In order to fully benefit from the functionalities of flexible endoscopes in surgery a simple shaft-guide that can be used to support the flexible endoscope shaft is required. Such a shaft-guide must be flexible during insertion into the human body and rigidified when properly positioned to support the flexible endoscope shaft. A shaft-guide called ‘Vacu-SL’ was designed, consisting of a foil tube, filled with particles, that is rigidified by creating a vacuum in its tube. It is expected that the bending stiffness of a loaded, rigidified Vacu-SL shaft-guide is significantly influenced by the shape, hardness and size of the filler particles used. The goal of this study was to find the relations between the filler particles’ size, shape and hardness and a rigidified Vacu-SL shaft-guide’s bending stiffness. Vacu-SL test models were made using polystyrene, acrylic glass, glass, steel, and corundum particles as spheres, pebbles and granulate, with average diameters between 0.16–1.7 mm. These test models were rigidified and then loaded in a tensile tester. The forces needed for 5 and 10 mm deflections of the rigidified test models were measured. The results show that particle size, shape and hardness all influence a rigidified Vacu-SL shaft-guide’s bending stiffness. Size and hardness showed an optimum and granules performed better than spheres. Although the maximally measured bending stiffness might be insufficient to enable proper guidance of flexible endoscope shafts, the results suggest several ways to successfully improve the Vacu-SL shaft-guide.
16 December 2019 in Microsystems & Nanoengineering
Commercially available gravimeters and seismometers can be used for measuring Earth’s acceleration at resolution levels in the order of $${\mathrm{ng}}/\sqrt {\mathrm{Hz}}$$ (where g represents earth’s gravity) but they are typically high-cost and bulky. In this work the design of a bulk micromachined MEMS device exploiting non-linear buckling behaviour is described, aiming for $${\mathrm{ng}}/\sqrt {\mathrm{Hz}}$$ resolution by maximising mechanical and capacitive sensitivity. High mechanical sensitivity is obtained through low structural stiffness. Near-zero stiffness is achieved through geometric design and large deformation into a region where the mechanism is statically balanced or neutrally stable. Moreover, the device has an integrated capacitive comb transducer and makes use of a high-resolution impedance readout ASIC. The sensitivity from displacement to a change in capacitance was maximised within the design and process boundaries given, by making use of a trench isolation technique and exploiting the large-displacement behaviour of the device. The measurement results demonstrate that the resonance frequency can be tuned from 8.7 Hz–18.7 Hz, depending on the process parameters and the tilt of the device. In this system, which combines an integrated capacitive transducer with a sensitivity of 2.55 aF/nm and an impedance readout chip, the theoretically achievable system resolution equals 17.02 $${\mathrm{ng}}/\sqrt {\mathrm{Hz}}$$ . The small size of the device and the use of integrated readout electronics allow for a wide range of practical applications for data collection aimed at the internet of things.
17 May 2018 in IEEE Journal of Solid-State Circuits
This paper presents an eddy-current sensor (ECS) interface intended for sub-nanometer (sub-nm) displacement sensing in hi-tech applications. The interface employs a 126-MHz excitation frequency to mitigate the skin effect, and achieve high resolution and stability. An efficient on-chip sensor offset compensation scheme is introduced which removes sensor-offset proportional to the standoff distance. To assist in the ratiometric suppression of noise and drift of the excitation oscillator, the ECS interface consists of a highly linear amplitude demodulation scheme that employs passive capacitors for voltage-to-current (V2I) conversion. Using a printed circuit board-based pseudo-differential ECS, stability tests were performed which demonstrated a thermal drift of <7.3 nm/°C and long-term drift of only 29.5 nm over a period of 60 h. The interface achieves an effective noise floor of 13.4 pm/√ Hz which corresponds to a displacement resolution of 0.6 nm in a 2-kHz noise bandwidth. The ECS interface is fabricated in TSMC 0.18-μm CMOS technology and dissipates only 19.8 mW from a 1.8-V supply.
This paper presents a comprehensive study of demodulation techniques for high-frequency self-oscillating eddy-current displacement sensor (ECDS) interfaces. Increasing the excitation frequency is essential for lowering the skin depth in many demanding industrial applications, that require better resolution. However, a high excitation frequency poses design challenges in the readout electronics, and particularly in the demodulation functional block. We analyze noise, linearity, and stability design considerations in amplitude demodulators for nanometer and sub-nanometer ECDSs. A number of state-of-the-art amplitude demodulation techniques employed in high-frequency ECDSs are reviewed, and their pros and cons are evaluated.
This paper presents a direct digital converter for Wheatstone bridge sensors which is realized with commercial off-the-shelf (COTS) components. The power efficiency of the readout is enhanced by embedding the bridge sensor in a second-order Continuous-Time Sigma-Delta Modulator (CTΔ∑M). By directly digitizing the output signal of a Wheatstone bridge in the current mode, the noise performance is dominated by the operational amplifier (Opamp) in the first integrator and the bridge sensor. To demonstrate the performance of the proposed circuit, a MEMS Piezoresistive Differential Pressure (MPDP) sensor is used. Measurement results show a resolution of 12.7 mParms (0.41 mΩrms), with a 0.5 ms conversion time, can be achieved. Powered by 5 V, the circuit and the bridge sensor draws 9.55 mW and 7.58 mW, respectively.
15 November 2017 in IEEE Transactions on Instrumentation and Measurement
High-precision positioning often requires high speed and high resolution displacement measurements in order to compensate for the small vibrations of critical components. The displacement sensor must be precise and stable over a long period of time to avoid expensive recalibration. This requires tight mounting tolerances, which are especially difficult to meet in inaccessible environments. The proposed sensor system is based on a capacitive sensor and consists of three subsystems: 1) a mechanical ``zoom-in'' system that performs self-alignment of the capacitive sensor electrode in order to reduce the mounting tolerances of the sensor; 2) a real-time capacitance-to-digital converter that employs an internal reference and electrical zoom-in technique to effectively reduce the dynamic range of the measured capacitance, thus improving the power efficiency; and 3) a self-calibration circuit that periodically calibrates the internal references to eliminate their drift. In previous publications, the three subsystems have been introduced. This paper shows how the different subsystems can be integrated to achieve optimal performance and presents new repeatability and stability measurement results. The overall system demonstrates a displacement measurement resolution of 65 pm (in terms of capacitance 65 aF) for a measurement time of 20 μs. Furthermore, the thermal drift of the sensor is within 6 ppm/K, owing to the self-calibration circuit. In measurement mode, the system consumes less than 16 mW.