In order to fully benefit from the functionalities of flexible endoscopes in surgery a simple shaft-guide that can be used to support the flexible endoscope shaft is required. Such a shaft-guide must be flexible during insertion into the human body and rigidified when properly positioned to support the flexible endoscope shaft. A shaft-guide called ‘Vacu-SL’ was designed, consisting of a foil tube, filled with particles, that is rigidified by creating a vacuum in its tube. It is expected that the bending stiffness of a loaded, rigidified Vacu-SL shaft-guide is significantly influenced by the shape, hardness and size of the filler particles used. The goal of this study was to find the relations between the filler particles’ size, shape and hardness and a rigidified Vacu-SL shaft-guide’s bending stiffness. Vacu-SL test models were made using polystyrene, acrylic glass, glass, steel, and corundum particles as spheres, pebbles and granulate, with average diameters between 0.16–1.7 mm. These test models were rigidified and then loaded in a tensile tester. The forces needed for 5 and 10 mm deflections of the rigidified test models were measured. The results show that particle size, shape and hardness all influence a rigidified Vacu-SL shaft-guide’s bending stiffness. Size and hardness showed an optimum and granules performed better than spheres. Although the maximally measured bending stiffness might be insufficient to enable proper guidance of flexible endoscope shafts, the results suggest several ways to successfully improve the Vacu-SL shaft-guide.
1 February 2012 in IEEE Transactions on Biomedical Engineering
Recent developments in flexible endoscopy and other fields of medical technology have raised the need for compact slender shafts that can be made rigid and compliant at will. A novel compact mechanism, named FORGUIDE, with this functionality was developed. The FORGUIDE shaft rigidifies due to friction between a ring of cables situated between a spring and an inflated tube. A mathematical model for the FORGUIDE mechanism working principle was made and used to obtain understanding of this mechanism, predict the maximum rigidity of a FORGUIDE shaft design, and tune its design variables. The mathematical model gave suggestions for significant performance improvement by fine-tuning the design. A prototype FORGUIDE shaft was built and put to a series of bench tests. These tests showed that the FORGUIDE mechanism provides a reliable and simple way to control the rigidity of a flexible shaft.
When sawing during autopsies on human remains, fine dust is produced, which consists of particles of sizes that may fall within the human respirable range, and can act as vectors for pathogens. The goal of this study was to explore the potential effects of saw blade frequency and saw blade contact load on the number and size of airborne bone particles produced. The methodology involved the use of an oscillating saw with variable saw blade frequencies and different saw blade contact loads on dry human femora. Released airborne particles were counted per diameter by a particle counter inside a closed and controlled environment. Results corroborated with the hypotheses: higher frequencies or lower contact loads resulted in higher numbers of aerosol particles produced. However, it was found that even in the best-case scenario tested on dry bone, the number of aerosol particles produced was still high enough to provide a potential health risk to the forensic practitioners. Protective breathing gear such as respirators and biosafety protocols are recommended to be put into practice to protect forensic practitioners from acquiring pathologies, or from other biological hazards when performing autopsies.
1 January 2013 in Canadian Journal of Gastroenterology and Hepatology
BACKGROUND: Colonoscopy requires highly skill-dependent manoeuvres that demand a significant amount of training, and can cause considerable discomfort to patients, which increases the use of sedatives. Understanding the underlying fundamental mechanics behind insertion difficulties and pain during colonoscopy may help to simplify colonoscopy and reduce the required extent of training and reliance on sedatives.METHODS: A literature search, anatomical studies, models of the colon and colonoscope, and bench tests were used to qualitatively analyze the fundamental mechanical causes of insertion difficulties and pain. A categorized review resulted in an overview of potential alternatives to current colonoscopes.RESULTS: To advance a colonoscope through the colon, the colon wall, ligaments and peritoneum must be stretched, thus creating tension in the colon wall, which resists further wall deformation. This resistance forces the colonoscope to bend and follow the curves of the colon. The deformations that cause insertion difficulties and pain (necessitating the use of complex conventional manoeuvres) are the stretching of ligaments, and stretching of colon wall in the transverse and longitudinal directions, and the peritoneum.CONCLUSIONS: Four fundamental mechanical solutions to prevent these deformations were extracted from the analysis. The current results may help in the development of new colonoscopy devices that reduce – or eliminate – the necessity of using highly skill-dependent manoeuvres, facilitate training and reduce the use of sedatives.
11 February 2022 in International Journal of Oral and Maxillofacial Surgery
Flexible endoscopes are used for diagnostic and therapeutic interventions in the human body for their ability to be advanced through tortuous trajectories. However, this very same property causes difficulties as well. For example, during surgery, a rigid shaft would be more beneficial since it provides more stability and it allows for better surgical accuracy. In order to keep the flexibility and to obtain the rigidity when needed, a shaft-guide with controllable rigidity could be used. In this article, we introduce the plastolock shaft-guide concept, which uses thermoplastics that are reversibly switched from rigid to compliant by changing their temperatures from to . These materials are used to make a shaft that can be rendered flexible to follow the flexible endoscope and rigid to guide it. To find polymers that are suitable for the plastolock concept, an extensive database and internet search was performed. The results suggest that many suitable materials are available or can be custom synthesized to meet the requirements. The thermoplastic polymer Purasorb® PLC 7015 was obtained and a dynamic mechanical analysis showed that it is suitable for the plastolock concept. A simple production test indicated that this material is suitable for prototyping by molding. Overall, the results in this article show that the plastolock concept can offer simple, scalable solutions for medical situations that desire stiffness at one instance and flexibility at another.