Leon Jacobse

Dr. Leon Jacobse

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2018 in Nature Materials
Verified
Journal Article
Closed access
PDF file
LJLeon Jacobse
Leon Jacobse
YHYi-Fan Huang
Yi-Fan Huang
MKMarc T. M. Koper
Marc T. M. Koper
MRMarcel J. Rost
Marcel J. Rost

13 October 2021 in JACS Au
Verified
Journal Article
Open access
MMMariana Monteiro
Mariana Monteiro
AMAlex Mirabal
Alex Mirabal
LJLeon Jacobse
Leon Jacobse
KDKatharina Doblhoff-Dier
Katharina Doblhoff-Dier
SBScott Calabrese Barton
Scott Calabrese Barton
MKMarc T. M. Koper
Marc T. M. Koper
The electrochemical reduction of CO2 is widely studied as a sustainable alternative for the production of fuels and chemicals. The electrolyte’s bulk pH and composition play an important role in the reaction activity and selectivity and can affect the extent of the buildup of pH gradients between the electrode surface and the bulk of the electrolyte. Quantifying the local pH and how it is affected by the solution species is desirable to gain a better understanding of the CO2 reduction reaction. Local pH measurements can be realized using Scanning Electrochemical Microscopy (SECM); however, finding a pH probe that is stable and selective under CO2 reduction reaction conditions is challenging. Here, we have used our recently developed voltammetric pH sensor to perform pH measurements in the diffusion layer during CO2 reduction using SECM, with high time resolution. Using a 4-hydroxylaminothiophenol (4-HATP)/4-nitrosothiophenol (4-NSTP) functionalized gold ultramicroelectrode, we compare the local pH developed above a gold substrate in an argon atmosphere, when only hydrogen evolution is taking place, to the pH developed in a CO2 atmosphere. The pH is monitored at a fixed distance from the surface, and the sample potential is varied in time. In argon, we observe a gradual increase of pH, while a plateau region is present in CO2 atmosphere due to the formation of HCO3– buffering the reaction interface. By analyzing the diffusion layer dynamics once the sample reaction is turned “off”, we gain insightful information on the time scale of the homogeneous reactions happening in solution and on the time required for the diffusion layer to fully recover to the initial bulk concentration of species. In order to account for the effect of the presence of the SECM tip on the measured pH, we performed finite element method simulations of the fluid and reaction dynamics. The results show the significant localized diffusion hindrance caused by the tip, so that in its absence, the pH values are more acidic than when the tip is present. Nonetheless, through the simulation, we can account for this effect and estimate the real local pH values across the diffusion layer.

5 May 2015 in Analytical Chemistry
Verified
Journal Article
Closed access
CCChang-Hui Chen
Chang-Hui Chen
LJLeon Jacobse
Leon Jacobse
KMKim McKelvey
Kim McKelvey
SLStanley Lai
Stanley Lai
MKMarc T. M. Koper
Marc T. M. Koper
PUPatrick R. Unwin
Patrick R. Unwin

24 December 2019 in Analytical Chemistry
Verified
Journal Article
Open access
MMMariana Monteiro
Mariana Monteiro
LJLeon Jacobse
Leon Jacobse
TTThomas Touzalin
Thomas Touzalin
MKMarc T. M. Koper
Marc T. M. Koper
Probing pH gradients during electrochemical reactions is important to better understand reaction mechanisms and to separate the influence of pH and pH gradients from intrinsic electrolyte effects. Here, we develop a pH sensor to measure pH changes in the diffusion layer during hydrogen evolution. The probe was synthesized by functionalizing a gold ultramicroelectrode with a self-assembled monolayer of 4-nitrothiophenol (4-NTP) and further converting it to form a hydroxylaminothiophenol (4-HATP)/4-nitrosothiophenol (4-NSTP) redox couple. The pH sensing is realized by recording the tip cyclic voltammetry and monitoring the Nernstian shift of the mid-peak potential. We employ a capacitive approach technique in our home-built Scan-ning Electrochemical Microscope (SECM) setup in which an AC potential is applied to the sample and the capacitive current generated at the tip is recorded as a function of distance. This method allows for an approach of the tip to the electrode that is electrolyte-free and consequently also mediator-free. Hydrogen evolution on gold in a neutral electrolyte was studied as a model system. The pH was measured with the probe at constant distance from the electrode (ca. 75 μm) while the electrode potential was varied in time. In the non-buffered electrolyte used (0.1 M Li2SO4), even at relatively low current densities, a pH difference of three units is measured between the location of the probe and the bulk electrolyte. The time scale of the diffusion layer tran-sient is captured, due to the high time resolution that can be achieved with this probe. The sensor has high sensitivity, measur-ing differences of more than 8 pH units with a resolution better than 0.1 pH unit.

2 November 2020 in The Journal of Physical Chemistry Letters
Verified
Journal Article
Open access
MMMariana Monteiro
Mariana Monteiro
LJLeon Jacobse
Leon Jacobse
MKMarc T. M. Koper
Marc T. M. Koper
Recently, the bulk electrooxidation of CO on gold or platinum has been used to detect CO produced during CO2 reduction in neutral media. The CO bulk oxidation voltammetry may show two distinct peaks depending on the reaction conditions, which up to now have not been understood. We have used scanning electrochemical microscopy (SECM) to probe CO oxidation and pH in the diffusion layer during CO2 reduction. Our results show that the two different peaks are due to diffusion limitation by two different species, namely, CO and OH–. We find that between pH 7 and 11, CO oxidation by water and OH– gives rise to the first and second peak observed in the voltammetry, respectively. Additional rotating disc experiments showed that specifically in this pH range the current of the second peak is diffusion limited by the OH– concentration, since it is lower than the CO concentration.

15 November 2019 in ACS Central Science
Verified
Journal Article
Open access
LJLeon Jacobse
Leon Jacobse
MRMarcel J. Rost
Marcel J. Rost
MKMarc T. M. Koper
Marc T. M. Koper
Electrode degradation under oxidizing conditions is a major drawback for large-scale applications of platinum electrocatalysts. Subjecting Pt(111) to oxidation–reduction cycles is known to lead to the growth of nanoislands. We study this phenomenon using a combination of simultaneous in situ electrochemical scanning tunneling microscopy and cyclic voltammetry. Here, we present a detailed analysis of the formed islands, deriving the (evolution of the) average island growth shape. From the island shapes, we determine the densities of atomic-scale defect sites, e.g., steps and facets, which show an excellent correlation with the different voltammetric hydrogen adsorption peaks. Based on this combination of electrochemical scanning tunneling microscopy (EC-STM) and CV data, we derive a detailed atomistic picture of the nanoisland evolution during potential cycling, delivering new insights into the initial stages of platinum electrode degradation.