24 April 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MMMischa Mühling
Mischa Mühling
SSSabrina Sandriesser
Sabrina Sandriesser
CGClaudio Glowalla
Claudio Glowalla
SHSven Herrmann
Sven Herrmann
PAPeter Augat
Peter Augat
SHSven Hungerer
Sven Hungerer
Background: Ipsilateral revision surgeries of total hip or knee arthroplasties due to periprosthetic fractures or implant loosening are becoming more frequent in aging populations. Implants in revision arthroplasty usually require long anchoring stems. Depending on the residual distance between two adjacent knee and hip implants, we assume that the risk of interprosthetic fractures increases with a reduction in the interprosthetic distance. The aim of the current study was to investigate the maximum strain within the femoral shaft between two ipsilateral implants tips. Methods: A simplified physical model consisting of synthetic bone tubes and metallic implant cylinders was constructed and the surface strains were measured using digital image correlation. The strain distribution on the femoral shaft was analyzed in 3-point- and 4-point-bending scenarios. The physical model was transferred to a finite element model to parametrically investigate the effects of the interprosthetic distance and the cortical thickness on maximum strain. Strain patterns for all parametric combinations were compared to the reference strain pattern of the bone without implants. Results: The presence of an implant reduced principal strain values but resulted in distinct strain peaks at the locations of the implant tips. A reduced interprosthetic distance and thinner cortices resulted in strain peaks of up to 180% compared to the reference. At low cortical thicknesses, the strain peaks increased exponentially with a decrease in the interprosthetic distance. An increasing cortical thickness reduced the peak strains at the implant tips. Conclusions: A minimum interprosthetic distance of 10 mm seems to be crucial to avoid the accumulation of strain peaks caused by ipsilateral implant tips. Interprosthetic fracture management is more important in patients with reduced bone quality.

17 July 2024 in Medical Engineering & Physics
Verified
Journal Article
Open access
MHMarianne Hollensteiner
Marianne Hollensteiner
SSSabrina Sandriesser
Sabrina Sandriesser
JLJessica Libert
Jessica Libert
LSLily Spitzer-Vanech
Lily Spitzer-Vanech
DBDirk Baumeister
Dirk Baumeister
PAPeter Augat
Peter Augat
In addition to human donor bones, bone models made of synthetic materials are the gold standard substitutes for biomechanical testing of osteosyntheses. However, commercially available artificial bone models are not able to adequately reproduce the mechanical properties of human bone, especially not human osteoporotic bone. To overcome this issue, new types of polyurethane-based synthetic osteoporotic bone models have been developed. Its base materials for the cancellous bone portion and for the cortical portion have already been morphologically and mechanically validated against human bone. Thus, the aim of this study was to combine the two validated base materials for the two bone components to produce femur models with real human geometry, one with a hollow intramedullary canal and one with an intramedullary canal filled with synthetic cancellous bone, and mechanically validate them in comparison to fresh frozen human bone. These custom-made synthetic bone models were fabricated from a computer-tomography data set in a 2-step casting process to achieve not only the real geometry but also realistic cortical thicknesses of the femur. The synthetic bones were tested for axial compression, four-point bending in two planes, and torsion and validated against human osteoporotic bone. The results showed that the mechanical properties of the polyurethane-based synthetic bone models with hollow intramedullary canals are in the range of those of the human osteoporotic femur. Both, the femur models with the hollow and spongy-bone-filled intramedullary canal, showed no substantial differences in bending stiffness and axial compression stiffness compared to human osteoporotic bone. Torsional stiffnesses were slightly higher but within the range of human osteoporotic femurs. Concluding, this study shows that the innovative polyurethane-based femur models are comparable to human bones in terms of bending, axial compression, and torsional stiffness.

21 June 2021 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
MMMischa Mühling
Mischa Mühling
MWM. Winkler
M. Winkler
PAP. Augat
P. Augat
The amount of interfragmentary movement has been identified as a crucial factor for successful fracture healing. The aim of our study was to combine finite element analysis with a rigid body assumption to efficiently predict interfragmentary movement in fixed tibial fractures. The interfragmentary movement in a transverse tibial shaft fracture (AO/OTA type 42-A3) fixed with a locked plating construct was simulated using finite element analysis. In order to assess the contribution of the components on the resulting interfragmentary movement, the tibia, screws and embedding was either simulated deformable or as rigid body. The rigid and the deformable model accurately predicted the interfragmentary movement (R2 = 0.99). The axial movement ranged between 0.1 mm and 1.3 mm and shear movements were between 0.2 mm and 0.5 mm. Differences between the two models were smaller than 73 μm (axial) and 46 μm (shear). The rigid body assumption reduced computation time and memory usage by up to 61% and 97%, respectively.

11 July 2024 in Journal of Biomechanics
Verified
Journal Article
Open access
MMMischa Mühling
Mischa Mühling
SSS. Sandriesser
S. Sandriesser
SDS. Dendorfer
S. Dendorfer
PAP. Augat
P. Augat
The success of surgical treatment for fractures hinges on various factors, notably accurate surgical indication. The process of developing and certifying a new osteosynthesis device is a lengthy and costly process that requires multiple cycles of review and validation. Current methods, however, often rely on predecessor standards rather than physiological loads in specific anatomical locations. This study aimed to determine actual loads experienced by an osteosynthesis plate, exemplified by a standard locking plate for the femoral shaft, utilizing finite elements analysis (FEA) and to obtain the bending moments for implant development standard tests. A protocol was developed, involving the creation and validation of a fractured femur model fixed with a locking plate, mechanical testing, and FEA. The model 's validation demonstrated exceptional accuracy in predicting deformations, and the FEA revealed peak stresses in the fracture bridging zone. Results of a parametric analysis indicate that larger fracture gaps significantly impact implant mechanical behavior, potentially compromising stability. This study underscores the critical need for realistic physiological conditions in implant evaluations, providing an innovative translational approach to identify internal loads and optimize implant designs. In conclusion, this research contributes to enhancing the understanding of implant performance under physiological conditions, promoting improved designs and evaluations in fracture treatments.