Bibi Martens

Bibi Martens


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2020 in Investigative Radiology
Verified
Journal Article
Closed access
BMBibi Martens
Bibi Martens
BHBabs M.F. Hendriks
Babs M.F. Hendriks
CMCasper Mihl
Casper Mihl
JWJoachim E. Wildberger
Joachim E. Wildberger
The latest technical developments in CT have created the possibility for individualized scan protocols at variable kV settings. Lowering tube voltages closer to the K-edge of iodine increases attenuation. However, the latter is also influenced by patient characteristics such as total body weight. To maintain a robust contrast enhancement throughout the patient population in both vascular and parenchymal CT scans, one must adapt the contrast media administration protocols to both the selected kV setting and patient body habitus. This article proposes a simple rule of thumb for how to adapt the contrast media protocol to any kV setting: the 10-to-10 rule.

15 May 2024 in Investigative Radiology
Verified
Journal Article
Open access
MMMichael C. BSc McDermott
Michael C. BSc McDermott
TSThomas Sartoretti
Thomas Sartoretti
LSLion Msc Stammen
Lion Msc Stammen
BMBibi Martens
Bibi Martens
GJGregor Jošt
Gregor Jošt
JWJoachim E. Wildberger
Joachim E. Wildberger
Objective: Photon-counting detector computed tomography (PCD-CT) enables spectral data acquisition of CT angiographies allowing for reconstruction of virtual monoenergetic images (VMIs) in routine practice. Specifically, it has potential to reduce the blooming artifacts associated with densely calcified plaques. However, calcium blooming and iodine attenuation are inversely affected by energy level (keV) of the VMIs, creating a challenge for contrast media (CM) injection protocol optimization. A pragmatic and simple rule for calcium-dependent CM injection protocols is investigated and proposed for VMI-based coronary CT angiography with PCD-CT. Materials and Methods: A physiological circulation phantom with coronary vessels including calcified lesions (maximum CT value >700 HU) with a 50% diameter stenosis was injected into at iodine delivery rates (IDRs) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g I/s. Images were acquired using a first-generation dual-source PCD-CT and reconstructed at various VMI levels (between 45 and 190 keV). Iodine attenuation in the coronaries was measured at each IDR for each keV, and blooming artifacts from the calcified lesions were assessed including stenosis grading error (as % overestimation vs true lumen). The IDR to achieve 300 HU at each VMI level was then calculated and compared with stenosis grading accuracy to establish a general rule for CM injection protocols. Results: Plaque blooming artifacts and intraluminal iodine attenuation decreased with increasing keV. Fixed windowing (representing absolute worst case) resulted in stenosis overestimation from 77% ± 4% at 45 keV to 5% ± 2% at 190 keV, whereas optimized windowing resulted in overestimation from 29% ± 3% at 45 keV to 4% ± 1% at 190 keV. The required IDR to achieve 300 HU showed a strong linear correlation to VMI energy (R 2 = 0.98). Comparison of this linear plot versus stenosis grading error and blooming artifact demonstrated that multipliers of 1, 2, and 3 times the reference IDR for theoretical clinical regimes of no, moderate, and severe calcification density, respectively, can be proposed as a general rule. Conclusions: This study provides a proof-of-concept in an anthropomorphic phantom for a simple pragmatic adaptation of CM injection protocols in coronary CT angiography with PCD-CT. The 1-2-3 rule demonstrates the potential for reducing the effects of calcium blooming artifacts on overall image quality.

25 March 2024 in Investigative Radiology
Verified
Journal Article
Open access
TSThomas Sartoretti
Thomas Sartoretti
MMMichael C. McDermott
Michael C. McDermott
LSLion Stammen
Lion Stammen
BMBibi Martens
Bibi Martens
LMLukas J. Moser
Lukas J. Moser
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
Objectives: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels. Materials and Methods: A cardiovascular phantom exhibiting coronaries with calcified plaques was imaged on a first-generation dual-source PCD-CT. The coronaries with 3 different calcified plaques were filled with iodine and tungsten contrast media solutions equating to iodine and tungsten delivery rates (IDR and TDR) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g/s, respectively. Electrocardiogram-triggered sequential acquisitions were performed in the spectral mode (QuantumPlus). Virtual monoenergetic images (VMIs) were reconstructed from 40 to 190 keV in 1 keV increments. Blooming artifacts and percentage error stenoses from calcified plaques were quantified, and attenuation characteristics of both contrast media were recorded. Results: Blooming artifacts from calcified plaques were most pronounced at 40 keV (78%) and least pronounced at 190 keV (58%). Similarly, percentage error stenoses were highest at 40 keV (48%) and lowest at 190 keV (2%), respectively. Attenuation of iodine decreased monotonically in VMIs from low to high keV, with the strongest decrease from 40 keV to 100 keV (IDR of 2.5 g/s: 1279 HU at 40 keV, 187 HU at 100 kV, and 35 HU at 190 keV). The attenuation of tungsten, on the other hand, increased monotonically as a function of VMI energy, with the strongest increase between 40 and 100 keV (TDR of 2.5 g/s: 202 HU at 40 keV, 661 HU at 100 kV, and 717 HU at 190 keV). For each keV level, the relationship between attenuation and IDR/TDR could be described by linear regressions (R 2 ≥ 0.88, P < 0.001). Specifically, attenuation increased linearly when increasing the delivery rate irrespective of keV level or contrast medium. Iodine exhibited the highest relative increase in attenuation values at lower keV levels when increasing the IDR. Conversely, for tungsten, the greatest relative increase in attenuation values occurred at higher keV levels when increasing the TDR. When high keV imaging is desirable to reduce blooming artifacts from calcified plaques, IDR has to be increased at higher keV levels to maintain diagnostic vessel attenuation (ie, 300 HU), whereas for tungsten, TDR can be kept constant or can be even reduced at high keV energy levels. Conclusions: Tungsten's attenuation characteristics in relation to VMI energy levels are reversed to those of iodine, with tungsten exhibiting high attenuation values at high keV levels and vice versa. Thus, tungsten shows promise for high keV imaging CCTA with PCD-CT as—in distinction to iodine—both high vessel attenuation and low blooming artifacts from calcified plaques can be achieved.

21 December 2021 in Investigative Radiology
Verified
Journal Article
Open access
BMBibi Martens
Bibi Martens
GJGregor Jošt
Gregor Jošt
CMCasper Mihl
Casper Mihl
ENEstelle C. Nijssen
Estelle C. Nijssen
JWJoachim E. Wildberger
Joachim E. Wildberger
HPHubertus Pietsch
Hubertus Pietsch
Background: In contrast-enhanced abdominal computed tomography (CT), radiation and contrast media (CM) injection protocols are closely linked to each other, and therefore a combination is the basis for achieving optimal image quality. However, most studies focus on optimizing one or the other parameter separately. Purpose: Reducing radiation dose may be most important for a young patient or a population in need of repetitive scanning, whereas CM reduction might be key in a population with insufficient renal function. The recently introduced technical solution, in the form of an automated tube voltage selection (ATVS) slider, might be helpful in this respect. The aim of the current study was to systematically evaluate feasibility of optimizing either radiation or CM dose in abdominal imaging compared with a combined approach. Methods: Six Göttingen minipigs (mean weight, 38.9 ± 4.8 kg) were scanned on a third-generation dual-source CT. Automated tube voltage selection and automated tube current modulation techniques were used, with quality reference values of 120 kVref and 210 mAsref. Automated tube voltage selection was set at 90 kV semimode. Three different abdominal scan and CM protocols were compared intraindividually: (1) the standard “combined” protocol, with the ATVS slider position set at 7 and a body weight–adapted CM injection protocol of 350 mg I/kg body weight, iodine delivery rate (IDR) of 1.1 g I/s; (2) the CM dose-saving protocol, with the ATVS slider set at 3 and CM dose lowered to 294 mg I/kg, resulting in a lower IDR of 0.9 g I/s; (3) the radiation dose-saving protocol, with the ATVS slider position set at 11 and a CM dose of 441 mg I/kg and an IDR 1.3 g I/s, respectively. Scans were performed with each protocol in arterial, portal venous, and delayed phase. Objective image quality was evaluated by measuring the attenuation in Hounsfield units, signal-to-noise ratio, and contrast-to-noise ratio of the liver parenchyma. The overall image quality, contrast quality, noise, and lesion detection capability were rated on a 5-point Likert scale (1 = excellent, 5 = very poor). Protocols were compared for objective image quality parameters using 1-way analysis of variance and for subjective image quality parameters using Friedman test. Results: The mean radiation doses were 5.2 ± 1.7 mGy for the standard protocol, 7.1 ± 2.0 mGy for the CM dose-saving protocol, and 3.8 ± 0.4 mGy for the radiation dose-saving protocol. The mean total iodine load in these groups was 13.7 ± 1.7, 11.4 ± 1.4, and 17.2 ± 2.1 g, respectively. No significant differences in subjective overall image or contrast quality were found. Signal-to-noise ratio and contrast-to-noise ratio were not significantly different between protocols in any scan phase. Significantly more noise was seen when using the radiation dose-saving protocol (P < 0.01). In portal venous and delayed phases, the mean attenuation of the liver parenchyma significantly differed between protocols (P < 0.001). Lesion detection was significantly better in portal venous phase using the CM dose-saving protocol compared with the radiation dose-saving protocol (P = 0.037). Conclusions: In this experimental setup, optimizing either radiation (−26%) or CM dose (−16%) is feasible in abdominal CT imaging. Individualizing either radiation or CM dose leads to comparable objective and subjective image quality. Personalized abdominal CT examination protocols can thus be tailored to individual risk assessment and might offer additional degrees of freedom.

5 August 2020 in Investigative Radiology
Verified
Journal Article
Closed access
BMBibi Martens
Bibi Martens
JWJoachim E. Wildberger
Joachim E. Wildberger
BHBabs M.F. Hendriks
Babs M.F. Hendriks
SKSander M.J. Van Kuijk
Sander M.J. Van Kuijk
ENEstelle C. Nijssen
Estelle C. Nijssen
CMCasper Mihl
Casper Mihl
Objectives: The aim of the study was to reach homogeneous enhancement of the liver, irrespective of total body weight (TBW) or tube voltage. An easy-to-use rule of thumb, the 10-to-10 rule, which pairs a 10 kV reduction in tube voltage with a 10% decrease in contrast media (CM) dose, was evaluated. Materials and Methods: A total of 256 patients scheduled for an abdominal CT in portal venous phase were randomly allocated to 1 of 4 groups. In group 1 (n = 64), a tube voltage of 120 kV and a TBW-adapted CM injection protocol was used: 0.521 g I/kg. In group 2 (n = 63), tube voltage was 90 kV and the TBW-adapted CM dosing factor remained 0.521 g I/kg. In group 3 (n = 63), tube voltage was reduced by 20 kV and CM dosing factor by 20% compared with group 1, in line with the 10-to-10 rule (100 kV; 0.417 g I/kg). In group 4 (n = 66), tube voltage was decreased by 30 kV paired with a 30% decrease in CM dosing factor compared with group 1, in line with the 10-to-10 rule (90 kV; 0.365 g I/kg). Objective image quality was evaluated by measuring attenuation in Hounsfield units (HU), signal-to-noise ratio, and contrast-to-noise ratio in the liver. Overall subjective image quality was assessed by 2 experienced readers by using a 5-point Likert scale. Two-sided P values below 0.05 were considered significant. Results: Mean attenuation values in groups 1, 3, and 4 were comparable (118.2 ± 10.0, 117.6 ± 13.9, 117.3 ± 21.6 HU, respectively), whereas attenuation in group 2 (141.0 ± 18.2 HU) was significantly higher than all other groups (P < 0.01). No significant difference in attenuation was found between weight categories 80 kg or less and greater than 80 kg within the 4 groups (P ≥ 0.371). No significant differences in subjective image quality were found (P = 0.180). Conclusions: The proposed 10-to-10 rule is an easily reproducible method resulting in similar enhancement in portal venous CT of the liver throughout the patient population, irrespective of TBW or tube voltage.

13 April 2022 in Journal of Thoracic Imaging
Verified
Journal Article
Open access
BMBibi Martens
Bibi Martens
RDRob G.H. Driessen
Rob G.H. Driessen
LBLloyd Brandts
Lloyd Brandts
PHPuck Msc Hoitinga
Puck Msc Hoitinga
FVFauve Msc van Veen
Fauve Msc van Veen
CMCasper Mihl
Casper Mihl
Purpose: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is regarded as a multisystemic disease. Patients with preexisting cardiovascular disease have an increased risk for a more severe disease course. This study aimed to investigate if a higher degree of coronary artery calcifications (CAC) on a standard chest computed tomography (CT) scan in mechanically ventilated patients was associated with a more severe multiorgan failure over time. Materials and Methods: All mechanically ventilated intensive care unit patients with SARS-CoV-2 infection who underwent a chest CT were prospectively included. CT was used to establish the extent of CAC using a semiquantitative grading system. We categorized patients into 3 sex-specific tertiles of CAC: lowest, intermediate, and highest CAC score. Daily, the Sequential Organ Failure Assessment (SOFA) scores were collected to evaluate organ failure over time. Linear mixed-effects regression was used to investigate differences in SOFA scores between tertiles. The models were adjusted for age, sex, Acute Physiology and Chronic Health Evaluation II (APACHE II) score, cardiovascular risk factors, and chronic liver, lung, and renal disease. Results: In all, 71 patients were included. Patients in the highest CAC tertile had, on average, over time, 1.8 (0.5-3.1) points higher SOFA score, compared with the lowest CAC tertile (P=0.005). This association remained significant after adjustment for age, sex, and APACHE II score (1.4 [0.1-2.7], P=0.042) and clinically relevant after adjustment for cardiovascular risk factors (1.3 [0.0-2.7], P=0.06) and chronic diseases (1.3 [−0.2 to 2.7], P=0.085). Conclusion: A greater extent of CAC is associated with a more severe multiorgan failure in mechanically ventilated coronavirus disease 2019 patients.