Marta Freire

Marta Freire

Auto-generated profile, based on publicly available information

Marta Freire

Instituto de Instrumentación para Imagen Molecular, and the Centro Mixto CSIC, Universitat Politècnica de València

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
MFM Freire
M Freire
JBJ Barrio
J Barrio
NCN Cucarella
N Cucarella
CVC Valladares
C Valladares
AGA Gonzalez-Montoro
A Gonzalez-Montoro
AGAntonio J. Gonzalez
Antonio J. Gonzalez
Objective . The goal of this work is to experimentally compare the 3D spatial and energy resolution of a semi-monolithic detector suitable for total-body positron emission tomography (TB-PET) scanners using different surface crystal treatments and silicon photomultiplier (SiPM) models. Approach . An array of 1 × 8 lutetium yttrium oxyorthosilicate (LYSO) slabs of 25.8 × 3.1 × 20 mm 3 separated with Enhanced Specular Reflector (ESR) was coupled to an array of 8 × 8 SiPMs. Three different treatments for the crystal were evaluated: ESR + RR + B , with lateral faces black (B) painted and a retroreflector (RR) layer added to the top face; ESR + RR , with lateral faces covered with ESR and a RR layer on the top face and; All ESR, with lateral and top sides with ESR. Additionally, two SiPM array models from Hamamatsu Photonics belonging to the series S13361-3050AE-08 (S13) and S14161-3050AS-08 (S14) have been compared. Coincidence data was experimentally acquired using a 22 Na point source, a pinhole collimator, a reference detector and moving the detector under study in 1 mm steps in the x - and DOI - directions. The spatial performance was evaluated by implementing a neural network (NN) technique for the impact position estimation in the x - (monolithic) and DOI directions. Results . Energy resolution values of 16 ± 1%, 11 ± 1%, 16 ± 1%, 15 ± 1%, and 13 ± 1% were obtained for the S1 3- ESR + B + RR, S1 3-All ESR, S14- ESR + B + RR, S14- ESR + RR , and S14- All ESR, respectively. Regarding positioning accuracy, mean average error of 1.1 ± 0.5, 1.3 ± 0.5 and 1.3 ± 0.5 were estimated for the x - direction and 1.7 ± 0.8, 2.0 ± 0.9 and 2.2 ± 1.0 for the DOI - direction, for the ESR + B + RR, ESR + RR and All ESR cases, respectively, regardless of the SiPM model. Significance . Overall, the obtained results show that the proposed semi-monolithic detectors are good candidates for building TB-PET scanners.

16 October 2019 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
MFMarta Freire
Marta Freire
AGAndrea Gonzalez-Montoro
Andrea Gonzalez-Montoro
FSFilomeno Sanchez
Filomeno Sanchez
JBJose M. Benlloch
Jose M. Benlloch
AGAntonio J. Gonzalez
Antonio J. Gonzalez
Molecular imaging systems, such as positron emission tomography (PET), use detectors providing energy and a 3-D interaction position of a gamma ray within a scintillation block. Monolithic crystals are becoming an alternative to crystal arrays in PET. However, calibration processes are required to correct for nonuniformities, mainly produced by the truncation of the scintillation light distribution at the edges. We propose a calibration method based on the Voronoi diagrams. We have used 50 × 50 × 15 mm3 LYSO blocks coupled to a 12 × 12 SiPMs array. We have first studied two different interpolation algorithms: 1) weighted average method (WAM) and 2) natural neighbor (NN). We have compared them with an existing calibration based on 1-D monomials. Here, the crystal was laterally black painted and a retroreflector (RR) layer added to the entrance face. The NN exhibited the best results in terms of XY impact position, depth of Interaction, and energy, allowing us to calibrate the whole scintillation volume. Later, the NN interpolation has been tested against different crystal surface treatments, allowing always to correct edge effects. Best energy resolutions were observed when using the reflective layers (12%- 14%). However, better linearity was observed with the treatments using black paint. In particular, we obtained the best overall performance when lateral black paint is combined with the RR.

1 December 2022 in Bio-Algorithms and Med-Systems
Verified
Journal Article
Open access
PDF file
AGAndrea Gonzalez-Montoro
Andrea Gonzalez-Montoro
JBJulio Barbera
Julio Barbera
DGDavid Sanchez Gonzalo
David Sanchez Gonzalo
AMAlvaro Mondejar
Alvaro Mondejar
MFMarta Freire
Marta Freire
JBJose M. Benlloch
Jose M. Benlloch
In this article, we present the geometrical design and preliminary results of a high sensitivity organ-specific Positron Emission Tomography (PET) system dedicated to the study of the human brain. The system, called 4D-PET, will allow accurate imaging of brain studies due to its expected high sensitivity, high 3D spatial resolution and, by including precise photon time of flight (TOF) information, a boosted signal-to-noise ratio (SNR). The 4D-PET system incorporates an innovative detector design based on crystal slabs (semi-monolithic) that enables accurate 3D photon impact positioning (including photon Depth of Interaction (DOI) measurement), while providing a precise determination of the photon arrival time to the detector. The detector includes a novel readout system that reduces the number of detector signals in a ratio of 4:1 thus, alleviating complexity and cost. The analog output signals are fed to the TOFPET2 ASIC (PETsys) for scalability purposes. The present manuscript reports the evaluation of the 4D-PET detector, achieving best values 3D resolution values of <1.6 mm (pixelated axis), 2.7±0.5 mm (monolithic axis) and 3.4±1.1 (DOI axis) mm; 359 ± 7 ps coincidence time resolution (CTR); 10.2±1.5 % energy resolution; and sensitivity of 16.2% at the center of the scanner (simulated). Moreover, a comprehensive description of the 4D-PET architecture (that includes 320 detectors), some pictures of its mechanical assembly, and simulations on the expected image quality are provided.

21 June 2022 in Medical Physics
Verified
Journal Article
Open access
MFMarta Freire
Marta Freire
SESara Echegoyen
Sara Echegoyen
AGAndrea Gonzalez‐Montoro
Andrea Gonzalez‐Montoro
FSFilomeno Sanchez
Filomeno Sanchez
AGAntonio J. Gonzalez
Antonio J. Gonzalez
Background: Significant interest has been recently shown for using monolithic scintillation crystals in molecular imaging systems, such as positron emission tomography (PET) scanners. Monolithic‐based PET scanners result in a lower cost and higher sensitivity, in contrast to systems based on the more conventional pixellated configuration. The monolithic design allows one to retrieve depth‐of‐interaction information of the impinging 511 keV photons without the need for additional hardware materials or complex positioning algorithms. However, the so‐called edge‐effect inherent to monolithic‐based approaches worsens the detector performance toward the crystal borders due to the truncation of the light distribution, thus decreasing positioning accuracy.Purpose: The main goal of this work is to experimentally demonstrate the detector performance improvement when machine‐learning artificial neural‐network (NN) techniques are applied for positioning estimation in multiple monolithic scintillators optically coupled side‐by‐side.Methods: In this work, we show the performance evaluation of two LYSO crystals of 33 × 25.4 × 10 mm3optically coupled by means of a high refractive index adhesive compound (Meltmount, refractive indexn = 1.70). A 12 × 12 silicon photomultiplier array has been used as photosensor. For comparison, the same detector configuration was tested for two additional coupling cases: (1) optical grease (n = 1.46) in between crystals, and (2) isolated crystals using black paint with an air gap at the interface (named standard configuration). Regarding 2D photon positioning (XY plane), we have tested two different methods: (1) a machine‐learning artificial NN algorithm and (2) a squared‐charge (SC) centroid technique.Results: At the interface region of the detector, the SC method achieved spatial resolutions of 1.7 ± 0.3, 2.4 ± 0.3, and 2.6 ± 0.4 mm full‐width at half‐maximum (FWHM) for the Meltmount, grease, and standard configurations, respectively. These values improve to 1.0 ± 0.2, 1.2 ± 0.2, and 1.2 ± 0.3 mm FWHM when the NN algorithm was employed. Regarding energy performance, resolutions of 18 ± 2%, 20 ± 2%, and 23 ± 3% were obtained at the interface region of the detector for Meltmount, grease, and standard configurations, respectively.Conclusions: The results suggest that optically coupling together scintillators with a high refractive index adhesive, in combination with an NN algorithm, reduces edge‐effects and makes it possible to build scanners with almost no gaps in between detectors.

1 August 2023 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
JBJohn Barrio
John Barrio
NCNeus Cucarella
Neus Cucarella
MFMarta Freire
Marta Freire
CVCelia Valladares
Celia Valladares
JBJose M. Benlloch
Jose M. Benlloch
AGAntonio J. Gonzalez
Antonio J. Gonzalez
The use of detectors based on semi-monolithic crystals can be of interest to clinical PET scanners due to their time of flight (TOF) and depth of interaction (DOI) capabilities. In this work, timing and energy characterization of four different detector configurations based on arrays of 8 LYSO slabs of 25.4×3.1×20 mm each coupled to SiPMs have been carried out. On the one hand, two different surface treatments have been studied. In one configuration, all the slab surfaces were treated with ESR (named ESR). In the other configuration, a retroreflector layer was added to the entrance face and the pixelated external faces were painted black (named ESR+B+RR). On the other hand, two different SiPM array models belonging to the series S13 and S14 from Hamamatsu Photonics were also compared. In all cases, the readout was performed by the TOFPET2 ASIC. The results show an energy resolution and a detector time resolution (DTR) as good as 12.5% and 193 ps, respectively, for the ESR treatment and the S13 photosensor. For the ESR+B+RR treatment and S13, the energy resolution and DTR are 14.6% and 238 ps, respectively. When using the S14, the energy resolutions and DTRs are, respectively, 11.6% and 219 ps for the ESR treatment, and 14.2% and 339 ps for the ESR+B+RR treatment.

1 November 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
MFMarta Freire
Marta Freire
AGAndrea Gonzalez-Montoro
Andrea Gonzalez-Montoro
GCGabriel Canizares
Gabriel Canizares
ARAhmadreza Rezaei
Ahmadreza Rezaei
JNJohan Nuyts
Johan Nuyts
AGAntonio J. Gonzalez
Antonio J. Gonzalez
Improving sensitivity and spatial resolution in small animal positron emission tomography imaging instrumentation constitutes one of the main goals of nuclear imaging research. These parameters are degraded by the presence of gaps between the detectors. The present manuscript experimentally validates our prototype of an edge-less preclinical PET system based on a single LYSO:Ce annulus with an inner diameter of 62 mm and ten outer facets of $26\times52$ mm 2 . Scintillation light is read out by arrays of $8\times8$ SiPMs coupled to the facets, using a projection readout of the rows and columns signals. The readout provides an accurate depth of interaction (DOI). We have implemented a calibration that mitigates the DOI-dependency of the transaxial and axial impact coordinates, and the energy photopeak gain. An energy resolution of 23.4 ± 1.8% was determined. The average spatial resolution of 1.4 ± 0.2 and 1.3 ± 0.4 mm FWHM were achieved for the radial and axial directions, respectively. We found a peak sensitivity of 3.8% at the system center, and a maximum NECR at 40.6 kcps for 0.27 mCi. The image quality (IQ) was evaluated using reconstructed images of an array of sources and the NEMA IQ phantom was also studied.