Background: Structured reporting (SR) in radiology is becoming increasingly necessary and has been recognized recently by major scientific societies. This study aims to build structured CT-based reports in colon cancer during the staging phase in order to improve communication between the radiologist, members of multidisciplinary teams and patients. Materials and methods: A panel of expert radiologists, members of the Italian Society of Medical and Interventional Radiology, was established. A modified Delphi process was used to develop the SR and to assess a level of agreement for all report sections. Cronbach’s alpha (Cα) correlation coefficient was used to assess internal consistency for each section and to measure quality analysis according to the average inter-item correlation. Results: The final SR version was built by including n = 18 items in the “Patient Clinical Data” section, n = 7 items in the “Clinical Evaluation” section, n = 9 items in the “Imaging Protocol” section and n = 29 items in the “Report” section. Overall, 63 items were included in the final version of the SR. Both in the first and second round, all sections received a higher than good rating: a mean value of 4.6 and range 3.6–4.9 in the first round; a mean value of 5.0 and range 4.9–5 in the second round. In the first round, Cronbach’s alpha (Cα) correlation coefficient was a questionable 0.61. In the first round, the overall mean score of the experts and the sum of scores for the structured report were 4.6 (range 1–5) and 1111 (mean value 74.07, STD 4.85), respectively. In the second round, Cronbach’s alpha (Cα) correlation coefficient was an acceptable 0.70. In the second round, the overall mean score of the experts and the sum of score for structured report were 4.9 (range 4–5) and 1108 (mean value 79.14, STD 1.83), respectively. The overall mean score obtained by the experts in the second round was higher than the overall mean score of the first round, with a lower standard deviation value to underline greater agreement among the experts for the structured report reached in this round. Conclusions: A wide implementation of SR is of critical importance in order to offer referring physicians and patients optimum quality of service and to provide researchers with the best quality data in the context of big data exploitation of available clinical data. Implementation is a complex procedure, requiring mature technology to successfully address the multiple challenges of user-friendliness, organization and interoperability.
Since the beginning in December 2019, the SARS-CoV-2 outbreak appeared to affect mostly the adult population, sparing the vast majority of children who only showed mild symptoms. The purpose of this investigation is to assess the status on the mechanisms that give children and infants this variation in epidemiology compared to the adult population and its impact on therapies and vaccines that are aimed towards them. A literature review, including in vitro studies, reviews, published guidelines and clinical trials was performed. Clinical trials concerned topics that allowed a descriptive synthesis to be produced. Four underlying mechanisms were found that may play a key role in providing COVID-19 protection in babies. No guidelines are available yet for therapy due to insufficient data; support therapy remains the most used. Only two vaccines are approved by the World Health Organization to be used in children from 12 years of age, and there are currently no efficacy or safety data for children below the age of 12 years. The COVID-19 clinical frame infection is milder in children and adolescents. This section of the population can act as vectors and reservoirs and play a key role in the transmission of the infection; therefore, vaccines are paramount. More evidence is required to guide safely the vaccination campaign.
Computed tomography angiography (CTA) has been widely used in the diagnostic evaluation of many aortic diseases, but no standardized techniques actually exist for aortic CTA. The aim of this study was to describe the usefulness of triphasic CTA in aortic assessment in both non-traumatic emergency and surveillance conditions. We performed non ECG-gated CTA examinations with a 64-slice CT scanner using a triphasic protocol consisting of an unenhanced acquisition, and two (early and delayed) contrastographic phases with a delay of 25-30 s and 100-120 s respectively after the injection of contrast medium. Were retrospectively selected adult patients with imaging findings of acute aortic dissection (AAD) or endoleak (EL) from November 2012 to November 2014. AAD was detected in 36 (67%) patients: 23 type A-AADs, and 13 type B-AADs. The presence of EL was observed in 18 (33%) patients: 1 type Ia, 5 types IIa, 2 types IIb, 1 type IIIa and 9 types IIIb. Triphasic CTA is useful to provide correct and prompt diagnosis of AAD in emergency, allowing the evaluation of type and atypical forms of AAD, and the identification of possible branch-vessel involvement and complications. During surveillance, triphasic CTA assures accurate and complete assessment of all known and unknown ELs and it is essential for first follow-up examination. Triphasic CTA represents a reliable imaging tool for aortic assessment in both non-traumatic emergency and surveillance after endovascular aneurysm repair. Modified protocol could be employed in selected patients and tailored in their known disease.
Immunotherapy is a promising therapeutic strategy both for solid and hematologic tumors, such as in Hodgkin (HL) and non-Hodgkin lymphoma (NHL). In particular, immune-checkpoint inhibitors, such as nivolumab and pembrolizumab, are increasingly used for the treatment of refractory/relapsed HL. At the same time, evidence of chimeric antigen receptor (CAR)-T-cell immunotherapy efficacy mostly in NHL is growing. In this setting, the challenge is to identify an appropriate imaging method to evaluate immunotherapy response. The role of 18F-Fluorodeoxyglucose (18F-FDG) positron-emission tomography/computed tomography (PET/CT), especially in early evaluation, is under investigation in order to guide therapeutic strategies, taking into account the possible atypical responses (hyperprogression and pseudoprogression) and immune-related adverse events that could appear on PET images. Herein, we aimed to present a critical overview about the role of 18F-FDG PET/CT in evaluating treatment response to immunotherapy in lymphoma patients.