Rocco Antonio Romeo

Dr. Rocco Antonio Romeo

Istituto Italiano di Tecnologia, Center for Robotics and Intelligent Systems, Via San Quirico19d, 16163 Genoa, Italy
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2019 in Science Robotics
Verified
Journal Article
Closed access
PDF file
LZLoredana Zollo
Loredana Zollo
GPGiovanni Di Pino
Giovanni Di Pino
ACAnna L. Ciancio
Anna L. Ciancio
FRFederico Ranieri
Federico Ranieri
Francesca CordellaFrancesca Cordella
Francesca Cordella
EGEugenio Guglielmelli
Eugenio Guglielmelli
Sensory output produced by a robotic hand during grasping and manipulation evoked real-time nearly natural force and slippage feedback.

14 April 2020 in IEEE Access
Verified
Journal Article
Open access
RRRocco Antonio Romeo
Rocco Antonio Romeo
LZLoredana Zollo
Loredana Zollo
The perception of slip is one of the distinctive abilities of human tactile sensing. The sense of touch allows recognizing a wide set of properties of a grasped object, such as shape, weight and dimension. Based on such properties, the applied force can be accordingly regulated avoiding slip of the grasped object. Despite the great importance of tactile sensing for humans, mechatronic hands (robotic manipulators, prosthetic hands etc.) are rarely endowed with tactile feedback. The necessity to grasp objects relying on robust slip prevention algorithms is not yet corresponded in existing artificial manipulators, which are relegated to structured environments then. Numerous approaches regarding the problem of slip detection and correction have been developed especially in the last decade, resorting to a number of sensor typologies. However, no impact on the industrial market has been achieved. This paper reviews the sensors and methods so far proposed for slip prevention in artificial tactile perception, starting from more classical techniques until the latest solutions tested on robotic systems. The strengths and weaknesses of each described technique are discussed, also in relation to the sensing technologies employed. The result is a summary exploring the whole state of art and providing a perspective towards the future research directions in the sector.

8 April 2016 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
ACAnna Lisa Ciancio
Anna Lisa Ciancio
Francesca CordellaFrancesca Cordella
Francesca Cordella
RBRoberto Barone
Roberto Barone
RRRocco Antonio Romeo
Rocco Antonio Romeo
ABAlberto Dellacasa Bellingegni
Alberto Dellacasa Bellingegni
LZLoredana Zollo
Loredana Zollo
This paper intends to provide a critical review of the literature on the technological issues on control and sensorization of hand prostheses interfacing with the Peripheral Nervous System (i.e. PNS), and their experimental validation on amputees. The study opens with an in-depth analysis of control solutions and sensorization features of research and commercially available prosthetic hands. Pros and cons of adopted technologies, signal processing techniques and motion control solutions are investigated. Special emphasis is then dedicated to the recent studies on the restoration of tactile perception in amputees through neural interfaces. The paper finally proposes a number of suggestions for designing the prosthetic system able to re-establish a bidirectional communication with the PNS and foster the prosthesis natural control.

10 August 2017 in Sensors
Verified
Journal Article
Open access
PDF file
RRRocco Antonio Romeo
Rocco Antonio Romeo
Calogero Maria OddoCalogero Maria Oddo
Calogero Maria Oddo
MCMaria Chiara Carrozza
Maria Chiara Carrozza
EGEugenio Guglielmelli
Eugenio Guglielmelli
LZLoredana Zollo
Loredana Zollo
One of the crucial actions to be performed during a grasping task is to avoid slippage. The human hand can rapidly correct applied forces and prevent a grasped object from falling, thanks to its advanced tactile sensing. The same capability is hard to reproduce in artificial systems, such as robotic or prosthetic hands, where sensory motor coordination for force and slippage control is very limited. In this paper, a novel algorithm for slippage detection is presented. Based on fast, easy-to-perform processing, the proposed algorithm generates an ON/OFF signal relating to the presence/absence of slippage. The method can be applied either on the raw output of a force sensor or to its calibrated force signal, and yields comparable results if applied to both normal or tangential components. A biomimetic fingertip that integrates piezoresistive MEMS sensors was employed for evaluating the method performance. Each sensor had four units, thus providing 16 mono-axial signals for the analysis. A mechatronic platform was used to produce relative movement between the finger and the test surfaces (tactile stimuli). Three surfaces with submillimetric periods were adopted for the method evaluation, and 10 experimental trials were performed per each surface. Results are illustrated in terms of slippage events detection and of latency between the slippage itself and its onset.

18 February 2021 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Open access
RRRocco Antonio Romeo
Rocco Antonio Romeo
Clemente LaurettiClemente Lauretti
Clemente Lauretti
CGCosimo Gentile
Cosimo Gentile
EGEugenio Guglielmelli
Eugenio Guglielmelli
LZLoredana Zollo
Loredana Zollo
Tactile sensing is fundamental for the human hand to achieve high dexterity. Most prosthetic hands are still devoid of tactile sensors, implying that the user cannot perceive external stimulation nor react in a fine manner. As a consequence, unforeseen events, e.g., slippage, are difficult to manage. This article proposes an algorithm to perform slippage detection with tactile sensors integrated into prosthetic hands. The algorithm is based on the filtering of the tactile sensor output; rectification and envelope follow the filtering. A binary signal, relating to slippage, is finally computed. An electrical circuit has been designed and built to elaborate the tactile signals. These have been embedded in a bioinspired fingertip mounted on a prosthetic hand, which has been interfaced with a robotic arm to assess the algorithm capability to identify slippage. Eight different surfaces have been employed, while three sliding velocities have been tested with a random interaction force between the fingertip and the test surfaces. Finally, experiments in a closed-loop configuration have been conducted to demonstrate the algorithm effectiveness in dynamic manipulation. Results proved the adequacy of the algorithm in terms of slippage detection and short latency between onset of slippage, actual detection and hand reaction.

1 January 2015 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
Paola SaccomandiPaola Saccomandi
Paola Saccomandi
Calogero Maria OddoCalogero Maria Oddo
Calogero Maria Oddo
LZLoredana Zollo
Loredana Zollo
Domenico FormicaDomenico Formica
Domenico Formica
RRRocco Antonio Romeo
Rocco Antonio Romeo
ESEmiliano Schena
Emiliano Schena
This work shows the development and characterization of a fiber optic tactile sensor based on Fiber Bragg Grating (FBG) technology. The sensor is a 3×3 array of FBGs encapsulated in a PDMS compliant polymer. The strain experienced by each FBG is transduced into a Bragg wavelength shift and the inverse characteristics of the sensor were computed by means of a feedforward neural network. A 21 mN RMSE error was achieved in estimating the force over the 8 N experimented load range while including all probing sites in the neural network training procedure, whereas the median force RMSE was 199 mN across the 200 instances of a Monte Carlo randomized selection of experimental sessions to evaluate the calibration under generalized probing conditions. The static metrological properties and the possibility to fabricate sensors with relatively high spatial resolution make the proposed design attractive for the sensorization of robotic hands. Furthermore, the proved MRI-compatibility of the sensor opens other application scenarios, such as the possibility to employ the array for force measurement during functional MRI-measured brain activation.