The present numerical investigation identifies quantitative effects of fundamental controlling parameters on the detachment characteristics of isolated bubbles in cases of pool boiling in the nucleate boiling regime. For this purpose, an improved Volume of Fluid (VOF) approach, developed previously in the general framework of OpenFOAM Computational Fluid Dynamics (CFD) Toolbox, is further coupled with heat transfer and phase change. The predictions of the model are quantitatively verified against an existing analytical solution and experimental data in the literature. Following the model validation, four different series of parametric numerical experiments are performed, exploring the effect of the initial thermal boundary layer (ITBL) thickness for the case of saturated pool boiling of R113 as well as the effects of the surface wettability, wall superheat and gravity level for the cases of R113, R22 and R134a refrigerants. It is confirmed that the ITBL is a very important parameter in the bubble growth and detachment process. Furthermore, for all of the examined working fluids the bubble detachment characteristics seem to be significantly affected by the triple-line contact angle (i.e., the wettability of the heated plate) for equilibrium contact angles higher than 45°. As expected, the simulations revealed that the heated wall superheat is very influential on the bubble growth and detachment process. Finally, besides the novelty of the numerical approach, a last finding is the fact that the effect of the gravity level variation in the bubble detachment time and the volume diminishes with the increase of the ambient pressure.
Liquid penetration analysis in porous media is of great importance in a wide range of applications such as ink jet printing technology, painting and textile design. This article presents an investigation of droplet impingement onto metallic meshes, aiming to provide insights by identifying and quantifying impact characteristics that are difficult to measure experimentally. For this purpose, an enhanced Volume-Of-Fluid (VOF) numerical simulation framework is utilised, previously developed in the general context of the OpenFOAM CFD Toolbox. Droplet impacts on metallic meshes are performed both experimentally and numerically with satisfactory degree of agreement. From the experimental investigation three main outcomes are observed—deposition, partial imbibition, and penetration. The penetration into suspended meshes leads to spectacular multiple jetting below the mesh. A higher amount of liquid penetration is linked to higher impact velocity, lower viscosity and larger pore size dimension. An estimation of the liquid penetration is given in order to evaluate the impregnation properties of the meshes. From the parametric analysis it is shown that liquid viscosity affects the adhesion characteristics of the drops significantly, whereas droplet break-up after the impact is mostly controlled by surface tension. Additionally, wettability characteristics are found to play an important role in both liquid penetration and droplet break-up below the mesh.
1 March 2014 in International Journal of Sediment Research
The ongoing discharge of containments into the environment has raised concerns about the potential harm they pose to various organisms. In the framework of eliminating pharmaceutical chemicals from aqueous solutions, enzymatic degradation by laccase is an environmentally friendly option. In this investigation, laccase immobilized on biochar derived from agricultural waste (orange peels, OPs) was used for the first time to remove carbamazepine and diclofenac from aqueous media. Different characterizations, such as Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy and energy dispersive X-ray spectroscopy (SEM-EDS), X-Ray diffraction (XRD), specific surface area (SBET), Boehm titration, proximate and ultimate analysis, as well as the point of zero-charge (pHPZC) analysis, were used in this study. The immobilization of laccase results in enhanced stability with respect to storage, temperature, and pH compared to laccase in its free form. The findings showed that the ideal conditions for immobilization were a pH of 4, a temperature of 30 °C, and a laccase concentration of 4.5 mg/mL. These parameters led to an immobilization yield of 63.40%. The stability of laccase immobilized on biochar derived from orange peels (LMOPs) was assessed over a period of 60 days, during which they preserved 60.2% and 47.3% of their initial activities when stored at temperatures of 25 °C and 4 °C, respectively. In contrast, free laccase exhibited lower stability, with only 33.6% and 15.4% of their initial activities maintained under the same storage conditions. Finally, the use of immobilized laccase proved to be effective in eliminating these pollutants in up to five cycles. Upon comparing the two systems, namely LMOPs and modified orange peels (MOPs), it becomes apparent that LMOPs exhibit an estimated 20% improvement in removal efficiency. These results affirmed the viability of activated carbon derived from OPs as a cost-effective option for immobilizing laccase. This approach could potentially be further scaled up to effectively eliminate organic pollutants from water sources.
The key concept in wound dressing design and development is the fact that keeping a wound moist accelerates healing. Therefore, the selection of the appropriate wound dressing type is vital. The absorption of wound exudate by wound dressings can be considered as a microfluidic phenomenon that can be investigated either by performing high resolution laboratory experiments or by utilizing high resolution Computational Fluid Dynamics numerical simulations. As an initial step, in the present paper, the effects of the pore size (wound dressing porosity), the liquid (wound exudate) viscosity, and the initial droplet diameter are numerically investigated using a simplified analog of the phenomenon that consists of a quasi-sessile droplet being absorbed by a single cylindrical pore. For this purpose, an enhanced Volume Of Fluid model, developed in the general context of OpenFOAM, is validated and applied. It is found that distinct droplet absorption rates exist with specific relationships derived using best-fit lines that can predict the absorption rates for particular values of pore size and liquid viscosity. For the examined Eo and Oh number ranges (0.0015 < Eo < 0.15 and 0.0035 < Oh < 0.095), these distinct droplet absorption rates are directly linked with four different droplet evolution regimes that are grouped in a well-defined flow map. Finally, it is shown that the resulting liquid absorption rates are not significantly affected by the initial droplet diameter and that an appropriate wound dressing porosity can be selected by an estimation of the wound exudate physical properties.
Phase change heat transfer within microchannels is considered one of the most promising cooling methods for the efficient cooling of high-performance electronic devices. However, there are still fundamental parameters, such as the effect of channel hydraulic diameter whose effects on fluid flow and heat transfer characteristics are not clearly defined yet. The objective of the present work is to numerically investigate the first transient flow boiling characteristics from the bubble inception up to the first stages of the flow boiling regime development, in rectangular microchannels of varying hydraulic diameters, utilising an enhanced custom VOF-based solver. The solver accounts for conjugate heat transfer effects, implemented in OpenFOAM and validated in the literature through experimental results and analytical solutions. The numerical study was conducted through two different sets of simulations. In the first set, flow boiling characteristics in four single microchannels of = 50, 100, 150, and 200 with constant channel aspect ratio of 0.5 and length of 2.4 were examined. Due to the different , the applied heat and mass flux values varied between 20 to 200 and 150 to 2400 , respectively. The results of the two-phase simulations were compared with the corresponding initial single-phase stage of the simulations, and an increase of up to 37.4% on the global Nu number was revealed. In the second set of simulations, the effectiveness of having microchannel evaporators of single versus multiple parallel microchannels was investigated by performing and comparing simulations of a single rectangular microchannel with of 200 and four-parallel rectangular microchannels, each having a hydraulic diameter of 50 . By comparing the local time-averaged thermal resistance along the channels, it is found that the parallel microchannels configuration resulted in a 23.3% decrease in the average thermal resistance compared to the corresponding single-phase simulation stage, while the flow boiling process reduced the by only 5.4% for the single microchannel case. As for the developed flow regimes, churn and slug flow dominated, whereas liquid film evaporation and, for some cases, contact line evaporation were the main contributing flow boiling mechanisms.