Peter P Murmu

Dr. Peter P Murmu


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
AMAnmol Mahendra
Anmol Mahendra
PMPeter P Murmu
Peter P Murmu
SASusant Kumar Acharya
Susant Kumar Acharya
Atif IslamAtif Islam
Atif Islam
HFHolger Fiedler
Holger Fiedler
JKJohn Kennedy
John Kennedy
Magnetic sensors are key elements in many industrial, security, military, and biomedical applications. Heusler alloys are promising materials for magnetic sensor applications due to their high spin polarization and tunable magnetic properties. The dynamic field range of magnetic sensors is strongly related to the perpendicular magnetic anisotropy (PMA). By tuning the PMA, it is possible to modify the sensing direction, sensitivity and even the accuracy of the magnetic sensors. Here, we report the tuning of PMA in a Co2MnGa Heusler alloy film via argon (Ar) ion irradiation. MgO/Co2MnGa/Pd films with an initial PMA were irradiated with 30 keV 40Ar+ ions with fluences (ions·cm−2) between 1 × 1013 and 1 × 1015 Ar·cm−2, which corresponds to displacement per atom values between 0.17 and 17, estimated from Monte-Carlo-based simulations. The magneto optical and magnetization results showed that the effective anisotropy energy (Keff) decreased from ~153 kJ·m−3 for the un-irradiated film to ~14 kJ·m−3 for the 1 × 1014 Ar·cm−2 irradiated film. The reduced Keff and PMA are attributed to ion-irradiation-induced interface intermixing that decreased the interfacial anisotropy. These results demonstrate that ion irradiation is a promising technique for shaping the PMA of Co2MnGa Heusler alloy for magnetic sensor applications.

21 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Abhinay SandupatlaAbhinay Sandupatla
Abhinay Sandupatla
SASubramaniam Arulkumaran
Subramaniam Arulkumaran
KRKumud Ranjan
Kumud Ranjan
GNGeok Ng
Geok Ng
PMPeter P Murmu
Peter P Murmu
Hiroshi AmanoHiroshi Amano
Hiroshi Amano
A low voltage (−20 V) operating high-energy (5.48 MeV) α-particle detector with a high charge collection efficiency (CCE) of approximately 65% was observed from the compensated (7.7 × 1014 /cm3) metalorganic vapor phase epitaxy (MOVPE) grown 15 µm thick drift layer gallium nitride (GaN) Schottky diodes on free-standing n+-GaN substrate. The observed CCE was 30% higher than the bulk GaN (400 µm)-based Schottky barrier diodes (SBD) at −20 V. This is the first report of α–particle detection at 5.48 MeV with a high CCE at −20 V operation. In addition, the detectors also exhibited a three-times smaller variation in CCE (0.12 %/V) with a change in bias conditions from −120 V to −20 V. The dramatic reduction in CCE variation with voltage and improved CCE was a result of the reduced charge carrier density (CCD) due to the compensation by Mg in the grown drift layer (DL), which resulted in the increased depletion width (DW) of the fabricated GaN SBDs. The SBDs also reached a CCE of approximately 96.7% at −300 V.

24 July 2015 in Coatings
Verified
Journal Article
Open access
PDF file
KSKonrad Suschke
Konrad Suschke
RHRene Huebner
Rene Huebner
PMPeter P Murmu
Peter P Murmu
PGPrasanth Gupta Sridhar Gupta
Prasanth Gupta Sridhar Gupta
JFJohn Futter
John Futter
AMAndreas Markwitz
Andreas Markwitz
Diamond-like carbon (DLC) coatings were deposited with a new direct ion deposition system using a novel 360 degree ion source operating at acceleration voltage between 4 and 8 kV. Cross-sectional TEM images show that the coatings have a three layered structure which originates from changes in the deposition parameters taking into account ion source condition, ion current density, deposition angles, ion sputtering and ion source movement. Varying structural growth conditions can be achieved by tailoring the deposition parameters. The coatings show good promise for industrial use due to their high hardness, low friction and excellent adhesion to the surface of the samples.