Josep Farré-Lladós

Dr. Josep Farré-Lladós

Universitat Politècnica de Catalunya - Barcelona Tech
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
EPEnric Perarnau
Enric Perarnau
JFJosep Farré-Lladós
Josep Farré-Lladós
Jasmina Casals-TerréJasmina Casals-Terré
Jasmina Casals-Terré
In recent years, advancements in micromachining techniques and nanomaterials have enabled the fabrication of highly sensitive devices for the detection of odorous species. Recent efforts done in the miniaturization of gas sensors have contributed to obtain increasingly compact and portable devices. Besides, the implementation of new nanomaterials in the active layer of these devices is helping to optimize their performance and increase their sensitivity close to humans’ olfactory system. Nonetheless, a common concern of general-purpose gas sensors is their lack of selectivity towards multiple analytes. In recent years, advancements in microfabrication techniques and microfluidics have contributed to create new microanalytical tools, which represent a very good alternative to conventional analytical devices and sensor-array systems for the selective detection of odors. Hence, this paper presents a general overview of the recent advancements in microfabricated gas sensors and microanalytical devices for the sensitive and selective detection of volatile organic compounds (VOCs). The working principle of these devices, design requirements, implementation techniques, and the key parameters to optimize their performance are evaluated in this paper. The authors of this work intend to show the potential of combining both solutions in the creation of highly compact, low-cost, and easy-to-deploy platforms for odor monitoring.

27 October 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
PMPouya Mehrdel
Pouya Mehrdel
SKShadi Karimi
Shadi Karimi
JFJosep Farré-Lladós
Josep Farré-Lladós
Jasmina Casals-TerréJasmina Casals-Terré
Jasmina Casals-Terré
A novel type of spiral micromixer with expansion and contraction parts is presented in order to enhance the mixing quality in the low Reynolds number regimes for point-of-care tests (POCT). Three classes of micromixers with different numbers of loops and modified geometries were studied. Numerical simulation was performed to study the flow behavior and mixing performance solving the steady-state Navier–Stokes and the convection-diffusion equations in the Reynolds range of 0.1–10.0. Comparisons between the mixers with and without expansion parts were made to illustrate the effect of disturbing the streamlines on the mixing performance. Image analysis of the mixing results from fabricated micromixers was used to verify the results of the simulations. Since the proposed mixer provides up to 92% of homogeneity at Re 1.0, generating 442 Pa of pressure drop, this mixer makes a suitable candidate for research in the POCT field.

3 November 2022 in Macromolecular Materials and Engineering
Verified
Journal Article
Open access
EPEnric Perarnau
Enric Perarnau
Jasmina Casals-TerréJasmina Casals-Terré
Jasmina Casals-Terré
JMJoan Antoni López Martínez
Joan Antoni López Martínez
JFJosep Farré-Lladós
Josep Farré-Lladós
Polymeric materials are widely employed for monitoring volatile organic compounds (VOCs). Compared to other sensitive materials, polymers can provide a certain degree of selectivity, based on their chemical affinity with organic solvents. The addition of conductive nanoparticles within the polymer layer is a common practice in recent years to improve the sensitivity of these materials. However, it is still unclear the effect that the nanoparticles have on the selectivity of the polymer membrane and vice versa. The current work proposes a methodology based on the Hansen solubility parameters, for assessing the selectivity of both pristine and hybrid polymer nanocomposites. The impedance response of thin polydimethylsiloxane (PDMS) films is compared to the response of hybrid polymer films, based on the addition of multi‐walled carbon nanotubes (MWCNTs). With the addition of just 1 wt.% of MWCNTs, fabricated sensors showcased a significant improvement in sensitivity, faster response times, as well as enhanced classification of non‐polar analytes (>22% increase) compared to single PDMS layers. The methodology proposed in this work can be employed in the future to assess and predict the selectivity of polymers in single or array‐based gas sensors, microfluidic channels, and other analytical devices for the purpose of VOCs discrimination.

21 February 2021 in Membranes
Verified
Journal Article
Open access
PDF file
GRGenís Rabost-Garcia
Genís Rabost-Garcia
JFJosep Farré-Lladós
Josep Farré-Lladós
Jasmina Casals-TerréJasmina Casals-Terré
Jasmina Casals-Terré
Skin models offer an in vitro alternative to human trials without their high costs, variability, and ethical issues. Perspiration models, in particular, have gained relevance lately due to the rise of sweat analysis and wearable technology. The predominant approach to replicate the key features of perspiration (sweat gland dimensions, sweat rates, and skin surface characteristics) is to use laser-machined membranes. Although they work effectively, they present some limitations at the time of replicating sweat gland dimensions. Alternative strategies in terms of fabrication and materials have also showed similar challenges. Additional research is necessary to implement a standardized, simple, and accurate model representing sweating for wearable sensors testing.

1 May 2021 in Food Chemistry
Verified
Journal Article
Closed access
PMPouya Mehrdel
Pouya Mehrdel
SKShadi Karimi
Shadi Karimi
JFJosep Farré-Lladós
Josep Farré-Lladós
Jasmina Casals-TerréJasmina Casals-Terré
Jasmina Casals-Terré

14 August 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
SKShadi Karimi
Shadi Karimi
JFJosep Farré-Lladós
Josep Farré-Lladós
EMEnrique Mir
Enrique Mir
GEGines Escolar
Gines Escolar
Jasmina Casals-TerréJasmina Casals-Terré
Jasmina Casals-Terré
In the case of vascular injury, a complex process (of clotting) starts, involving mainly platelets and coagulation factors. This process in healthy humans is known as hemostasis, but when it is deregulated (thrombosis), it can be the cause of important cardiovascular diseases. Nowadays, the aging of the population and unhealthy lifestyles increase the impact of thrombosis, and therefore there is a need for tools to provide a better understanding of the hemostasis mechanisms, as well as more cost-effective diagnosis and control devices. This study proposes a novel microflow chamber, with interchangeable biomimetic surfaces to evaluate global hemostasis, using reduced amounts of blood sample and reagents, and also a minimized time required to do the test. To validate the performance of this novel device, a study on the new oral anticoagulant Apixaban (APIX) has been performed and compared to previous conventional techniques. The test shows an excellent agreement, while the amount of the required sample has been reduced (only 100 µL is used), and the amount of reagent as well. An imprinted electrode embedded in the chamber in order to measure the impedance during the coagulation process. This approach distinguishes the impedance behavior of plasma poor in platelets (PPP) and plasma rich in platelets (PRP) for the first time.