This paper introduces the work undertaken to reliably use off-the-shelf differentiating voltage probes attached to coaxial transmission lines. The results obtained prove that indeed such probes are a valid and simple instrument for measuring nanosecond and subnanosecond voltage impulses. As a bonus, this paper also highlighted an important challenging phenomenon that appears whenever an attempt is made to measure fast voltage impulses with a differentiating probe positioned too close to the closing switch of a pulse forming line generator.
30 June 2023 in IEEE Transactions on Plasma Science
This article is devoted to saturable pulse transformers (SPTs), combining the functions of a pulse transformer and a magnetic switch. Two nanocrystalline magnetic cores are investigated in the SPT of an inductive energy storage (IES) pulsed power system based on a semiconductor opening switch (SOS). The first magnetic core has a square hysteresis loop (Br/Bsat $>$ 90%), while the second core has a flat hysteresis loop (Br/Bsat $\sim$ 4%). A test bench with an initially stored energy of 10 J is developed. The circuit design is discussed, and the magnetic materials are compared. Based on the features of the hysteresis loops, two nanosecond high-voltage (HV) SOS generators are tested, with the output voltage adjusted by tuning the input voltage and controlling the bias magnetic field. The influence of the optimal core saturation on the operation of the SOS diode is studied. An adjustable output voltage impulse of more than 200 kV amplitude with a 16 ns rise time is demonstrated on a 1 $\text{k}\Omega$ resistive load.
10 November 2020 in IEEE Transactions on Plasma Science
This article presents an experimental arrangement which, using 3-D numerical modeling, aims to study biomedical effects using subnanosecond pulsed electric fields (PEFs). As part of a major effort into developing contactless technology, the final aim of this study is to determine conditions of the applied PEFs (number of pulses, strength, pulse repetition frequency) able to produce electropermeabilization. The arrangement uses a pulsed power generator producing voltage impulses with an amplitude of up to 20 kV on a 50-Ω matched load, with a rise time of 100 ps and a duration of 600 ps. During the preliminary study reported here, samples containing E. Coli were exposed to PEFs in a 4-mm standard electroporation cuvette, allowing the application of a peak electric field strength of up to 60 kV/cm. The studies were facilitated by detailed 3-D electromagnetic modeling of the electric field distribution generated by voltage impulses inside the system. Due to the nature of tests, the numerical analysis played an essential role in the interpretation of results. Preliminary biological results reported in this study are very encouraging, showing that trains of 5000 to 50,000 pulses applied at a pulsed repetition frequency of 200 Hz (maximum PRF) can efficiently induce E. Coli electropermeabilization.
22 December 2017 in IEEE Transactions on Plasma Science
The generation of high-power electromagnetic waves is one of the major applications in the field of high-intensity pulsed power. The conventional structure of a pulsed power generator contains a primary energy source and a load separated by a power-amplification system. The latter performs time compression of the slow input energy pulse and delivers a high-intensity power output to the load. Usually, either a Marx generator or a Tesla transformer is used as a power amplifier. In the present case, a system termed “module oscillant utilisant une nouvelle architecture” (MOUNA) uses an innovative and very compact resonant pulsed transformer to drive a dipole antenna. This paper describes the ultracompact multiprimary winding pulsed transformer developed in common by the Université de Pau and Hi Pulse Company that can generate voltage pulses of up to 0.6 MV, with a rise time of less than 270 ns. The transformer design has four primary windings, with two secondary windings in parallel, and a Metglas 2605SA1 amorphous iron magnetic core with an innovative biconic geometry used to optimize the leakage inductance. The overall unit has a weight of 6 kg and a volume of only 3.4 L, and this paper presents in detail its design procedure, with each of the main characteristics being separately analyzed. In particular, simple but accurate analytical calculations of both the leakage inductance and the stray capacitance between the primary and secondary windings are presented and successfully compared with CST-based results. Phenomena such as the core losses and saturation induction are also analyzed. The resonant power-amplifier output characteristics are experimentally studied when attached to a compact capacitive load, coupled to a capacitive voltage probe developed jointly with Loughborough University. Finally, an LTspice-based model of the power amplifier is introduced and its predictions are compared with results obtained from a thorough experimental study.
13 July 2022 in IEEE Transactions on Plasma Science
Impact-ionization wave triggering of a thyristor enables it to switch significantly higher currents with much faster rise times ( $\text{d}I / \text{d}t$ ) than through conventional triggering; indeed tests on commercial components demonstrate that both current and $\text{d}I / \text{d}t$ can be increased an order of magnitude over their specified datasheet values by utilizing impact ionization. However, creating an impact ionization wave places stringent requirements on the generator used to trigger the thyristor—particularly the trigger pulse must have a voltage rise rate ( $\text{d}V / \text{d}t$ ) of more than 1 kV/ns and an amplitude over twice the thyristors static breakdown voltage. Given the capacitance of a thyristor is relatively large, often hundreds of pF, this is difficult to achieve with many common triggering methods. In this study, we present a bespoke, cost-effective, trigger generator that has been developed based on spiral/vector inversion techniques coupled to an optimized sharpening circuit. Using this generator, both a 2-kV single thyristor and a 4-kV stack of two thyristors in series were triggered in the impact-ionization mode. The thyristors had a wafer diameter of 32 mm and capacitances of 370 pF. With a single thyristor 100 shots were performed with it switching a peak current of 1.25 kA and an associated $\text{d}I / \text{d}t$ of 12 kA/ $\mu \text{s}$ . With two thyristors, peak currents of 2.6 kA and with $\text{d}I / \text{d}t$ of 25 kA/ $\mu \text{s}$ were achieved. In all experiments no degradation of the semiconductor structure was observed. The work opens the way for developing very powerful, but still compact, solid-state trigger generators and larger pulsers for a wide range of pulsed power applications.
7 June 2016 in IEEE Transactions on Plasma Science
A bipolar Blumlein former has been designed and successfully implemented as an extension to an existing 10-GW-Tesla-driven Blumlein pulsed power generator. The new system is capable of generating a voltage impulse with a peak-to-peak value reaching 650 kV and having a high-frequency limit of the bandwidth well in excess of 1 GHz. Constructional details are provided, together with experimental results and analysis using the 3-D software modeling of the bipolar former that provides the results in good agreement with experimental data.