In this study, a passive rainwater harvesting system was designed. The system is planned to be installed on the roof of the building of Engineering Faculty of Yalova University. The meteorological rain data of Yalova province was analysed and the most suitable rainwater silo dimensions were determined accordingly. A suitable location for the silo was recommended considering the statics of the building. The passive rainwater harvesting system requires no additional pump power and no complex filtration systems. A rainwater delivery system is designed from the roof to the reservoirs for flushing without any additional energy consumption according to the storage location. The minimum height between the tank and the floor was determined to compensate the pressure losses along the critical length. The results of the economic analysis showed that this system can save about 8.5 tons of water/year and 2900 €/year water costs from one building.
15 May 2017 in Strojniški vestnik - Journal of Mechanical Engineering
This study presents the exergetic investigation of an automotive air conditioning (AAC) system with the refrigerant R1234yf experimentally. The air-conditioning system is based on the conventional mechanical compression refrigeration cycle. An internal heat exchanger (IHX) has been added to the system in order to provide performance enhancement. The influence of the IHX investigated at different compressor speeds and air stream temperatures. Experimental measurements were collected by using a data-acquisition system, and the results were obtained by performing exergetic analysis. The exergy destruction, exergy efficiency and the total exergy destruction per cooling capacity were calculated. The analysis results were compared with a baseline system which operates with the refrigerant R134a. Furthermore, an empirical correlation was proposed for the determination of the total exergy destruction per cooling capacity for various compressor speeds for evaluating the system performance without doing further experiments. As a result, the exergetic efficiency of the system was improved by introducing IHX to the system. Moreover, it was observed that the temperature rise in the air stream decreased the exergy efficiency and increased the total exergy destruction per cooling capacity.
This study represents an experimental and numerical investigation of the enhanced prototypes of the induction air heaters. For this purpose, flow field is enhanced in order to avoid turbulence. The air mass flow rate, outlet construction and the application of insulation of the outer surface of the heater were selected as the performance enhancing parameters. Depending on the exit construction, the new designed prototypes are named as K-2 and K-3. Experiments were performed under two groups for three various flow rates. In the first group, non-insulation situation is examined. In the second group tests, insulation is applied to the outside of windings and inlet-outlet flaps which constitute the boundary of the control volume for the prevention of heat losses. The increasing flow rate boosted the thermal efficiency by 9%. Each of insulation and enlarging exit cross section increased the thermal efficiency by 13%. It was observed that the thermal power transferred to air with the new prototypes increased about 246 W more than the previous designs. The thermal efficiencies of the K-2 and K-3 type heaters were calculated as 77.14% and 87.1%, respectively.
31 August 2022 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Fossil fuel firing heating systems will be substantially abandoned in the near future due to the zero-carbon goals. They will be replaced with heating systems that use renewable energy sources. Since the investment costs and area requirements of the renewable energy systems are high, the developments of highly efficient electric fluid heating systems have critical importance for a sustainable, environmentally friendly and clean heating. Among the electrical heating systems, induction heaters offer quite easy to use and better adaptability to most heating systems by allowing fluid heating without the necessity for contact. In this paper, a comprehensive review of the evolution of the induction fluid heaters is given by presenting the historical background. The most important milestones of induction fluid heating systems are presented. The development strategies suggested by the different papers including patents are investigated. The findings revealed that induction fluid heating systems, which reach approximately 100% thermal efficiency. These systems are introduced as follows: clean, non-emitting fluid heating system. Because of this, the study concludes that induction fluid heaters are one of the most promising alternatives to other electric heating systems in the long run.
Gas turbines are widely used in the energy production. The present the quantity of the operating machines requires a special attention for prediction of power production in the energy marketing sector. Thus, the aim of this paper is to support the sector by making the prediction of power production more computable. By using the data from an operating power plant, correlation and regression analysis are performed and linear equation obtained for calculating useful power production vs atmospheric air temperature and a novel method, the Gas Turbine Degree Day method, was developed. The method has been addressed for calculating the isolation related issues for buildings so far. But in this paper, it is utilized to predict the Theoretical Maximum Power Production of the Gas Turbines in various climates for the first time. The results indicated that the difference of annual energy production capacity between the best and the last province options was calculated to be 7500 MWh approximately.