Umit UNVER

Dr. Umit UNVER

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2003 in International Communications in Heat and Mass Transfer
Verified
Journal Article
Closed access
OKO. Kaynakli
O. Kaynakli
UUUmit UNVER
Umit UNVER
Muhsin KılıçMuhsin Kılıç
Muhsin Kılıç

1 April 2019 in Journal of Cleaner Production
Verified
Journal Article
Closed access
UUUmit UNVER
Umit UNVER
OKOzlem Kara
Ozlem Kara

20 June 2022 in Journal of Cleaner Production
Verified
Journal Article
Closed access
SÇSelman Çağman
Selman Çağman
ESEren Soylu
Eren Soylu
UUUmit UNVER
Umit UNVER

4 August 2020 in International Journal of Sustainable Energy
Verified
Journal Article
Closed access
EKElif Kucukkaya
Elif Kucukkaya
Alper KeleşoğluAlper Keleşoğlu
Alper Keleşoğlu
HGHira Gunaydin
Hira Gunaydin
GKGULENAY ALEVAY KILIC
GULENAY ALEVAY KILIC
UUUmit UNVER
Umit UNVER
In this study, a passive rainwater harvesting system was designed. The system is planned to be installed on the roof of the building of Engineering Faculty of Yalova University. The meteorological rain data of Yalova province was analysed and the most suitable rainwater silo dimensions were determined accordingly. A suitable location for the silo was recommended considering the statics of the building. The passive rainwater harvesting system requires no additional pump power and no complex filtration systems. A rainwater delivery system is designed from the roof to the reservoirs for flushing without any additional energy consumption according to the storage location. The minimum height between the tank and the floor was determined to compensate the pressure losses along the critical length. The results of the economic analysis showed that this system can save about 8.5 tons of water/year and 2900 €/year water costs from one building.

15 October 2020 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
GKGULENAY ALEVAY KILIC
GULENAY ALEVAY KILIC
KAKübra Al
Kübra Al
EDEbubekir Dağtekin
Ebubekir Dağtekin
UUUmit UNVER
Umit UNVER
In this study, to meet the electrical load requirement of Yalova University campus, grid-connected hybrid power generation simulations, and grid-independent hybrid power generation simulations were made with the Hybrid Optimization Multiple Energy Resources program. Eight alternative scenarios have been surveyed by employing annual solar radiation and wind speeds, fuel cost parameters, and energy storage need of the campus. Photovoltaic panel/wind turbine/diesel generator/battery/converter is proposed in hybrid energy system scenarios. In the analysis, net present value, cost of energy per unit, emission values, renewable energy rates and sensitivity analysis are calculated and presented in figures and tables. The energy production using renewable energy sources at 61.6%, 65.4% and 75.2% and the systems without renewables were investigated. As a result of the study, it was determined that the emission of the case whit 0% renewable energy is 7.3 times higher than the case with 75.2% renewable energy used. It was seen that the emissions of the scenario with 75.2% renewable energy used are 1.56 times less than the scenario with 61.6% renewable energy used.

1 August 2006 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
UUUmit UNVER
Umit UNVER
Muhsin KılıçMuhsin Kılıç
Muhsin Kılıç
Cost analysis has a significant importance to obtain the optimum marketing price of the product of thermal systems to maximize the benefit and/or minimize the cost. Thus, this paper focuses on the investigation of the magnitude of the change in costs with respect to load and environmental temperature variations. To achieve the objective, a useful and simple second law based thermo-economic model with instant access to production costs is introduced and generalized. The presented exergy costing method indicates that the cost of reversible power is the theoretically minimum cost, where the reversible power is the theoretical maximum power that can be gained from a thermal system. The analysis has been applied to a combined cycle power plant, which is located in Bursa/Turkey. The effects of load and environmental temperature variations on costs are discussed and presented. Without considering the load effect, the cost of net electric power varied from 29 to 32$ MW−1 h−1, and about 40–45% of the cost of net electric power is composed of cost of irreversibility, while its 55–60% of it is the cost of reversible power. It is shown that the augmentation in the costs are not continuous with the environmental temperature decrease. In addition, there is an extremum at the temperature range between 5 and 10°C. Copyright © 2006 John Wiley & Sons, Ltd.