jianan li

Dr. jianan li

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
HWHE WANG
HE WANG
JLjianan li
jianan li
BMBenjamin Edward McDonald
Benjamin Edward McDonald
TFTodd R. Farrell
Todd R. Farrell
XHXinming Huang
Xinming Huang
ECEdward Clancy
Edward Clancy
Wireless wearable sensor systems for biomedical signal acquisition have developed rapidly in recent years. Multiple sensors are often deployed for monitoring common bioelectric signals, such as EEG (electroencephalogram), ECG (electrocardiogram), and EMG (electromyogram). Compared with ZigBee and low-power Wi-Fi, Bluetooth Low Energy (BLE) can be a more suitable wireless protocol for such systems. However, current time synchronization methods for BLE multi-channel systems, via either BLE beacon transmissions or additional hardware, cannot satisfy the requirements of high throughput with low latency, transferability between commercial devices, and low energy consumption. We developed a time synchronization and simple data alignment (SDA) algorithm, which was implemented in the BLE application layer without the need for additional hardware. We further developed a linear interpolation data alignment (LIDA) algorithm to improve upon SDA. We tested our algorithms using sinusoidal input signals at different frequencies (10 to 210 Hz in increments of 20 Hz—frequencies spanning much of the relevant range of EEG, ECG, and EMG signals) on Texas Instruments (TI) CC26XX family devices, with two peripheral nodes communicating with one central node. The analysis was performed offline. The lowest average (±standard deviation) absolute time alignment error between the two peripheral nodes achieved by the SDA algorithm was 384.3 ± 386.5 μs, while that of the LIDA algorithm was 189.9 ± 204.7 μs. For all sinusoidal frequencies tested, the performance of LIDA was always statistically better than that of SDA. These average alignment errors were quite low—well below one sample period for commonly acquired bioelectric signals.

13 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JLjianan li
jianan li
EQEric Quintin
Eric Quintin
HWHE WANG
HE WANG
BMBenjamin Edward McDonald
Benjamin Edward McDonald
TFTodd R. Farrell
Todd R. Farrell
ECEdward Clancy
Edward Clancy
Wearable wireless biomedical sensors have emerged as a rapidly growing research field. For many biomedical signals, multiple sensors distributed about the body without local wired connections are required. However, designing multisite systems at low cost with low latency and high precision time synchronization of acquired data is an unsolved problem. Current solutions use custom wireless protocols or extra hardware for synchronization, forming custom systems with high power consumption that prohibit migration between commercial microcontrollers. We aimed to develop a better solution. We successfully developed a low-latency, Bluetooth low energy (BLE)-based data alignment method, implemented in the BLE application layer, making it transferable between manufacturer devices. The time synchronization method was tested on two commercial BLE platforms by inputting common sinusoidal input signals (over a range of frequencies) to evaluate time alignment performance between two independent peripheral nodes. Our best time synchronization and data alignment method achieved absolute time differences of 69 ± 71 μs for a Texas Instruments (TI) platform and 477 ± 490 μs for a Nordic platform. Their 95th percentile absolute errors were more comparable—under 1.8 ms for each. Our method is transferable between commercial microcontrollers and is sufficient for many biomedical applications.

23 January 2023 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
JLjianan li
jianan li
ZZZiling Zhu
Ziling Zhu
WBWilliam J. Boyd
William J. Boyd
CMCarlos Martinez-Luna
Carlos Martinez-Luna
CDChenyun Dai
Chenyun Dai
ECEdward A. Clancy
Edward A. Clancy

13 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KRKiriaki Rajotte
Kiriaki Rajotte
AWAnson Wooding
Anson Wooding
BMBenjamin Edward McDonald
Benjamin Edward McDonald
TFTodd R. Farrell
Todd R. Farrell
JLjianan li
jianan li
ECEdward Clancy
Edward Clancy
Concomitant improvements in wireless communication and sensor technologies have increased capabilities of wearable biosensors. These improvements have not transferred to wireless prosthesis/orthosis controllers, in part due to strict latency and power consumption requirements. We used a Bluetooth Low Energy 5.3 (BLE) network to study the influence of the connection interval (10–100 ms) and event length (2500–7500 μs), ranges appropriate for real-time myoelectric prosthesis/orthosis control on the maximum network size, power consumption, and latency. The number of connections increased from 4 to 12 as the connection interval increased from 10 to 50 ms (event length of 2500 μs). For connection intervals ≤50 ms, the number of connections reduced by ≥50% with the increasing event length. At a connection interval of 100 ms, little change was observed in the number of connections vs. event length. Across event lengths, increasing the connection interval from 10 to 100 ms decreased the average power consumed by approximately 16%. Latency measurements showed that an average of one connection interval (maximum of just over two) elapses between the application of the signal at the peripheral node ADC input and its detection on the central node. Overall, reducing the latency using shorter connection intervals reduces the maximum number of connections and increases power consumption.