Typical electromyogram (EMG) processors estimate EMG signal standard deviation (EMGs) via moving average root mean square (RMS) or mean absolute value (MAV) filters, whose outputs are used in force estimation, prosthesis/orthosis control, etc. In the inevitable presence of additive measurement noise, some processors subtract the noise standard deviation from EMG RMS (or MAV). Others compute a root difference of squares (RDS)—subtract the noise variance from the square of EMG RMS (or MAV), all followed by taking the square root. Herein, we model EMG as an amplitude-modulated random process in additive measurement noise. Assuming a Gaussian (or, separately, Laplacian) distribution, we derive analytically that the maximum likelihood estimate of EMGs requires RDS processing. Whenever that subtraction would provide a negative-valued result, we show that EMGs should be set to zero. Our theoretical models further show that during rest, approximately 50% of EMGs estimates are non-zero. This result is problematic when EMGs is used for real-time control, explaining the common use of additional thresholding. We tested our model results experimentally using biceps and triceps EMG from 64 subjects. Experimental results closely followed the Gaussian model. We conclude that EMG processors should use RDS processing and not noise standard deviation subtraction.
To facilitate the broader use of EMG signal whitening, we studied four whitening procedures of various complexities, as well as the roles of sampling rate and noise correction. We separately analyzed force-varying and constant-force contractions from 64 subjects who completed constant-posture tasks about the elbow over a range of forces from 0% to 50% maximum voluntary contraction (MVC). From the constant-force tasks, we found that noise correction via the root difference of squares (RDS) method consistently reduced EMG recording noise, often by a factor of 5–10. All other primary results were from the force-varying contractions. Sampling at 4096 Hz provided small and statistically significant improvements over sampling at 2048 Hz (~3%), which, in turn, provided small improvements over sampling at 1024 Hz (~4%). In comparing equivalent processing variants at a sampling rate of 4096 Hz, whitening filters calibrated to the EMG spectrum of each subject generally performed best (4.74% MVC EMG-force error), followed by one universal whitening filter for all subjects (4.83% MVC error), followed by a high-pass filter whitening method (4.89% MVC error) and then a first difference whitening filter (4.91% MVC error)—but none of these statistically differed. Each did significantly improve from EMG-force error without whitening (5.55% MVC). The first difference is an excellent whitening option over this range of contraction forces since no calibration or algorithm decisions are required.
1 January 2026 in IEEE Journal of Biomedical and Health Informatics
ECG is an essential diagnostic tool that offers important insight into a person's cardiac and general health. The rise of intelligent wearable devices has opened a new avenue for clinicians and individuals to capture long term ECG data-albeit with fewer leads than the 12 leads that are typically used clinically, which can be vital for identifying and addressing health concerns. In this work, a multi-task convolutional neural network (CNN) classifier was used to study the influence of various combinations of ECG leads in interpretation of 71 cardiac statements spanning cardiac diagnostics, form, and rhythm. Results of this analysis suggest that the subset of limb leads I and II and chest leads V1, V3, and V6 can be used to identify several cardiac statements without loss of performance (average macro AUC of 0.903) when compared to a model trained using all 12- leads (average macro AUC of 0.905; p = 1). A hybrid CNNLSTM (long short-term memory) model was developed to reconstruct the missing chest leads. The highest performing lead reconstructor achieved an average R2 score of 0.835 when reconstructing three chest leads. This architecture was proposed as the foundation for a wearable system that could record a limited number of ECG leads while also providing a 12-lead ECG for clinical applications.
Concomitant improvements in wireless communication and sensor technologies have increased capabilities of wearable biosensors. These improvements have not transferred to wireless prosthesis/orthosis controllers, in part due to strict latency and power consumption requirements. We used a Bluetooth Low Energy 5.3 (BLE) network to study the influence of the connection interval (10–100 ms) and event length (2500–7500 μs), ranges appropriate for real-time myoelectric prosthesis/orthosis control on the maximum network size, power consumption, and latency. The number of connections increased from 4 to 12 as the connection interval increased from 10 to 50 ms (event length of 2500 μs). For connection intervals ≤50 ms, the number of connections reduced by ≥50% with the increasing event length. At a connection interval of 100 ms, little change was observed in the number of connections vs. event length. Across event lengths, increasing the connection interval from 10 to 100 ms decreased the average power consumed by approximately 16%. Latency measurements showed that an average of one connection interval (maximum of just over two) elapses between the application of the signal at the peripheral node ADC input and its detection on the central node. Overall, reducing the latency using shorter connection intervals reduces the maximum number of connections and increases power consumption.