In this study, a passive rainwater harvesting system was designed. The system is planned to be installed on the roof of the building of Engineering Faculty of Yalova University. The meteorological rain data of Yalova province was analysed and the most suitable rainwater silo dimensions were determined accordingly. A suitable location for the silo was recommended considering the statics of the building. The passive rainwater harvesting system requires no additional pump power and no complex filtration systems. A rainwater delivery system is designed from the roof to the reservoirs for flushing without any additional energy consumption according to the storage location. The minimum height between the tank and the floor was determined to compensate the pressure losses along the critical length. The results of the economic analysis showed that this system can save about 8.5 tons of water/year and 2900 €/year water costs from one building.
15 October 2020 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
In this study, to meet the electrical load requirement of Yalova University campus, grid-connected hybrid power generation simulations, and grid-independent hybrid power generation simulations were made with the Hybrid Optimization Multiple Energy Resources program. Eight alternative scenarios have been surveyed by employing annual solar radiation and wind speeds, fuel cost parameters, and energy storage need of the campus. Photovoltaic panel/wind turbine/diesel generator/battery/converter is proposed in hybrid energy system scenarios. In the analysis, net present value, cost of energy per unit, emission values, renewable energy rates and sensitivity analysis are calculated and presented in figures and tables. The energy production using renewable energy sources at 61.6%, 65.4% and 75.2% and the systems without renewables were investigated. As a result of the study, it was determined that the emission of the case whit 0% renewable energy is 7.3 times higher than the case with 75.2% renewable energy used. It was seen that the emissions of the scenario with 75.2% renewable energy used are 1.56 times less than the scenario with 61.6% renewable energy used.
Triply periodic minimal surfaces (TPMSs) show potential as porous materials in different engineering applications. Amongst them, heat sink is the subject of this paper. The advantage of such a structure is the ability to design it based on the intended applications. In the present paper, an attempt is made to experiment with a better understanding of the performance of TPMSs in heat sink applications. The experiment was conducted for different flow rates, and two heat sink materials, aluminum and silver, were used. In addition, two fluids were used experimentally: The first was water, and the second was a mixture of water containing 0.6% aluminum nanoparticles and identified as a nanofluid. The applied heat flux was maintained constant at 30,800 W/m2. The results reveal experimentally and confirm numerically that the TPMS structure secures a uniform heat extraction in the system. The development of the boundary layer in the porous structure is reduced due to the current structure design. A higher Nusselt number is obtained when the nanofluid is used as the circulating fluid. The performance evaluation criteria in the presence of the nanofluid exceed 100.
Triply Periodic Minimal Surface (TPMS) heat exchangers have attracted significant attention for their high surface area and effective thermal performance. This study evaluates the performance of TPMS heat exchangers under turbulent flow conditions using aluminum (Al) and silver (Ag) materials with pure water and nanofluid as working fluids. The implementation of Ag TPMS structures resulted in approximately 15% enhancement in thermal performance compared to Al structures due to superior thermal conductivity. The introduction of nanofluid (0.6% volume concentration) improved overall heat transfer efficiency by 12% compared to pure water. Performance evaluation criteria (PEC) analysis demonstrated that Ag TPMS structures achieved up to 30% higher values than Al structures. Temperature homogeneity analyses revealed significant improvements, with Al TPMS structures showing a 24% reduction in temperature variation when using nanofluid, while Ag TPMS structures exhibited up to 40% better temperature uniformity. Computational fluid dynamics analyses validated the experimental findings with deviations less than 7%, confirming the model’s reliability. These results demonstrate the significant potential of TPMS structures in high-performance cooling applications and provide valuable insights for future heat exchanger designs. The enhanced efficiency of thermal management system (TMS) heat exchangers using nanofluids contributes to reduced energy consumption, supporting environmentally conscious decision-making in industrial and energy systems.
11 May 2023 in International Journal of Thermofluids