Voluntary runners are subjected to a massive increase in reactive oxygen/nitrogen species production, which can promote different oxidative stress-related diseases such as premature aging, neurodegenerative disorders, and cancer. The aims of this work were to evaluate the following in peripheral blood cells of voluntary runners: (i) DNA status; (ii) susceptibility to the in vitro insult induced by hydrogen peroxide (H(2)O(2)) as a breaking agent; (iii) capabilities of 3,5,4'-trihydroxystilbene (RESV) in counteracting DNA damage. Twenty-five male voluntary runners were compared with 20 sedentary men, as age-matched controls, and DNA status was evaluated with different versions of comet assay: alkaline, neutral, and Fpg enzyme-modified version to measure 8-OH-deoxyguanosine (8-oxo-dG) levels. The H(2)O(2) and/or RESV treatments were performed directly on agarose-embedded cells (atypical comet assay). The results evidenced DNA damage and levels of 8-oxo-dG higher in runners than in sedentary control subjects. The runners' DNA was more prone to the in vitro-induced oxidative insult (200 μM H(2)O(2)) than that of the control group. Resveratrol (100 μM), depending on the individual basal DNA status, was able to switch from antioxidant to pro-oxidant. Our results, on the one hand, validated the proposed in vitro experimental protocol in order to measure individual DNA status. On the other hand, our data point out the importance of monitoring the athletes' redox status before subjecting them to dietary supplementation treatment.
1 December 2015 in Sensing and Bio-Sensing Research
In this work, we simulated and experimentally assessed the possibility to detect, through electrical transduction, hybridization of DNA molecules on MOS-like devices, having different dielectrics: SiO2, Si3N4 and SiO2/Si3N4/SiO2 (ONO). The electrical characterization was performed after the various functionalization steps, consisting of dielectric activation, silanization, DNA spotting and anchoring, and after the hybridization process, to test the devices effectiveness as DNA recognition biosensors. The experimental results were used to validate device simulations. The comparison shows the ability to determine a priori the DNA probe density needed to maximize the response. The results confirm that the structures analyzed are sensitive to the immobilization of DNA and its hybridization
We demonstrate a method to characterize the beam energy, transverse profile, charge, and dose of a pulsed electron beam generated by a 1 kHz TW laser-plasma accelerator. The method is based on imaging with a scintillating screen in an inhomogeneous, orthogonal magnetic field produced by a wide-gap magnetic dipole. Numerical simulations were developed to reconstruct the electron beam parameters accurately. The method has been experimentally verified and calibrated using a medical LINAC. The energy measurement accuracy in the 6–20 MeV range is proven to be better than 10%. The radiation dose has been calibrated by a water-equivalent phantom, RW3, showing a linear response of the method within 2% in the 0.05–0.5 mGy/pulse range.