1%), infection detection methods (42.2%), temporal windows (37.5%), aggregation methods (26.6%) and missing-data handling (17.2%). Source code analysis identified 321 implementation decisions, revealing heterogeneity in baseline SOFA definitions (SOFA=0 vs dynamic baseline), temporal windows (infection-centered vs ICU-admission-centered) and infection detection methods (antibiotic-culture matching vs APACHE-based diagnosis). Dependencies among several MIMIC-III repositories suggested propagation of implementation decisions across studies. Discussion: Clinically validated sepsis definitions yield substantially different detection rates across studies using identical datasets, indicating heterogeneity in computational implementation. Conclusion: To improve reproducibility in sepsis research and the robustness of sepsis prediction models, we recommend standardized reporting of sepsis case detection methodology and the publication of version-controlled source code.