Mansour Alizadeh

Prof. Dr. Mansour Alizadeh

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2018 in Journal of Central South University
Verified
Journal Article
Closed access
PDF file
HYHamidreza Yaghoubi
Hamidreza Yaghoubi
SMSeyed Amir Hossein Madani
Seyed Amir Hossein Madani
MAMansour Alizadeh
Mansour Alizadeh

1 December 2015 in Journal of Energy Engineering
Verified
Journal Article
Closed access
Hassan GholamiHassan Gholami
Hassan Gholami
HYHamidreza Yaghoubi
Hamidreza Yaghoubi
MAMansour Alizadeh
Mansour Alizadeh

18 May 2021 in Scientia Iranica
Verified
Journal Article
Closed access
PDF file
MGMohammad Gholami
Mohammad Gholami
MAMansour Alizadeh
Mansour Alizadeh
This paper presents the bending analysis of simply supported functionally graded (FG) size dependent beams based on modified strain gradient theory. The shear and normal deformations are considered in displacement field according to hyperbolic shear deformation theory. Governing equations and corresponding boundary conditions for FG micro beam are derived utilizing principle of minimum total potential energy. Mori–Tanaka homogenization scheme and the classical rule of mixture are used for prediction of material properties through the thickness. Effects of Winkler-Pasternak elastic foundation parameters are studied for different side to thickness ratios. Effects of different aspect ratios, elastic foundation parameters, power law gradient indexes and different loading conditions are investigated. The efficiency and accuracy of present model is demonstrated by comparing to the existing results in especial cases.

20 July 2022 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
MAMansour Alizadeh
Mansour Alizadeh
AKAtefeh Aghajani Koopaie
Atefeh Aghajani Koopaie
SJSaber Shakeri Jousheghan
Saber Shakeri Jousheghan
The purpose of this investigation was to assess the effects of changing the Nitinol stent’s geometrical characteristics on the superelastic behavior of the stent using the finite element method. Four different geometrical parameters were considered and analyzed in sixteen stents. These geometrical parameters consisted of stent length, number of stent’s meanders, inside diameter of the stent and wire diameter. Results showed that decreasing either stent length or the number of stent meanders and increasing either the inside diameter of the stent or wire diameter generally result in more sensible superelastic behavior exposure. The effect of changing stent length is independent of the inside diameter and number of the stent’s meanders. Effects of changing inside diameter and number of stent's meanders were exactly dependent together. In addition, increasing wire diameter has a great effect on the maximum force. In conclusion, the results of this study may serve as guidelines for future stent design.

13 October 2017 in Journal of Medical Engineering & Technology
Verified
Journal Article
Closed access
SRShahrokh Rahmani
Shahrokh Rahmani
AJAmin Jarrahi
Amin Jarrahi
MNMahdi Navidbakhsh
Mahdi Navidbakhsh
MAMansour Alizadeh
Mansour Alizadeh
One of the important parts of the cardiac system is aorta which is the fundamental channel and supply of oxygenated blood in the body. Diseases of the aorta represent critical cardiovascular bleakness and mortality around the world. This study aims at investigation of hemodynamic parameters in a two-dimensional axisymmetric model of three-layer grafted aorta using fluid–structure interaction (FSI). It assumes that a damaged part of aorta, which may happen as a result of some diseases like aneurysm, dissection and post-stenotic dilatation, is replaced with a biomaterial graft. Four types of grafts materials so-called Polyurethane, Silicone rubber, Polytetrafluoroethylene (PTFE) and Dacron are considered in the present study. The assumption of linear elastic and isotropic material is set for the both aorta's wall and aforementioned grafts. Blood is considered as an incompressible and Newtonian fluid. The results indicate higher displacement in Polyurethane and silicone rubber in comparison with other two. Furthermore, results reveal that blood flow velocity has slightly higher values in PTFE and Dacron grafted models compared to Polyurethane and Silicone rubber ones. Even though there are some differences in hemodynamic patterns in these grafted models, they are not considerable as much as von Mises stresses across the graft-aorta intersections are. This study shows that the types of material grafts play an important role in the amount of stresses particularly at intersections of aorta and graft.

9 May 2018 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
MAMansour Alizadeh
Mansour Alizadeh
SRShahrokh Rahmani
Shahrokh Rahmani
PTPedram Tehrani
Pedram Tehrani