Pouya Mehrdel

Dr. Pouya Mehrdel

Polytechnic University of Catalunya
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
PMPouya Mehrdel
Pouya Mehrdel
SKShadi Karimi
Shadi Karimi
JFJosep Farré-Lladós
Josep Farré-Lladós
Jasmina Casals-TerréJasmina Casals-Terré
Jasmina Casals-Terré
A novel type of spiral micromixer with expansion and contraction parts is presented in order to enhance the mixing quality in the low Reynolds number regimes for point-of-care tests (POCT). Three classes of micromixers with different numbers of loops and modified geometries were studied. Numerical simulation was performed to study the flow behavior and mixing performance solving the steady-state Navier–Stokes and the convection-diffusion equations in the Reynolds range of 0.1–10.0. Comparisons between the mixers with and without expansion parts were made to illustrate the effect of disturbing the streamlines on the mixing performance. Image analysis of the mixing results from fabricated micromixers was used to verify the results of the simulations. Since the proposed mixer provides up to 92% of homogeneity at Re 1.0, generating 442 Pa of pressure drop, this mixer makes a suitable candidate for research in the POCT field.

3 September 2019 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SKShadi Karimi
Shadi Karimi
PMPouya Mehrdel
Pouya Mehrdel
JFJosep Farré-Lladós
Josep Farré-Lladós
Jasmina Casals-TerréJasmina Casals-Terré
Jasmina Casals-Terré
A passive portable microfluidic blood–plasma separator for simultaneous determination of direct and indirect ABO/Rh blood typing.

8 March 2021 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
SKShadi Karimi
Shadi Karimi
MMMohammad Mojaddam
Mohammad Mojaddam
SMSahand Majidi
Sahand Majidi
PMPouya Mehrdel
Pouya Mehrdel
JFJosep Farré-Lladós
Josep Farré-Lladós
Jasmina Casals-TerréJasmina Casals-Terré
Jasmina Casals-Terré

1 May 2021 in Food Chemistry
Verified
Journal Article
Closed access
PMPouya Mehrdel
Pouya Mehrdel
SKShadi Karimi
Shadi Karimi
JFJosep Farré-Lladós
Josep Farré-Lladós
Jasmina Casals-TerréJasmina Casals-Terré
Jasmina Casals-Terré

26 February 2020 in Biofabrication
Verified
Journal Article
Open access
PDF file
SKShadi Karimi
Shadi Karimi
PMPouya Mehrdel
Pouya Mehrdel
Jasmina Casals-TerréJasmina Casals-Terré
Jasmina Casals-Terré
JFJosep Farré-Llados
Josep Farré-Llados
Micro Electro Mechanical Systems (MEMS) and microfluidic devices have found numerous applications in the industrial sector. However, they require a fast, cost-effective and reliable manufacturing process in order to compete with conventional methods. Particularly, at the sub-micron scale, the manufacturing of devices are limited by the dimensional complexity. A proper bonding and stiction prevention of these sub-micron channels are two of the main challenges faced during the fabrication process of low aspect ratio channels. Especially, in the case of using flexible materials such as polydimethylsiloxane (PDMS). This study presents a direct laser microfabrication method of sub-micron channels using an infrared (IR) ultrashort pulse (femtosecond), capable of manufacturing extremely low aspect ratio channels. These microchannels are manufactured and tested varying their depth from 0.5 μ m to 2 μ m and width of 15, 20, 25, and 30 μ m. The roughness of each pattern was measured by an interferometric microscope. Additionally, the static contact angle of each depth was studied to evaluate the influence of femtosecond laser fabrication method on the wettability of the glass substrate. PDMS, which is a biocompatible polymer, was used to provide a watertight property to the sub-micron channels and also to assist the assembly of external microfluidic hose connections. A 750 nm depth watertight channel was built using this methodology and successfully used as a blood plasma separator (BPS). The device was able to achieve 100% pure plasma without stiction of the PDMS layer to the sub-micron channel within an adequate time. This method provides a novel manufacturing approach useful for various applications such as point-of-care devices.

11 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
PMPouya Mehrdel
Pouya Mehrdel
Hamid KhosraviHamid Khosravi
Hamid Khosravi
SKShadi Karimi
Shadi Karimi
JMJoan Antoni López Martínez
Joan Antoni López Martínez
Jasmina Casals-TerréJasmina Casals-Terré
Jasmina Casals-Terré
Microfluidic paper-based analytical devices (µPADs) are a promising technology to enable accurate and quantitative in situ assays. Paper’s inherent hydrophilicity drives the fluids without the need for external pressure sources. However, controlling the flow in the porous medium has remained a challenge. This study addresses this problem from the nature of the paper substrate and its design. A computational fluid dynamic model has been developed, which couples the characteristics of the porous media (fiber length, fiber diameter and porosity) to the fluidic performance of the diffusion-based µPAD sensor. The numerical results showed that for a given porous membrane, the diffusion, and therefore the sensor performance is affected not only by the substrate nature but also by the inlets’ orientation. Given a porous substrate, the optimum performance is achieved by the lowest inlets’ angle. A diffusion-based self-referencing colorimetric sensor was built and validated according to the design. The device is able to quantify the hydronium concentration in wines by comparison to 0.1–1.0 M tartaric acid solutions with a 41.3 mM limit of detection. This research showed that by proper adjustments even the simplest µPADs can be used in quantitative assays for agri-food applications.