Turki Ali Alshehri

Dr. Turki Ali Alshehri


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2023 in Materials
Verified
Journal Article
Open access
PDF file
PEPassent Ellakany
Passent Ellakany
MMMarwa Madi
Marwa Madi
NANourhan Aly
Nourhan Aly
TATurki Ali Alshehri
Turki Ali Alshehri
SAShahad T. Alameer
Shahad T. Alameer
FAFahad A. Al-Harbi
Fahad A. Al-Harbi
The aim of this study was to assess the influences of different CAD/CAM ceramic compositions and thicknesses on the surface roughness and hardness of ceramic restorations. Four different ceramics were used in the current study: lithium disilicate (LD), leucite reinforced (LE), advanced lithium disilicate (ALD), and zirconia-reinforced lithium silicate (ZLS). Each group included 30 specimens subdivided into three different ceramic thicknesses (0.5, 1 and 1.5 mm thicknesses). The microhardness was measured for all the specimens using a microhardness testing machine, while the surface roughness was measured using a non-contact optical profilometer at three intervals (before toothbrushing and after toothbrushing, with and without toothpaste). Three-way and two-way ANOVA were used to determine the factors influencing the surface roughness and microhardness. There was a significant difference in the surface roughness between the studied groups for all the thicknesses. The findings showed that ALD had the lowest surface roughness, while ZLS showed the highest surface roughness. Moreover, ALD, followed by ZLS, had the highest hardness, while LD and LE had the lowest hardness values. Regarding the thicknesses, both the 0.5 and 1 mm ceramic thicknesses showed a significantly lower surface roughness than the 1.5 mm thickness, while the 1.5 mm thickness showed a significantly higher microhardness than the 0.5 mm thickness. The surface roughness and hardness were significantly affected by the ceramic composition and type of filler. It is recommended to use 1.5 mm-thick ceramic materials for the fabrication of definitive full-coverage ceramic restorations, while veneers require 0.5 mm-thick materials. ALD is a promising CAD/CAM material that can be used for the fabrication of restorations with a proper strength in both anterior and posterior regions.

8 April 2023 in Materials
Verified
Journal Article
Open access
PDF file
PEPassent Ellakany
Passent Ellakany
NANourhan Aly
Nourhan Aly
MAMaram A. AlGhamdi
Maram A. AlGhamdi
SAShahad T. Alameer
Shahad T. Alameer
TATurki Ali Alshehri
Turki Ali Alshehri
MMMarwa Madi
Marwa Madi
This study evaluated the effect of ultrasonic and manual scaling using different scaler materials on the surface topography of computer-aided designing and computer-aided manufacturing (CAD/CAM) ceramic compositions. After scaling with manual and ultrasonic scalers, the surface properties of four classes of CAD/CAM ceramic discs: lithium disilicate (IPE), leucite-reinforced (IPS), advanced lithium disilicate (CT), and zirconia-reinforced lithium silicate (CD) of 1.5 mm thickness were evaluated. Surface roughness was measured before and after treatment, and scanning electron microscopy was used to evaluate the surface topography following the performed scaling procedures. Two-way ANOVA was conducted to assess the association of the ceramic material and scaling method with the surface roughness. There was a significant difference in the surface roughness between the ceramic materials subjected to different scaling methods (p < 0.001). Post-hoc analyses revealed significant differences between all groups except for IPE and IPS where no significant differences were detected between them. CD showed the highest surface roughness values, while CT showed the lowest surface roughness values for the control specimens and after exposure to different scaling methods. Moreover, the specimens subjected to ultrasonic scaling displayed the highest roughness values, while the least surface roughness was noted with the plastic scaling method.

13 December 2022 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
AAAbdullah Aljami
Abdullah Aljami
TATurki Ali Alshehri
Turki Ali Alshehri
AAAbdulrahman Altuwaijri
Abdulrahman Altuwaijri
AAAlhanoof Aldossary
Alhanoof Aldossary
WAWejdan Mohammed Almutairi
Wejdan Mohammed Almutairi
BGBalgis Gaffar
Balgis Gaffar
Objective. To investigate parental factors that influence knowledge, use, and acceptance of fluoride varnish (FLV) application. Methods. This cross‐sectional study was conducted during December 2021. A multistage sampling technique was used to recruit parents with children aged 3 to 6 years and residing in Eastern Saudi Arabia, excluding those working in the dental field. The questionnaire consisted of four parts: demographics, knowledge, previous experience, and acceptance of FLV and was pilot‐tested and distributed online using social media. Results. A total of 623 parents responded to the survey. Only 36.9% of parents had good FLV knowledge with dentists being the main source of information. Gender, educational level, family income, being in the medical field, and source of knowledge were factors that significantly (P < 0.05) influenced parental knowledge. Only 24.6% of the parents applied fluoride varnish to their children before, of whom only 29% were satisfied with the experience. Parent’s FLV knowledge, view of dental visits, satisfaction with previous experience, perception of children’s oral health, and willingness to reapply FLV were factors that significantly (P < 0.05) influenced FLV use. Working in the medical field, perception of dental visits, and the source of knowledge were factors that significantly (P < 0.05) influenced the parent’s acceptance to apply FLV. While lack of knowledge about fluoride benefits (15%) was the main reason for parental refusal to apply FLV. Conclusions. The current study highlights the lack of knowledge and application of FLV among parents. There were more factors influencing mothers’ acceptance of FLV application compared to fathers. Age, educational level, working in the medical field, perception, and patterns of dental visits were some of the identified factors. Dentists played a major role in parental knowledge and FLV acceptance. In a country with high caries prevalence, preventive programs such as FLV education and application are crucial.

14 August 2023 in F1000Research
Verified
Journal Article
Open access
PDF file
TATurki Ali Alshehri
Turki Ali Alshehri
NANourhan M. Aly
Nourhan M. Aly
RARaand Altayyar
Raand Altayyar
DADeena Alghamdi
Deena Alghamdi
SAShahad Alotaibi
Shahad Alotaibi
PEPassent Ellakany
Passent Ellakany
Background: Dental post and core is one of the common procedures performed after endodontic treatment. The aim of this study was to radiographically assess the quality of post and core procedures performed by dental students at different education levels in addition to determining the most critical errors encountered during their clinical practice. Methods: A retrospective cross-sectional study design was conducted in the College of Dentistry, Imam Abdulrahman Bin Faisal University. A total of 550 periapical radiographs (PAs) of cemented posts were retrieved from the records of patients treated by dental students. Parameters and guidelines for assessing the quality of post treatment have been determined and statistically analyzed. A P value <0.05 was considered statistically significant. Results: The study included 502 students and most of them were females (66.5%). Data were obtained from 502 patients (62% females) with fiber posts used in 98.2% of the cases. About 50% of the posts were inserted in premolars, 62.9% in the upper arch, and 66.7% were restored with crowns as a final restoration. Regarding the quality of posts, 98.4% showed good preparation quality and 98% showed good radiographic quality. The post diameter was equal to 1/3 of the root diameter in 31.9% of the cases; post length was equal to 2/3 of root length in 5% of the cases and equal to or more than crown height in all cases (100%). Length of the remaining gutta percha (GP) was between 3–5 mm in 38.8%, and there was no gap between the post and remaining GP in 95.6% of the cases. There were no statistically significant differences between dental students at different clinical educational levels regarding the quality of post placement. Conclusions: The quality of post and core procedures performed by students showed acceptable radiographic quality and were within the recommended standards.

28 August 2024 in Cureus
Verified
Journal Article
Open access
TATurki Ali Alshehri
Turki Ali Alshehri
SAShahad T Alameer
Shahad T Alameer
AAAbdullah M Almotreb
Abdullah M Almotreb
A patient experiencing moderate to severe anxiety often skips regular check-ups, choosing to visit only when necessary. As a result, their oral health worsens. Various variables can affect anxiety such as age, gender, culture, and previous experiences. One of the most frequent oral surgical procedures is extracting the third molar, which is accompanied by severe pain, tension, and anxiety, the use of invasive equipment, and local anesthetic. A combined effect was found of four factors, including the patient, dental employees, setting, and dental procedure, which can trigger and affect dental anxiety. Both pharmacological and non- pharmacological approaches were explored; as a non-drug approach, anxiety was managed by music therapy. Acupuncture, music, audio-visual aids, and lavender oil showed an effect that helped in reducing anxiety. Patients' dental anxiety can be reduced through behavioral management such as educating the patients before the surgical procedure, relaxation strategies, biofeedback, and exposure therapy. Medications include benzodiazepines, nitrous oxide (N2O), 2 O), and midazolam. Effective treatment relies on collaboration between the patients and dentists; calm patients not only provide a manageable environment for the dental team but can also result in better treatment outcomes.

28 March 2024 in F1000Research
Verified
Journal Article
Open access
PDF file
TATurki Ali Alshehri
Turki Ali Alshehri
NANourhan M. Aly
Nourhan M. Aly
RARaand Altayyar
Raand Altayyar
DADeena Alghamdi
Deena Alghamdi
SAShahad Alotaibi
Shahad Alotaibi
PEPassent Ellakany
Passent Ellakany
Background Dental post and core is one of the common procedures performed after endodontic treatment. The aim of this study was to radiographically assess the quality of post and core procedures performed by dental students at different education levels in addition to determining the most critical errors encountered during their clinical practice. Methods A retrospective cross-sectional study design was conducted in the College of Dentistry, Imam Abdulrahman Bin Faisal University. A total of 550 periapical radiographs (PAs) of cemented posts were retrieved from the records of patients treated by dental students. Parameters and guidelines for assessing the quality of post treatment have been determined and statistically analyzed. A P value <0.05 was considered statistically significant. Results The study included 502 students and most of them were females (66.5%). Data were obtained from 502 patients (62% females) with fiber posts used in 98.2% of the cases. About 50% of the posts were inserted in premolars, 62.9% in the upper arch, and 66.7% were restored with crowns as a final restoration. Regarding the quality of posts, 98.4% showed good preparation quality and 98% showed good radiographic quality. The post diameter was equal to 1/3 of the root diameter in 31.9% of the cases; post length was equal to 2/3 of root length in 5% of the cases and equal to or more than crown height in all cases (100%). Length of the remaining gutta percha (GP) was between 3–5 mm in 38.8%, and there was no gap between the post and remaining GP in 95.6% of the cases. There were no statistically significant differences between dental students at different clinical educational levels regarding the quality of post placement. Conclusions The quality of post and core procedures performed by students showed acceptable radiographic quality and were within the recommended standards.