This paper presents analysis, design, realization, and experimental demonstration of a bistable switch actuated dynamically utilizing mechanical resonance phenomenon. We demonstrated that if a bistable structure is driven into a resonance near one of its states, it may achieve a large enough amplitude of vibration, sufficient to switch between its stable states. Using energy analysis, we concluded that dynamic switching of bistable structures may provide significant energy advantages over conventional static-switching approaches. To confirm the results, we derived analytically the closed-form actuation conditions guaranteeing switching between the states of a bistable structure and applied these conditions to experimental devices. Micromachined prototypes of dynamically actuated bistable switches were designed, fabricated, and characterized. We demonstrated experimentally that resonant dynamic switching provides energy saving of around 60% at atmospheric pressure with proportional increase in efficiency as the pressure decreases.
30 April 2015 in Analytical and Bioanalytical Chemistry
Electrostatic parallel-plate actuators are a common way of actuating microelectromechanical systems, both statically and dynamically. In the static case, the stable actuation voltages are limited by the static pull-in condition, which indicates that the travel range is approximately limited to 1/3 of the initial actuation gap. Under dynamic actuation conditions, however, the stable voltages are reduced, whereas the travel range can be much extended. This is the case with the dynamic pull-in and the resonant pull-in conditions (RPCs). Using energy analysis, this paper extends the study of pull-in instability to the resonant case and derives the analytical RPC. This condition predicts snapping or pull-in of the structure for a given domain of dc and ac actuation voltages versus quality factor, taking into account the nonlinearities due to large amplitudes of oscillation. Experimental results are presented to validate the analytically derived RPC.
There is currently a growing need for lab-on-a-chip devices for use in clinical analysis and diagnostics, especially in the area of patient care. The first step in most blood assays is plasma extraction from whole blood. This paper presents a novel, self-driven blood plasma separation microfluidic chip, which can extract more than 0.1 μ l plasma from a single droplet of undiluted fresh human blood (∼5 μ l). This volume of blood plasma is extracted from whole blood with high purity (more than 98%) in a reasonable time frame (3 to 5 min), and without the need for any external force. This would be the first step towards the realization of a single-use, self-blood test that does not require any external force or power source to deliver and analyze a fresh whole-blood sample, in contrast to the existing time-consuming conventional blood analysis. The prototypes are manufactured in polydimethylsiloxane that has been modified with a strong nonionic surfactant (Silwet L-77) to achieve hydrophilic behavior. The main advantage of this microfluidic chip design is the clogging delay in the filtration area, which results in an increased amount of extracted plasma (0.1 μ l). Moreover, the plasma can be collected in one or more 10 μ m-deep channels to facilitate the detection and readout of multiple blood assays. This high volume of extracted plasma is achieved thanks to a novel design that combines maximum pumping efficiency without disturbing the red blood cells’ trajectory through the use of different hydrodynamic principles, such as a constriction effect and a symmetrical filtration mode. To demonstrate the microfluidic chip’s functionality, we designed and fabricated a novel hybrid microdevice that exhibits the benefits of both microfluidics and lateral flow immunochromatographic tests. The performance of the presented hybrid microdevice is validated using rapid detection of thyroid stimulating hormone within a single droplet of whole blood.
In recent years, advancements in micromachining techniques and nanomaterials have enabled the fabrication of highly sensitive devices for the detection of odorous species. Recent efforts done in the miniaturization of gas sensors have contributed to obtain increasingly compact and portable devices. Besides, the implementation of new nanomaterials in the active layer of these devices is helping to optimize their performance and increase their sensitivity close to humans’ olfactory system. Nonetheless, a common concern of general-purpose gas sensors is their lack of selectivity towards multiple analytes. In recent years, advancements in microfabrication techniques and microfluidics have contributed to create new microanalytical tools, which represent a very good alternative to conventional analytical devices and sensor-array systems for the selective detection of odors. Hence, this paper presents a general overview of the recent advancements in microfabricated gas sensors and microanalytical devices for the sensitive and selective detection of volatile organic compounds (VOCs). The working principle of these devices, design requirements, implementation techniques, and the key parameters to optimize their performance are evaluated in this paper. The authors of this work intend to show the potential of combining both solutions in the creation of highly compact, low-cost, and easy-to-deploy platforms for odor monitoring.
A novel type of spiral micromixer with expansion and contraction parts is presented in order to enhance the mixing quality in the low Reynolds number regimes for point-of-care tests (POCT). Three classes of micromixers with different numbers of loops and modified geometries were studied. Numerical simulation was performed to study the flow behavior and mixing performance solving the steady-state Navier–Stokes and the convection-diffusion equations in the Reynolds range of 0.1–10.0. Comparisons between the mixers with and without expansion parts were made to illustrate the effect of disturbing the streamlines on the mixing performance. Image analysis of the mixing results from fabricated micromixers was used to verify the results of the simulations. Since the proposed mixer provides up to 92% of homogeneity at Re 1.0, generating 442 Pa of pressure drop, this mixer makes a suitable candidate for research in the POCT field.