This study assessed the influence of CAD/CAM milling and 3D-printing fabrication methods on mechanical properties of 3-unit interim fixed dental prosthesis (IFDPs) after thermo-mechanical aging. Forty 3-unit IFDPs were fabricated on a mandibular right second premolar and second molar of a typodont cast. Samples were fabricated from the following materials; auto-polymerized polymethyl methacrylate (conventional resin), CAD/CAM PMMA (milled resin) and two different CAD/CAM 3D-printed composite resins; digital light processing Asiga (DLP AS) and stereolithography NextDent (SLA ND). Mechanical properties were compared between the studied materials using Kruskal–Wallis test, followed by multiple pairwise comparisons using Bonferroni adjusted significance. There was a significant difference in flexural strength and microhardness between the studied materials (p < 0.001), with the highest mean ± SD reported in the milled IFDPs (174.42 ± 3.39, 27.13 ± 0.52), and the lowest in the conventional IFDPs (98.02 ± 6.1, 15.77 ± 0.32). Flexural strengths differed significantly between the conventional IFDPs and all materials except DLP AS. The highest elastic modulus was recorded in the milled group, and the lowest in the SLA ND group (p = 0.02). In conclusion, superior flexural strength, elastic modulus, and hardness were reported for milled IFDPs. SLA ND printed IFDPs showed comparable mechanical properties to milled ones except for the elastic modulus.
Printing orientation is one of the printing parameters that affect the properties of three-dimensional (3D)-printed resins. Different printing orientations and directions have been suggested; however, no clear and specific orientations are recommended in the literature in terms of the printing orientation effect on the accuracy and fit of 3D-printed removable dental prostheses. This review aimed to evaluate the effect of printing orientation on the fit and accuracy of 3D-printed removable dental prostheses. The PubMed, Scopus, and Web of Science databases were searched for published articles that investigated the effect of printing orientations on the accuracy and fit of the 3D-printed denture base. Full-length English published articles were searched between January 2010 and December 2023, which examined topics related to printing orientations, building angles, 3D printing, printing technology, accuracy, dimensional changes, internal fit, marginal integrity, marginal discrepancies, trueness, precision, and adaptation. Of the ten included studies, one investigated maxillary and mandibular denture bases, seven assessed maxillary denture bases, and two evaluated mandibular bases. Different printing orientations, ranging from 0° to 315°, were explored, with a higher prevalence of 0°, 45°, and 90°. The included studies utilized stereolithography and digital light processing printing technologies. High accuracy was observed at 45°, followed by 90. Additional struts and bars on the cameo surface increased the accuracy of the 3D-printed denture base. These results shows that printing orientation has a significant effect on the accuracy of 3D-printed resin, with 45° exhibiting the highest accuracy. In addition to the support structure, the density and position can impact the accuracy.
9 July 2022 in International Journal of Biomaterials
Purpose. Investigate the effect of low nanodiamond (ND) addition and autoclave polymerization on the flexural strength, impact strength, and hardness of polymethylmethacrylate (PMMA) denture base. Methods. A total of 240 heat polymerized PMMA were fabricated with low ND concentrations of 0.1%, 0.25%, and 0.5%, and unmodified as control. The specimens were divided equally into group I: conventionally polymerized PMMA by water bath and group II: polymerized by the autoclave. The impact strength, flexural strength, and elastic modulus were tested using the Charpy-type impact-testing machine and three-point bending test, respectively. A scanning electron microscope (SEM) was used to analyze the fractured surfaces. Surface hardness was measured by a hardness tester with a Vickers diamond. The bonding and interaction between the PMMA and ND particles were analyzed by the Fourier-transform infrared (FTIR) spectroscope. ANOVA and post hoc Tukey test were used for data analysis (α = 0.05). Results. ND addition significantly increased the flexural strength of groups I and II ( , ); it was highest (128.8 MPa) at 0.25% ND concentration for group I and at 0.1% for group II. Elastic modulus increased at 0.1% ND for both groups ( , ), but the increase was statistically significant for group I only. Impact strength showed no significant change with the addition of ND in groups I and II ( , ), as well as surface hardness in group I ( ). Hardness decreased significantly with 0.25%ND in group II. Conclusion. The addition of ND at low concentration increased the elastic modulus and flexural strength of conventionally and autoclave polymerized denture base resin. Autoclave polymerization significantly increased the flexural strength, impact strength, and hardness of unmodified PMMA and hardness of 0.5% ND group.
Three-dimensionally (3D)-printed fabricated denture bases have shown inferior strength to conventional and subtractively fabricated ones. Several factors could significantly improve the strength of 3D-printed denture base resin, including the addition of nanoparticles and post-curing factors. This study evaluated the effect of TiO2 nanoparticle (TNP) addition and the post-curing time (PCT) on the flexural properties and hardness of three-dimensionally (3D)-printed denture base resins. A total of 360 specimens were fabricated, with 180 specimens from each type of resin. For evaluating the flexural properties, bar-shaped specimens measuring 64 × 10 × 3.3 mm were used, while, for the hardness testing, disc-shaped specimens measuring 15 × 2 mm were employed. The two 3D-printed resins utilized in this study were Asiga (DentaBASE) and NextDent (Vertex Dental B.V). Each resin was modified by adding TNPs at 1% and 2% concentrations, forming two groups and an additional unmodified group. Each group was divided into three subgroups according to the PCT (15, 60, and 90 min). All the specimens were subjected to artificial aging (5000 cycles), followed by testing of the flexural strength and elastic modulus using a universal testing machine, and the hardness using the Vickers hardness test. A three-way ANOVA was used for the data analysis, and a post hoc Tukey’s test was used for the pairwise comparisons (α = 0.05). Scanning electron microscopy (SEM) was used for the fracture surface analysis. The addition of the TNPs increased the flexural strength in comparison to the unmodified groups (p < 0.001), while there was no significant difference in the elastic modulus and hardness with the 1% TNP concentration. Among the TNP groups, the 2% TNP concentration significantly decreased the elastic modulus and hardness (p < 0.001). The SEM showed a homogenous distribution of the TNPs, and the more irregular fracture surface displayed ductile fractures. The PCT significantly increased the flexural strength, elastic modulus, and hardness (p < 0.001), and this increase was time-dependent. The three-way ANOVA results revealed a significant difference between the material types, TNP concentrations, and PCT interactions (p < 0.001). Both concentrations of the TNPs increased the flexural strength, while the 2% TNP concentration decreased the elastic modulus and hardness of the 3D-printed nanocomposites. The flexural strength and hardness increased as the PCT increased. The material type, TNP concentration, and PCT are important factors that affect the strength of 3D-printed nanocomposites and could improve their mechanical performance.
Salivary pH is a neglected factor that may affect the performance of removable dental prostheses (RDP). This study aimed to review literature in reference to the role of salivary pH on the performance of RDP and materials used for their fabrication. From January 1990 until December 2021, a search was done on PubMed, Scopus, and Web of Science databases using removable dental prostheses, salivary pH, PMMA, Denture base, and physical properties as keywords. Articles that met the inclusion criteria (full-length articles have investigated the effect of salivary pH on RDP materials in vitro and in vivo) were included. Out of 433 articles, 8 articles that met the inclusion criteria were included. All studies used artificial saliva with different salivary pH ranging between 3 and 14. Two articles investigated the role of salivary pH on the cytotoxicity of denture base resins and soft liner. One article studied the durability and retention of attachments, one article analyzed the performance of PEEK materials, one article researched the fatigue resistance of a denture base, one article investigated the corrosion of RPD framework cast and milled Co–Cr, one article studied the strength and clasp retention and deformation of acetal and PEEK materials, and one evaluated changes in mass and surface morphology of CAD–CAM fiber-reinforced composites for the prosthetic framework. Different salivary pH affected all included materials in this review except PEEK materials. The most adverse effect was reported with alkaline and acidic; however, the acidic showed the most deterioration effect. Salivary pH has a role in the selection of material used for RDP fabrication.
To evaluate the effect of beverages (coffee, tea, Cola-Cola, and mineral water) on the color stability of resin-based composite (RBC) materials modified with different nanoparticles (NPs). The specimens (70/beverage) were fabricated from light-cured RBCs and divided according to NPs into four groups: one control, unmodified (N0); and three experimental—ZrO2 (Zr), TiO2 (Ti), and SiO2 (Si) groups. Each experimental group was further subdivided into two subgroups according to NP concentrations: 3 wt.% and 7 wt.% (n = 10). A spectrophotometer was used to assess the color change (∆E) before and after six months of immersion. Data were analyzed and compared using one-way-ANOVA followed by Bonferroni’s post-hoc test (α = 0.05) and subsequently ∆E value conversion to National Bureau of Standards (NBS) units. The modified light-cured RBCs with ZrO2, TiO2, and SiO2 demonstrated smaller color changes after immersion in the beverages than the unmodified group (p < 0.001). Zr groups showed the lowest ΔE, followed by Ti and Si groups; a 3% concentration resulted in a lower mean ΔE than the 7% concentration. NBS findings showed that coffee and tea produced marked unacceptable color changes (NBS units were >3), and Coca-Cola resulted in noticeable color changes (NBS units between 1.5 and 3), while water produced slight color changes (NBS ≤ 1). Modification of RBCs with both concentrations of ZrO2, as well as 3% of TiO2 and SiO2, may improve its color stability. Based on NBS results, RBCs immersed in mineral water and Coca-Cola showed clinically acceptable color changes, while those immersed in coffee and tea were clinically unacceptable.
About Me
Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31441, Saudi Arabia.
Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31441, Saudi Arabia.