Poor air quality is a global problem that affects human health and ecosystems all over the world. For that reason, many countries invest in networks of reference monitoring stations that measure air quality in real time. However, the high installation and maintenance costs of these stations mean that smaller cities or underdeveloped regions are less covered by such stations. In these regions, alternative detection technologies such as low-cost monitoring systems can be used instead. Unfortunately, the results of such monitoring devices are often questioned by academics. This contribution proposes the design of an air quality monitoring system where cost and reliability have been optimized from a hardware point of view. In addition, the device has been coupled to an IoT platform so that inexperienced users can view and share the collected information The design of affordable systems increases the ability to perform ad hoc analysis at the level of neighborhoods or cities by citizen science organizations or governmental entities.
In the Western world, the SO2 concentration in ambient air dropped to low levels, but some emission sources (e.g., merchant ships) and some regions (e.g., low-income countries) still emit substantial amounts of SO2. At those locations, SO2 monitoring is critical. However, low-income countries do not have much access to expensive reference instruments. Low-cost gas sensors might be an alternative, but it is unclear how reliable such measurements are. To evaluate the performance of the low-cost alternative, the same SO2 gas sensor has been subjected to three different calibration methods: (1) low-cost calibration performed in the tropical climate of Cuba; (2) high-end calibration performed in Belgium; (3) a field calibration at an air quality measuring station in Belgium. The first two methods showed similar trends, suggesting that the gas sensor can be calibrated with a low-cost method. The field calibration was hampered by the low SO2 concentrations. For the monitoring campaign in Cienfuegos, Cuba, the low-cost SO2 sensor calibrated by the low-cost method appeared to be sufficiently reliable. The reliability of the sensor increases with the increase in SO2 concentration, so it can be used in Cuba instead of Belgium.
This contribution shows the possibilities of applying a low-cost, multi-purpose data logger built around an Arduino Mega 2560 single-board computer. Most projects use this kind of hardware to develop single-purpose data loggers. In this work, a data logger with a more general hardware and software architecture was built to perform measurement campaigns in very different domains. The wide applicability of this data logger was demonstrated with short-term monitoring campaigns in relation to outdoor air quality, human activity in an office, motion of a journey on a bike, and exhaust gas monitoring of a diesel generator. In addition, an assessment process and corresponding evaluation framework are proposed to assess the credibility of low-cost scientific devices built in-house. The experiences acquired during the development of the system and the short measurement campaigns were used as inputs in the assessment process. The assessment showed that the system scores positively on most product-related targets. However, unexpected events affect the assessment over the longer term. This makes the development of low-cost scientific devices harder than expected. To assure stability and long-term performance of this type of design, continuous evaluation and regular engineering corrections are needed throughout longer testing periods.
This contribution shows the possibilities of a low-cost multipurpose data logger that was built around an Arduino Mega 2560 single board computer. To transform the Arduino Mega into such a data logger, a sensor shield was designed that contains an SD-card, real-time clock, and different kinds of connectors so that sensors can easily be attached to the device. The software considers a wide range of predefined sensors from which a user can choose. To assess the performance of such a device, short-term monitoring campaigns in relation to outdoor air quality, human activity in an office, motion of a journey on a bike, and exhaust gas monitoring of a diesel generator were realized. Besides the possibilities to apply the data logger in different kinds of applications, a method is proposed to assess the credibility of such a system. The assessment based on the various short-term campaigns showed that the system scores positively on most of the performance indicators, but that unexpected (black swan) events affect the assessment over the longer term. This makes the development of low-cost scientific instruments harder than expected. The stability and long-term performance of this type of design requires continuous evaluation and engineering correction.
Particulate matter (PM) is widely recognized as a major air pollutant with significant impacts on human health, highlighting the need for accurate monitoring. In developing countries, low-cost sensors are crucial for accessible PM monitoring, but their accuracy and reliability must first be assessed. This study benchmarked the Alphasense OPC-N3 and Next PM sensors through laboratory and field evaluations. Laboratory tests were performed in controlled conditions with HEPA-filtered air at low humidity and varying concentrations of water droplets from nebulized deionized water. A 27-day field study in Cienfuegos, Cuba, provided additional insights into real-world performance. The OPC-N3 showed susceptibility to perturbations and was more affected by outliers (especially PM10), relative humidity, and interference from aqueous aerosols. In contrast, the Next PM sensor demonstrated superior stability, lower noise levels, and consistent performance across different environmental conditions. Despite a substantial price difference, both sensors provided valid measurements. Additionally, both sensors produced lognormal PM concentration distributions during field campaigns. This feature could aid in addressing the calibration stability challenges commonly associated with low-cost sensors through in situ calibration methods. While the PM measurements by affordable sensors are not perfect, they are sufficiently reliable for supporting air quality assessments in resource-limited settings.