An ultrasensitive strain sensor with a wide strain range based on graphene armour scales is demonstrated in this paper. The sensor shows an ultra-high gauge factor (GF, up to 1054) and a wide strain range (ε = 26%), both of which present an advantage compared to most other flexible sensors. Moreover, the sensor is developed by a simple fabrication process. Due to the excellent performance, this strain sensor can meet the demands of subtle, large and complex human motion monitoring, which indicates its tremendous application potential in health monitoring, mechanical control, real-time motion monitoring and so on.
Running speed degradation of insect-scale (less than 5 cm) legged microrobots after carrying payloads has become a bottleneck for microrobots to achieve high untethered locomotion performance. In this work, we present a 2-cm legged microrobot (BHMbot, BeiHang Microrobot) with ultrafast untethered running speeds, which is facilitated by the complementary combination of bouncing length and bouncing frequency in the microrobot’s running gait. The untethered BHMbot (2-cm-long, 1760 mg) can achieve a running speed of 17.5 BL s−1and a turning centripetal acceleration of 65.4 BL s−2at a Cost of Transport of 303.7 and a power consumption of 1.77 W. By controlling its two front legs independently, the BHMbot demonstrates various locomotion trajectories including circles, rectangles, letters and irregular paths across obstacles through a wireless control module. Such advancements enable the BHMbot to carry out application attempts including sound signal detection, locomotion inside a turbofan engine and transportation via a quadrotor.
18 August 2015 in Journal of Micromechanics and Microengineering
In this paper, an electric field sensor (EFS) with high sensitivity is proposed for low-frequency weak-strength ac electric field (E-field) measurements. The EFS is based on a piezoelectric cantilever biased by a strong electrostatic field. The electrostatic bias can enhance the electric field force of a weak ac E-field, thus the cantilever can oscillate in a weak ac E-field and the device sensitivity improves. Theoretical analyses have been established and suggest that a stronger strength of electrostatic field bias would produce a higher sensitivity improvement. In the experiment, a demonstrated sensor consisting of a polyvinylidene fluoride (PVDF) piezoelectric cantilever and a polytetrafluoroethylene (PTFE) electret was built and tested. Instead of extra voltage sources, the PTFE electret was charged to provide the electrostatic field, allowing the EFS a low energy consumption and a simple electric circuit design. The experiment results show good agreement with the simulation. The sensitivity of the cantilever E-field sensor reached 0.84 mV (kV/m)−1 when the surface potential of the electret was −770 V.
16 July 2021 in IEEE Transactions on Electron Devices
The outstanding physical and electrical properties of transition metal dichalcogenides (TMDs) as semiconductor materials demonstrate a promising platform for future electronic devices. Among all the TMDs, MoTe 2 , in which the bandgap is close to that of the silicon (Si), is a more favorable candidate than others to be applied in next-generation integrated circuits (ICs). However, the conventional physical or chemical doping method is complicated for fabricating the MoTe 2 logic ICs. The transistors with additional polarity gates (PGs) are defined as polarity-controllable transistors (PCTs). The PG can dynamically control the type of charge carriers (n- or p-type) in the source/drain by electrostatic doping without the need of any physical or chemical doping, and thus reconfigure the transistor between n-type and p-type. In our work, the ambipolar conduction property in MoTe 2 enables the fabrication of high-quality polarity-controllable MoTe 2 transistors (PCMTs) that are promising as building blocks to construct the MoTe 2 logic ICs. The on/off ratios of the PCMTs are above 10 7 for both n-type and p-type. The highest field-effect mobility μ of p- and n-type MoTe 2 transistors are 38 and 42, respectively. The inverter (INV) based on the PCMTs has achieved a high gain of 37. Furthermore, the logic-gate cell library, which includes INV, negative- AND (NAND), negative- OR (NOR), exclusive- OR (XOR), and maJority (MAJ) is demonstrated using PCMTs. The above-mentioned desirable properties make PCMTs promising for future applications in 2-D-semiconductor-material-based logic ICs.
In clinical, the center of pressure (CoP) is commonly used for accessing the stability of a person’s postural control, which is highly associated with various neurological diseases and movement disorders such as Alzheimer’s disease, Parkinson’s disease, chronic ankle instability. Such a disease usually has a long development or rehabilitation process which requires long-term CoP monitoring. The current CoP evaluation process does not meet the requirement, as it is often complicated and expensive through either the lab-based equipment or the clinical evaluation procedure. Different wearable sensor-based systems with less cost and restrictions have emerged, but their way of CoP calculation requires deliberate calibration of the positions of their sensors, which are not feasible in daily CoP monitoring. In this study, we developed a long-term CoP monitoring system in a smart-shoe form. First, a thin and flexible smart insole with optimal sensor locations was designed to be compact and energy sufficient for a whole-day usage. Then, a user-friendly app on the smartphone with a cloud-based data managing system was developed for applications in both clinical and home environments. Additionally, a simplified CoP estimation model was created without the need for calibration. Lastly, a machine learning-based human activity recognition method was incorporated to make the CoP detection process more automatic. Through a thorough validation test with the clinical level lab equipment, our system can generate the CoP measurements with high accuracy.
1 February 2022 in IEEE Transactions on Electron Devices
In this article, we investigate the role of MoO x oxide electrodes on the ferroelectric properties of hafnium zirconium oxide (HZO) capacitors. The MoO x oxide electrodes were deposited under different oxygen partial pressure ratios ( $\text{O}_{\text {ppr}}$ : 0%, 5%, 10%, and 15%) during the sputtering process. The remnant polarization ( ${P}_{r}$ ) of the HZO capacitors with MoO x electrodes (18.9 $\mu \text{C}$ /cm 2 for 10% $\text{O}_{\text {ppr}}$ ) are improved higher than that of the TiN electrode (14.9 $\mu \text{C}$ /cm 2 ) by 27%. In addition, the HZO films with MoO x electrodes have smaller leakage current and larger breakdown electric field ( ${E}_{\text {BD}}$ ). Based on the polarization reversal theory, the interfacial capacitance ( ${C}_{i}$ ) and coercive field ( ${E}_{c}$ ) were calculated in the case of the devices with MoO x electrodes, indicating that the MoO x electrode can minimize the thickness of the non-ferroelectric dead layer at the bottom interface. These results are expected to provide a new way out to optimize the interface quality and ferroelectricity in HZO-based capacitors and ferroelectric memory.