Laurent Pecastaing

Prof. Dr. Laurent Pecastaing

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2018 in IEEE Transactions on Plasma Science
Verified
Journal Article
Open access
Bucur-Mircea NovacBucur-Mircea Novac
Bucur-Mircea Novac
RXRenzhen Xiao
Renzhen Xiao
THTom Huiskamp
Tom Huiskamp
LPLaurent Pecastaing
Laurent Pecastaing
MWMeng Wang
Meng Wang
MRMarc Rivaletto
Marc Rivaletto
This paper introduces the work undertaken to reliably use off-the-shelf differentiating voltage probes attached to coaxial transmission lines. The results obtained prove that indeed such probes are a valid and simple instrument for measuring nanosecond and subnanosecond voltage impulses. As a bonus, this paper also highlighted an important challenging phenomenon that appears whenever an attempt is made to measure fast voltage impulses with a differentiating probe positioned too close to the closing switch of a pulse forming line generator.

30 June 2023 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
MDMawuena R. Degnon
Mawuena R. Degnon
AGAnton I. Gusev
Anton I. Gusev
AFAntoine De FERRON
Antoine De FERRON
LPLaurent Pecastaing
Laurent Pecastaing
ABAleksandr Baranov
Aleksandr Baranov
Bucur-Mircea NovacBucur-Mircea Novac
Bucur-Mircea Novac
This article is devoted to saturable pulse transformers (SPTs), combining the functions of a pulse transformer and a magnetic switch. Two nanocrystalline magnetic cores are investigated in the SPT of an inductive energy storage (IES) pulsed power system based on a semiconductor opening switch (SOS). The first magnetic core has a square hysteresis loop (Br/Bsat $>$ 90%), while the second core has a flat hysteresis loop (Br/Bsat $\sim$ 4%). A test bench with an initially stored energy of 10 J is developed. The circuit design is discussed, and the magnetic materials are compared. Based on the features of the hysteresis loops, two nanosecond high-voltage (HV) SOS generators are tested, with the output voltage adjusted by tuning the input voltage and controlling the bias magnetic field. The influence of the optimal core saturation on the operation of the SOS diode is studied. An adjustable output voltage impulse of more than 200 kV amplitude with a 16 ns rise time is demonstrated on a 1 $\text{k}\Omega$ resistive load.

13 July 2022 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
ILIvan Lavrinovich
Ivan Lavrinovich
AGAnton I. Gusev
Anton I. Gusev
SBSimon Bland
Simon Bland
AFAntoine De FERRON
Antoine De FERRON
LPLaurent Pecastaing
Laurent Pecastaing
Bucur-Mircea NovacBucur-Mircea Novac
Bucur-Mircea Novac
Impact-ionization wave triggering of a thyristor enables it to switch significantly higher currents with much faster rise times ( $\text{d}I / \text{d}t$ ) than through conventional triggering; indeed tests on commercial components demonstrate that both current and $\text{d}I / \text{d}t$ can be increased an order of magnitude over their specified datasheet values by utilizing impact ionization. However, creating an impact ionization wave places stringent requirements on the generator used to trigger the thyristor—particularly the trigger pulse must have a voltage rise rate ( $\text{d}V / \text{d}t$ ) of more than 1 kV/ns and an amplitude over twice the thyristors static breakdown voltage. Given the capacitance of a thyristor is relatively large, often hundreds of pF, this is difficult to achieve with many common triggering methods. In this study, we present a bespoke, cost-effective, trigger generator that has been developed based on spiral/vector inversion techniques coupled to an optimized sharpening circuit. Using this generator, both a 2-kV single thyristor and a 4-kV stack of two thyristors in series were triggered in the impact-ionization mode. The thyristors had a wafer diameter of 32 mm and capacitances of 370 pF. With a single thyristor 100 shots were performed with it switching a peak current of 1.25 kA and an associated $\text{d}I / \text{d}t$ of 12 kA/ $\mu \text{s}$ . With two thyristors, peak currents of 2.6 kA and with $\text{d}I / \text{d}t$ of 25 kA/ $\mu \text{s}$ were achieved. In all experiments no degradation of the semiconductor structure was observed. The work opens the way for developing very powerful, but still compact, solid-state trigger generators and larger pulsers for a wide range of pulsed power applications.

22 December 2017 in IEEE Transactions on Plasma Science
Verified
Journal Article
Open access
LPLaurent Pecastaing
Laurent Pecastaing
MRMarc Rivaletto
Marc Rivaletto
AFAntoine De FERRON
Antoine De FERRON
RPRomain Pecquois
Romain Pecquois
Bucur-Mircea NovacBucur-Mircea Novac
Bucur-Mircea Novac
The generation of high-power electromagnetic waves is one of the major applications in the field of high-intensity pulsed power. The conventional structure of a pulsed power generator contains a primary energy source and a load separated by a power-amplification system. The latter performs time compression of the slow input energy pulse and delivers a high-intensity power output to the load. Usually, either a Marx generator or a Tesla transformer is used as a power amplifier. In the present case, a system termed “module oscillant utilisant une nouvelle architecture” (MOUNA) uses an innovative and very compact resonant pulsed transformer to drive a dipole antenna. This paper describes the ultracompact multiprimary winding pulsed transformer developed in common by the Université de Pau and Hi Pulse Company that can generate voltage pulses of up to 0.6 MV, with a rise time of less than 270 ns. The transformer design has four primary windings, with two secondary windings in parallel, and a Metglas 2605SA1 amorphous iron magnetic core with an innovative biconic geometry used to optimize the leakage inductance. The overall unit has a weight of 6 kg and a volume of only 3.4 L, and this paper presents in detail its design procedure, with each of the main characteristics being separately analyzed. In particular, simple but accurate analytical calculations of both the leakage inductance and the stray capacitance between the primary and secondary windings are presented and successfully compared with CST-based results. Phenomena such as the core losses and saturation induction are also analyzed. The resonant power-amplifier output characteristics are experimentally studied when attached to a compact capacitive load, coupled to a capacitive voltage probe developed jointly with Loughborough University. Finally, an LTspice-based model of the power amplifier is introduced and its predictions are compared with results obtained from a thorough experimental study.

10 November 2020 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
NINjomza Ibrahimi
Njomza Ibrahimi
LVLeslie Vallet
Leslie Vallet
FAFranck André
Franck André
LALaurent Ariztia
Laurent Ariztia
MRMarc Rivaletto
Marc Rivaletto
LPLaurent Pecastaing
Laurent Pecastaing
This article presents an experimental arrangement which, using 3-D numerical modeling, aims to study biomedical effects using subnanosecond pulsed electric fields (PEFs). As part of a major effort into developing contactless technology, the final aim of this study is to determine conditions of the applied PEFs (number of pulses, strength, pulse repetition frequency) able to produce electropermeabilization. The arrangement uses a pulsed power generator producing voltage impulses with an amplitude of up to 20 kV on a 50-Ω matched load, with a rise time of 100 ps and a duration of 600 ps. During the preliminary study reported here, samples containing E. Coli were exposed to PEFs in a 4-mm standard electroporation cuvette, allowing the application of a peak electric field strength of up to 60 kV/cm. The studies were facilitated by detailed 3-D electromagnetic modeling of the electric field distribution generated by voltage impulses inside the system. Due to the nature of tests, the numerical analysis played an essential role in the interpretation of results. Preliminary biological results reported in this study are very encouraging, showing that trains of 5000 to 50,000 pulses applied at a pulsed repetition frequency of 200 Hz (maximum PRF) can efficiently induce E. Coli electropermeabilization.

30 March 2023 in Foods
Verified
Journal Article
Open access
PDF file
CMColin McReynolds
Colin McReynolds
Amandine AdrienAmandine Adrien
Amandine Adrien
AFAntoine De FERRON
Antoine De FERRON
NBNadia Boussetta
Nadia Boussetta
Nabil GrimiNabil Grimi
Nabil Grimi
Susana FernandesSusana Fernandes
Susana Fernandes
Gelidium corneum (syn. sesquipedale) is an industrially and ecologically important species of red alga used for the production of high-quality agar. However, the species is also of growing interest for the production of other valuable compounds, such as mycosporine-like amino acids (MAAs), with potential cosmeceutical and biomedical applications. Novel methods using two pulsed power techniques, high-voltage electrical discharges (HVED) and pulsed electrical fields (PEF), were evaluated for efficacy of MAA extraction. Algal suspensions were prepared at two ratios (1:20 and 1:40 w:v). Four different extraction protocols were compared: (i) high-voltage electrical discharges, (ii) pulsed electric fields, (iii) maceration at room temperature, and (iv) maceration at 50 °C. The algae were treated in three states: freshly harvested, dried, and powdered. HVED and PEF treatments were effective when performed on fresh algae, and in particular the HVED treatment resulted in yields of MAAs twenty times higher than the control: 0.81 ± 0.05 mg/gDry Weight (DW) vs. 0.037 ± 0.002 mg/gDW. This effect was not observed to the same extent when the algae were dried or powdered, although HVED remained the most selective method overall.