Santosh Lakshmi Gande

Dr. Santosh Lakshmi Gande


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
RTRobert Tannenberg
Robert Tannenberg
MPMartin Paul
Martin Paul
BRBettina Röder
Bettina Röder
SGSantosh Lakshmi Gande
Santosh Lakshmi Gande
SSSridhar Sreeramulu
Sridhar Sreeramulu
Michael G. WellerMichael G. Weller
Michael G. Weller
Cardiac vascular diseases, especially acute myocardial infarction (AMI), are one of the leading causes of death worldwide. Therefore cardio-specific biomarkers such as cardiac troponin I (cTnI) play an essential role in the field of diagnostics. In order to enable rapid and accurate measurement of cTnI with the potential of online measurements, a chemiluminescence-based immunosensor is presented as a proof of concept. A flow cell was designed and combined with a sensitive CMOS camera allowing sensitive optical readout. In addition, a microfluidic setup was established, which achieved selective and quasi-online cTnI determination within ten minutes. The sensor was tested with recombinant cTnI in phosphate buffer and demonstrated cTnI measurements in the concentration range of 2–25 µg/L. With the optimized system, a limit of detection (LoD) of 0.6 µg/L (23 pmol/L) was achieved. Furthermore, the selectivity of the immunosensor was investigated with other recombinant proteins, such as cTnT, and cTnC, at a level of 16 µg/L. No cross-reactivity could be observed. Measurements with diluted blood plasma and serum resulted in an LoD of 60 µg/L (2.4 nmol/L) and 70 µg/L (2.9 nmol/L), respectively.

10 February 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
RTRobert Tannenberg
Robert Tannenberg
MPMartin Paul
Martin Paul
BRBettina Röder
Bettina Röder
SGSantosh Lakshmi Gande
Santosh Lakshmi Gande
SSSridhar Sreeramulu
Sridhar Sreeramulu
Michael G. WellerMichael G. Weller
Michael G. Weller
Cardiac vascular diseases, especially acute myocardial infarction (AMI), are one of the leading causes of death worldwide. Therefore cardio-specific biomarkers such as cardiac Troponin I (cTnI) play an essential role in diagnostics. In order to enable rapid and accurate measurement of cTnI with the potential of online measurements, a proof of concept of a chemiluminescence-based biosensor is presented. A flow cell was designed and combined with a sensitive CMOS camera allowing an optical readout. In addition, a microfluidic setup was established, and cTnI was determined selectively. The biomarker cTnI was expressed in E. coli, and its characterization and correct folding were investigated by different analytical methods. This recombinant cTnI was used for enzyme-linked immunosorbent assays (ELISA), calibrated against commercially available recombinant cTnI, and applied for the biosensor measurements. Based on chemiluminescence detection, the biosensor was successfully tested, and the cTnI biomarker could be reproducibly determined in buffer, spiked blood serum, and plasma.