Robert Tannenberg

Mr. Robert Tannenberg


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
RTRobert Tannenberg
Robert Tannenberg
MPMartin Paul
Martin Paul
BRBettina Röder
Bettina Röder
SGSantosh Lakshmi Gande
Santosh Lakshmi Gande
SSSridhar Sreeramulu
Sridhar Sreeramulu
Michael G. WellerMichael G. Weller
Michael G. Weller
Cardiac vascular diseases, especially acute myocardial infarction (AMI), are one of the leading causes of death worldwide. Therefore cardio-specific biomarkers such as cardiac troponin I (cTnI) play an essential role in the field of diagnostics. In order to enable rapid and accurate measurement of cTnI with the potential of online measurements, a chemiluminescence-based immunosensor is presented as a proof of concept. A flow cell was designed and combined with a sensitive CMOS camera allowing sensitive optical readout. In addition, a microfluidic setup was established, which achieved selective and quasi-online cTnI determination within ten minutes. The sensor was tested with recombinant cTnI in phosphate buffer and demonstrated cTnI measurements in the concentration range of 2–25 µg/L. With the optimized system, a limit of detection (LoD) of 0.6 µg/L (23 pmol/L) was achieved. Furthermore, the selectivity of the immunosensor was investigated with other recombinant proteins, such as cTnT, and cTnC, at a level of 16 µg/L. No cross-reactivity could be observed. Measurements with diluted blood plasma and serum resulted in an LoD of 60 µg/L (2.4 nmol/L) and 70 µg/L (2.9 nmol/L), respectively.

3 September 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
MPMartin Paul
Martin Paul
RTRobert Tannenberg
Robert Tannenberg
GTGeorg Tscheuschner
Georg Tscheuschner
MPMarco Ponader
Marco Ponader
Michael G. WellerMichael G. Weller
Michael G. Weller
The trafficking of illegal drugs by criminal networks at borders, harbors, or airports is an increasing issue for public health as these routes ensure the main supply of illegal drugs. The prevention of drug smuggling, including the installation of scanners and other analytical devices to detect small traces of drugs within a reasonable time frame, remains a challenge. The presented immunosensor is based on a monolithic affinity column with a large excess of immobilized hapten, which traps fluorescently labeled antibodies as long as the analyte cocaine is absent. In the presence of the drug, some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and microfluidic chip-based mixing devices and flow cells. The biosensor achieved limits of detection of 7 ppt (23 pM) of cocaine with a response time of 90 s and a total assay time below 3 min. With surface wipe sampling, the biosensor was able to detect 300 pg of cocaine. This immunosensor belongs to the most sensitive and fastest detectors for cocaine and offers near-continuous analyte measurement.

10 February 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
RTRobert Tannenberg
Robert Tannenberg
MPMartin Paul
Martin Paul
BRBettina Röder
Bettina Röder
SGSantosh Lakshmi Gande
Santosh Lakshmi Gande
SSSridhar Sreeramulu
Sridhar Sreeramulu
Michael G. WellerMichael G. Weller
Michael G. Weller
Cardiac vascular diseases, especially acute myocardial infarction (AMI), are one of the leading causes of death worldwide. Therefore cardio-specific biomarkers such as cardiac Troponin I (cTnI) play an essential role in diagnostics. In order to enable rapid and accurate measurement of cTnI with the potential of online measurements, a proof of concept of a chemiluminescence-based biosensor is presented. A flow cell was designed and combined with a sensitive CMOS camera allowing an optical readout. In addition, a microfluidic setup was established, and cTnI was determined selectively. The biomarker cTnI was expressed in E. coli, and its characterization and correct folding were investigated by different analytical methods. This recombinant cTnI was used for enzyme-linked immunosorbent assays (ELISA), calibrated against commercially available recombinant cTnI, and applied for the biosensor measurements. Based on chemiluminescence detection, the biosensor was successfully tested, and the cTnI biomarker could be reproducibly determined in buffer, spiked blood serum, and plasma.

4 February 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
RTRobert Tannenberg
Robert Tannenberg
GTGeorg Tscheuschner
Georg Tscheuschner
CRChristopher Raab
Christopher Raab
SFSabine Flemig
Sabine Flemig
SDSarah Döring
Sarah Döring
Michael G. WellerMichael G. Weller
Michael G. Weller
Lateral flow immunoassays (LFAs) are widely used for on-site testing; however, their use for the rapid detection of plant viruses in the field is often limited by inconvenient sample preparation. Here, we present a new sampling method and a simplified dipstick LFA format for the detection and monitoring of cowpea chlorotic mottle virus (CCMV) as a model plant pathogen. The assay employs a monoclonal mouse antibody for capture and a poly-clonal rabbit antibody conjugated to 80 nm gold nanoparticles for detection. Conventional sample and conjugate pads are omitted, allowing the test strips to be dipped directly into wells containing plant extract and antibody–gold conjugate. No plastic casing was required, which could lead to a reduction in waste. It was shown that CCMV concentrations as low as 3.5 µg/L or 350 pg per sample could be reliably detected in 15 min. Specificity tests confirmed that other plant viruses, cowpea mosaic virus (CPMV) and tobacco mosaic virus (TMV), did not produce false-positive results. In addition, we describe a new method for on-site sampling using a manual punch and a syringe equipped with a frit. This step combines grinding the sample, extraction, filtration, and reconstitution and mixing of the antibody-gold conjugate, enabling the analysis of punched leaf disks without laboratory equipment. When applied to CCMV-infected cowpea plants, the assay revealed systemic infection before visual symptoms became apparent. This work demonstrates that simplified LFAs combined with innovative sampling techniques can provide sensitive, specific, and rapid diagnostics for crop monitoring and support early intervention strategies in agriculture.

17 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
RTRobert Tannenberg
Robert Tannenberg
GTGeorg Tscheuschner
Georg Tscheuschner
CRChristopher Raab
Christopher Raab
SFSabine Flemig
Sabine Flemig
SDSarah Döring
Sarah Döring
Michael G. WellerMichael G. Weller
Michael G. Weller
Lateral flow immunoassays (LFA) are widely used for decentralized testing, but their application for in-field plant virus diagnostics is often limited by tedious sample preparation. Here, we present a simplified dipstick LFA for the detection and monitoring of cowpea chlorotic mottle virus (CCMV) as a model plant pathogen. The assay employes a monoclonal mouse antibody for capture and a polyclonal rabbit antibody conjugated to 80-nm gold nanoparticles for detection. Conventional sample and conjugate pads are omitted, allowing the test strips to be dipped directly into wells containing plant extract and antibody-gold conjugate. In addition, no plastic casing was necessary, which significantly reduces waste. It was shown that CCMV concentrations as low as 4 µg/L or 400 pg per sample could be reliably detected in 15 minutes. Specificity tests confirmed that other plant viruses, cowpea mosaic virus (CPMV) and tobacco mosaic virus (TMV), did not produce false positive results. Furthermore, we describe a field-compatible sampling procedure using a manual punch and a disposable syringe. This step combines sample grinding, extraction, and conjugate reconstitution within the syringe frit, enabling the analysis of punched leaf discs without laboratory equipment. When applied to CCMV-infected cowpea plants, the assay revealed systemic infection before visual symptoms became apparent. This work demonstrates that simplified LFAs combined with innovative sampling techniques can provide sensitive, specific, and rapid diagnostics for crop monitoring and support early intervention strategies in agriculture.