In the early stages of developing wave energy converter (WEC) projects, a quantitative assessment of component failure consequence costs is essential. The WEC types, deployment site features, and accessibility should all be carefully considered. This study introduces an operation and maintenance failure consequence cost (O&M-FC) model, distinct from conventional O&M models. The model is illustrated with case studies at three energetic Atlantic sites, each of which considers two types of generic floating WECs: a 300 kW point absorber (PA) with a hydraulic power-take-off (PTO) and a 1000 kW oscillating water column (OWC) with an air-wells-turbine PTO. This study compares 39 failure modes for PA and 27 for OWC in terms of direct repair costs and indirect lost production costs, examining the impact of location accessibility, capacity factors, and the mean annual energy production. The discussion revolves around the sensitive parameters. Recommendations for failure mitigations are presented, and the impact of planned maintenance (PM) during the operational phase is examined for 20 MW PA and OWC WEC projects. For a given WEC type, the method thoroughly evaluates how the location affects performance metrics. It offers a decision-making tool for determining optimal PM intervals to meet targets such as O&M costs, operating profit, or availability.
This paper has developed an operation and maintenance (O&M) model for projected 20 MW tidal stream farm case studies at two sites in the northeast Atlantic in France and at EMEC’s Fall of Warness site in the UK. The annual energy production, number of incidents, and downtimes of the farms for corrective and planned (preventive) maintenance strategies are estimated using Monte Carlo simulations that vary weather windows, repair vessel availabilities, and mean annual failure rates modelled by Weibull distributions. The trade-offs between the mean annual failure rates, time availability, O&M costs, and energy income minus the variable O&M costs were analysed. For all scenarios, a 5-year planned maintenance strategy could considerably decrease the mean annual failure rates by 37% at both sites and increase the net energy income. Based on a detailed sensitivity analysis, the study has suggested a simple decision-making method that examines how the variation in the mean annual failure rate and changes in spare-part costs would reduce the effectiveness of a preventive maintenance strategy. This work provides insights into the most important parameters that affect the O&M cost of tidal stream turbines and their effect on tidal energy management. The output of the study will contribute to decision-making concerning maintenance strategies.
Marine renewable energy (MRE) development will be crucial to achieve worldwide energy decarbonization. In Europe, 1 GW and 40 GW of ocean energy are set to be developed by 2030 and 2050, respectively. Support is essential if wave and tidal stream arrays are to become more economically viable than they currently are. Four recently developed open-access software tools are used in this study to investigate the critical and expensive elements of potential demonstration and commercial scale tidal projects. The tools have been designed and built to assist users with array configurations, foundation and mooring (F&M) design, operation and maintenance (O&M) strategies, and techno-economic analysis. Demonstration of their use is performed in this study to model scenarios for 2 MW, 10 MW, 40 MW, and 100 MW tidal energy projects employing typical 500 kW fixed and 2 MW floating turbines at the West Anglesey Tidal Demonstration Zone in the Irish Sea. The following metrics are examined: the power output and wake losses of staggered and line configurations; the design and costs of simple gravity-based foundations, gravity-based anchors and the four-chain catenary mooring system of a single turbine; the mean O&M costs and farm availability over the project life; and the breakdown of levelized cost of energy (LCoE) for all eight scenarios to ultimately reveal minimum values of 173 EUR/MWh and 147 EUR/MWh for fixed and floating tidal energy technologies, respectively. The thorough analysis facilitated within these four tools to forecast realistic situations in a specific location can help users design a tidal energy project for an area with considerable potential for commercial scale projects, and thus assist the ocean energy community in promoting and nurturing the sector in the years and decades ahead.
30 April 2018 in The Open Waste Management Journal
Introduction: In rural developing countries with a traditional manure management, animal manure is a value-added agricultural commodity being utilized as a source of fuel and plant nutrients. The sustainable environmental management of this resource has to consider the whole upstream and downstream activities of current management systems. Methods & Materials: In line with this requirement, this study has integrated the Intergovernmental Panel on Climate Change (IPCC) method on manure managements into the life-cycle assessment of two different manure management systems: the traditional system without biogas production and the alternative system with biogas production. Special attention is given to compare the GHG emissions as well as Nitrogen (N), Phosphorous (P), and Potassium (K) Fertilizing Nutrients (NPK) from the two systems. Results: The great advantage of manure conversion to biogas is mainly due to the avoided wood (18 kg/animal.yr), crop-residues (12 kg/ animal.yr) and dung (8 kg/ animal.yr) used as cooking fuels in the region. If methane leakage is over 38% then this will offset the GHG emission reduction of manure-to-biogas system.