Isotropic shrinkage is critical for producing dimensionally accurate prostheses using zirconia. However, the anisotropic shrinkage of 3D-printed zirconia limits its utility in clinical applications. We aimed to evaluate the impact of specimen axis alterations on the shrinkage of digital light processing (DLP)-printed zirconia. Cubes measuring 10 × 10 × 10 mm3 (similar in size to molar crowns) and cuboids measuring 10 × 10 × 20 mm (similar in size to a three-unit bridge) were manufactured using a DLP 3D printer. Zirconia specimens were pre-sintered at 1300 °C and 1400 °C. The Z-axis of some specimens was switched to the X-axis before the final sintering procedure. The X-axis, Y-axis, and Z-axis lengths of the green body, pre-sintered block, and fully sintered block were measured using digital calipers. The 3D-printed specimens showed lower shrinkage and higher deviation than the milled specimens, whose shrinkage rate was 26%. The shrinkage rates of the 3D-printed cubic specimens were 19.9% (length), 20.0% (width), and 21.99% (height), while those of the cuboidal specimens were 20.26%, 19.72%, and 21.81%, respectively. For the 3D-printed specimens, which shrink anisotropically during sintering, the axis change step had no significant impact on the shrinkage rate. In all groups, the shrinkage rate along the building direction during printing significantly exceeded that along the gravity direction during sintering.
The surface treatments and various magnesium alloys are applied to improve the fast degradation rate and resulting negative effects of magnesium alloys. This study aimed to assess the effect of anodic oxidation treatment of magnesium–calcium (Mg-Ca) systems by creating artificial bone defects in the tibia of rats. The cylinder magnesium implants were fabricated using a Mg-xCa (x = 0, 1, 5 wt.%) binary alloy. Degradability and new bone formation were observed at two and six weeks using micro-CT. Histomorphometric parameters were evaluated with Goldner’s trichrome staining. The degradation rate decreased depending on the amount of calcium added. The parameters related to bone formation revealed an increasing pattern depending on the addition of calcium, anodic oxidation, and time. The amount of absorbed magnesium to assess degradability of magnesium implants by the histomorphometric analysis revealed a high value in the untreated group at two and six weeks. Bone healing parameters increased depending on the amount of calcium added, anodic oxidation treatment, and region of interest (ROI—0.5 mm, 1.00 mm, 1.5 mm, and 2.0 mm). Biodegradable magnesium systems have the potential to replace bone screws and plates. Combination with calcium combined with anodization surface treatment can improve initial corrosion resistance and promote bone formation.