This paper proposes a novel methodology to estimate equivalent inertia of an area, observed from its boundary buses where Phasor Measurement Units (PMUs) are assumed to be installed. The areas are divided according to the measurement points, and the methodology proposed can obtain the equivalent dynamic response of the area dependent of or independent of coherency of the generators inside, which is the first contribution of this paper. The methodology is divided in three parts: estimating the frequency response, estimating the power imbalance and estimating inertia through the solution of the swing equation by Least-Squares Method (LSM). The estimation of the power imbalance is the second contribution of this paper, enabling the study of areas that contain perturbations and attending the limitation of methods of the literature that rely on assumptions of slow mechanical power. It can be further divided in three steps: accounting the total power injected, estimating an equivalent load behavior and estimating an equivalent mechanical power. The quality of results is proved with test systems of different sizes, simulating different types of perturbations.
28 April 2022 in International Journal of Electrical Power & Energy Systems
This paper presents the application of a methodology for estimating the inertia of generator groups of the Brazilian Interconnected Power System (BIPS) using phasor measurement unit (PMU) data acquired at 230 kV transmission substations. The methodology has been applied using synchrophasor data collected during disturbances in a Brazilian subsystem with two hydroelectric power plants (HPPs), as well as two interconnections with the rest of the BIPS, composed of three 230 kV transmission lines and a back-to-back converter station. Simulated and real data have been analyzed to assess the limitations and to identify required improvements toward a practical application of the perturbation-based methodology in the estimation of the inertia of real systems. A by-product of the application of the methodology is the obtaining of a second-order dynamic equivalent, useful for model-based online applications.
In this paper, a methodology for validating and calibrating dynamic models in large interconnected power systems using synchronized measurements, is presented. The approach combines topological cuts at several hierarchical levels with Hybrid Dynamic Simulation (HDS), allowing the systematic validation of network partitions or indication of partitions with model inaccuracies. Discrepancy indicators computed from Phasor Measurement Units (PMU) data are employed for both, validation and detection of modeling inaccuracies. Once discrepancies are located, a calibration procedure is applied, which is formulated as an optimization problem and solved using Genetic Algorithms. The methodology is assessed on a test system using synthetic measurements and on the Brazilian Interconnected Power System (BIPS) using real disturbance records. The results indicate the effectiveness of the proposed methodology for model validation, the identification of inaccuracy sources, and model calibration.