Yong-Seok Lee

Prof. Yong-Seok Lee

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YLYong-Seok Lee
Yong-Seok Lee
DJDong-Won Jang
Dong-Won Jang
The feasibility of a neural network method was discussed in terms of a self-tuning proportional–integral–derivative (PID) controller. The proposed method was configured with two neural networks to dramatically reduce the number of tuning attempts with a practically achievable small amount of data acquisition. The first network identified the target system from response data, previous PID parameters, and response characteristics. The second network recommended PID parameters based on the results of the first network. The results showed that it could recommend PID parameters within 2 s of observing responses. When the number of trained data was as low as 1000, the performance efficiency of these methods was 92.9%, and the tuning was completed in an average of 2.94 attempts. Additionally, the robustness of these methods was determined by considering a system with noise or a situation when the target position was modified. These methods are also applicable for traditional PID controllers, thus enabling conservative industries to continue using PID controllers.

28 January 2022 in Mechanics of Materials
Verified
Journal Article
Closed access
YLYong-Seok Lee
Yong-Seok Lee
SKSeongwoo Kim
Seongwoo Kim
DJDong-Won Jang
Dong-Won Jang
SLSoon-Bok Lee
Soon-Bok Lee

25 February 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
JPJuyoung Park
Juyoung Park
Yoona Nur JungYoona Nur Jung
Yoona Nur Jung
KJKyoung-Jun Jang
Kyoung-Jun Jang
SLSang-Kyu Lee
Sang-Kyu Lee
SCSeong-won Choi
Seong-won Choi
KYKwidug Yun
Kwidug Yun
Isotropic shrinkage is critical for producing dimensionally accurate prostheses using zirconia. However, the anisotropic shrinkage of 3D-printed zirconia limits its utility in clinical applications. We aimed to evaluate the impact of specimen axis alterations on the shrinkage of digital light processing (DLP)-printed zirconia. Cubes measuring 10 × 10 × 10 mm3 (similar in size to molar crowns) and cuboids measuring 10 × 10 × 20 mm (similar in size to a three-unit bridge) were manufactured using a DLP 3D printer. Zirconia specimens were pre-sintered at 1300 °C and 1400 °C. The Z-axis of some specimens was switched to the X-axis before the final sintering procedure. The X-axis, Y-axis, and Z-axis lengths of the green body, pre-sintered block, and fully sintered block were measured using digital calipers. The 3D-printed specimens showed lower shrinkage and higher deviation than the milled specimens, whose shrinkage rate was 26%. The shrinkage rates of the 3D-printed cubic specimens were 19.9% (length), 20.0% (width), and 21.99% (height), while those of the cuboidal specimens were 20.26%, 19.72%, and 21.81%, respectively. For the 3D-printed specimens, which shrink anisotropically during sintering, the axis change step had no significant impact on the shrinkage rate. In all groups, the shrinkage rate along the building direction during printing significantly exceeded that along the gravity direction during sintering.

8 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JPJinhyoung Park
Jinhyoung Park
HCHanchul Cho
Hanchul Cho
YLYong-Seok Lee
Yong-Seok Lee
Energy harvesting, especially for powering low-power internet-of-things (IoT) devices, is gaining attention in recent years. Triboelectric nanogenerators have been studied to improve the output by applying a structure that can concentrate electrons on the surface of the generator materials. For enhancing the triboelectrification output, we herein focused on the power output line. A method for increasing the amount of electrons on the power lead by potential difference and their acceleration was studied. A rod was shaken by external vibrations; the accumulated charges were discharged in a manner similar to that of a lightning rod. Micro plasma was generated when the rod made contact with the mating micro-cracked surface innumerable times. The micro-cracked surface was fabricated with a diamond tip moving horizontally to the surface. As the resistance of the micro plasma was close to zero, the amount of electron movement was instantaneously accelerated. This type of triboelectric generator can be fabricated in the form of an electric box. By using this triboelectric power amplifier, voltage can be amplified 2 to 3 times, and the current can be amplified 10 to 15 times; thus, enhanced energy harvesting efficiency is attained.

5 October 2024 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
HKHyeonjune Kim
Hyeonjune Kim
YLYong-Seok Lee
Yong-Seok Lee

19 June 2025 in Frontiers in Nanotechnology
Verified
Journal Article
Open access
PDF file
JKJaewon Kim
Jaewon Kim
KKKyung Su Kim
Kyung Su Kim
SKSeungbin Kim
Seungbin Kim
YLYong-Seok Lee
Yong-Seok Lee
JKJahyun Koo
Jahyun Koo
The electrode, interfacing with soft tissue, is vulnerable to mechanical failure caused by dynamic organ motions such as cardiac activity, respiration, and digestion. Mechanical mismatch can also lead to tissue damage and sensor displacement. However, existing strategies for conformal integration often fall short of preserving mechanical compliance across large-area, multi-electrode arrays. Most internal organs undergo complex, anisotropic volumetric expansion from physiological activity, requiring implanted systems that can withstand multidirectional strains without inducing stress concentration. Conventional elastomers and mesh-structured electrodes typically exhibit a positive Poisson’s ratio, which hinders multidirectional uniform stretching and results in mechanical mismatch at the tissue–electrode interface. This mismatch not only increases local mechanical load but also leads to electrode displacement. In this study, we propose a conformal electrode design that incorporates a re-entrant geometry into a stretchable and biodegradable polyurethane substrate. Mechanical testing confirmed that this geometry enhances stretchability and reduces the effective modulus of the electrode by approximately 64%. Furthermore, the device maintained electrical stability under cyclic deformation and preserved its structural integrity under dynamic, organ-mimicking volumetric expansion. This mechanical and electrical robustness highlights the potential of the proposed design for long-term integration into implantable electrode arrays for physiological monitoring and disease diagnosis on dynamic three-dimensional organ motion.