Yoona Nur Jung

Dr. Yoona Nur Jung

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
JPJuyoung Park
Juyoung Park
Yoona Nur JungYoona Nur Jung
Yoona Nur Jung
KJKyoung-Jun Jang
Kyoung-Jun Jang
SLSang-Kyu Lee
Sang-Kyu Lee
SCSeong-won Choi
Seong-won Choi
KYKwidug Yun
Kwidug Yun
Isotropic shrinkage is critical for producing dimensionally accurate prostheses using zirconia. However, the anisotropic shrinkage of 3D-printed zirconia limits its utility in clinical applications. We aimed to evaluate the impact of specimen axis alterations on the shrinkage of digital light processing (DLP)-printed zirconia. Cubes measuring 10 × 10 × 10 mm3 (similar in size to molar crowns) and cuboids measuring 10 × 10 × 20 mm (similar in size to a three-unit bridge) were manufactured using a DLP 3D printer. Zirconia specimens were pre-sintered at 1300 °C and 1400 °C. The Z-axis of some specimens was switched to the X-axis before the final sintering procedure. The X-axis, Y-axis, and Z-axis lengths of the green body, pre-sintered block, and fully sintered block were measured using digital calipers. The 3D-printed specimens showed lower shrinkage and higher deviation than the milled specimens, whose shrinkage rate was 26%. The shrinkage rates of the 3D-printed cubic specimens were 19.9% (length), 20.0% (width), and 21.99% (height), while those of the cuboidal specimens were 20.26%, 19.72%, and 21.81%, respectively. For the 3D-printed specimens, which shrink anisotropically during sintering, the axis change step had no significant impact on the shrinkage rate. In all groups, the shrinkage rate along the building direction during printing significantly exceeded that along the gravity direction during sintering.

3 September 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
JKJihyun Kim
Jihyun Kim
Yoona Nur JungYoona Nur Jung
Yoona Nur Jung
YLYong-Seok Lee
Yong-Seok Lee
SCSeong-won Choi
Seong-won Choi
Geelsu HwangGeelsu Hwang
Geelsu Hwang
KYKwidug Yun
Kwidug Yun
The surface treatments and various magnesium alloys are applied to improve the fast degradation rate and resulting negative effects of magnesium alloys. This study aimed to assess the effect of anodic oxidation treatment of magnesium–calcium (Mg-Ca) systems by creating artificial bone defects in the tibia of rats. The cylinder magnesium implants were fabricated using a Mg-xCa (x = 0, 1, 5 wt.%) binary alloy. Degradability and new bone formation were observed at two and six weeks using micro-CT. Histomorphometric parameters were evaluated with Goldner’s trichrome staining. The degradation rate decreased depending on the amount of calcium added. The parameters related to bone formation revealed an increasing pattern depending on the addition of calcium, anodic oxidation, and time. The amount of absorbed magnesium to assess degradability of magnesium implants by the histomorphometric analysis revealed a high value in the untreated group at two and six weeks. Bone healing parameters increased depending on the amount of calcium added, anodic oxidation treatment, and region of interest (ROI—0.5 mm, 1.00 mm, 1.5 mm, and 2.0 mm). Biodegradable magnesium systems have the potential to replace bone screws and plates. Combination with calcium combined with anodization surface treatment can improve initial corrosion resistance and promote bone formation.

Verified
Journal Article
Open access
PDF file
PZPeng Zhang
Peng Zhang
MZMeiling Zhang
Meiling Zhang
Yoona Nur JungYoona Nur Jung
Yoona Nur Jung
SCSeong-Won Choi
Seong-Won Choi
YLYong-Seok Lee
Yong-Seok Lee
KYKwidug Yun
Kwidug Yun
Recent advancements in three-dimensional (3D) printing technology, particularly digital light processing (DLP) 3D printing, have enabled the customization of bone substitutes with specific shapes that match bone defect sizes and geometries. Magnesium calcium phosphate (MCP) has gained considerable attention due to its strong mechanical properties, degradability, and ability to promote bone regeneration. In this study, we prepared MCP samples with five different molar ratios via DLP 3D printing. We analyzed the physicochemical properties of these five groups, including phase compositions and microstructures, which were examined using X-ray diffraction and scanning electron microscopy, respectively. Additionally, we assessed the effects of MCP on material density and shrinkage. Biaxial flexural strength and degradation rate were evaluated; biological properties were examined through WST-8 analysis and alkaline phosphatase activity assays. Among the tested samples, MCP1/1 exhibited the highest strength. A higher proportion of magnesium phosphate in MCP corresponded to an increased degradation rate. Cell response observations in the WST-8 assay indicated that cell proliferation was better in the MCP1/1 group than in the other groups on days 4 and 7 of culturing. Alkaline phosphatase activity assays demonstrated that MCP1/1 exhibited higher activity than calcium phosphate. Our findings suggest that MCP1/1 can be used effectively in bone-tissue-engineering applications.

1 January 2026 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
BHBetül Hwang
Betül Hwang
NMNicolas Müller
Nicolas Müller
Yoona Nur JungYoona Nur Jung
Yoona Nur Jung
JCJisu Choi
Jisu Choi
JLJung-seok Lee
Jung-seok Lee

12 May 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
Yoona Nur JungYoona Nur Jung
Yoona Nur Jung
SHSeoung-Jin Hong
Seoung-Jin Hong
JKJaeyoung Kim
Jaeyoung Kim
Hyeonjong LeeHyeonjong Lee
Hyeonjong Lee
Background and ObjectivesMechanical complications in the implant–abutment–screw complex compromise long-term clinical reliability and are influenced by preload-dependent stress distribution. However, the effect of preload magnitude on the internal stress distribution within implant components remains insufficiently characterized. This study aimed to identify a biomechanically relevant preload range that optimizes mechanical stability and to evaluate the stress distribution in implant components and the surrounding bone.MethodsNine three-dimensional finite element models were developed in a parametric analysis to simulate preload levels ranging from 1 N to 700 N. A two-stage loading protocol was applied, consisting of an initial stage in which a specified preload was imposed, followed by a 100-N oblique occlusal load. Von Mises stress and crown deformation were evaluated.ResultsThe maximum von Mises stress increased with preload and was localized at the coronal section of the implant–abutment–screw junction. Within the abutment, stress shifted from the apical region toward the notch and interface regions as preload increased. Crown deformation decreased with increasing preload and plateaued at preload levels ≥ 400 N. Stress changes in both cortical and cancellous bone were minimal.ConclusionsPreload levels between 200 and 400 N produced favorable stress redistribution and reduced crown deformation. This range represents a biomechanically optimal window for mechanical stability of implant components and provides a computationally derived reference for preload selection in implant systems.