Salzitsa Anastasova-Ivanova

Dr. Salzitsa Anastasova-Ivanova

Faculty of Engineering, Department of Computing, Imperial College London, UK
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
SASalzitsa Anastasova-Ivanova
Salzitsa Anastasova-Ivanova
BCBlair Crewther
Blair Crewther
PBPawel Bembnowicz
Pawel Bembnowicz
VCVincenzo Curto
Vincenzo Curto
HIHenry Md Ip
Henry Md Ip
GYGuang-Zhong Yang
Guang-Zhong Yang
In sport, exercise and healthcare settings, there is a need for continuous, non-invasive monitoring of biomarkers to assess human performance, health and wellbeing. Here we report the development of a flexible microfluidic platform with fully integrated sensing for on-body testing of human sweat. The system can simultaneously and selectively measure metabolite (e.g. lactate) and electrolytes (e.g. pH, sodium) together with temperature sensing for internal calibration. The construction of the platform is designed such that continuous flow of sweat can pass through an array of flexible microneedle type of sensors (50µm diameter) incorporated in a microfluidic channel. Potentiometric sodium ion sensors were developed using a polyvinyl chloride (PVC) functional membrane deposited on an electrochemically deposited internal layer of Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer. The pH sensing layer is based on a highly sensitive membrane of iridium oxide (IrOx). The amperometric-based lactate sensor consists of doped enzymes deposited on top of a semipermeable copolymer membrane and outer polyurethane layers. Real-time data were collected from human subjects during cycle ergometry and treadmill running. A detailed comparison of sodium, lactate and cortisol from saliva is reported, demonstrating the potential of the multi-sensing platform for tracking these outcomes. In summary, a fully integrated sensor for continuous, simultaneous and selective measurement of sweat metabolites, electrolytes and temperature was achieved using a flexible microfluidic platform. This system can also transmit information wirelessly for ease of collection and storage, with the potential for real-time data analytics.

4 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
BGBruno Gil
Bruno Gil
SASalzitsa Anastasova-Ivanova
Salzitsa Anastasova-Ivanova
GYGuang Z. Yang
Guang Z. Yang
Wearable biomedical technology has gained much support lately as devices have become more affordable to the general public and they can easily interact with mobile phones and other platforms. The feasibility and accuracy of the data generated by these devices so as to replace the standard medical methods in use today is still under scrutiny. In this paper, we present an ear-worn device to measure cardiovascular and sweat parameters during physical exercise. ECG bipolar recordings capture the electric potential around both ears, whereas sweat rate is estimated by the impedance method over one segment of tissue closer to the left ear, complemented by the measurement of the lactate and pH levels using amperiometric and potentiometric sensors, respectively. Together with head acceleration, the acquired data is sent to a mobile phone via BLE, enabling extended periods of signal recording. Results obtained by the device have shown a SNR level of 18 dB for the ECG signal recorded around the ears, a THD value of −20.46 dB for the excitation signal involved in impedance measurements, sweat conductivity of 0.08 S/m at 1 kHz and sensitivities of 50 mV/pH and 0.8 μA/mM for the pH and lactate acquisition channels, respectively. Testing of the device was performed in human subjects during indoors cycling with characteristic level changes.

1 April 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
SASalzitsa Anastasova-Ivanova
Salzitsa Anastasova-Ivanova
Panagiotis KassanosPanagiotis Kassanos
Panagiotis Kassanos
GYGuang-Zhong Yang
Guang-Zhong Yang
The measurement of Na+, K+ and H+ is essential in medicine and plays an important role in the assessment of tissue ischemia. Microfabrication, inkjet- and screen-printing can be used for solid contact ion selective electrodes (ISE) realization; these, however, can be non-standardized, costly and time consuming processes. We present the realization of ISEs on post-processed electrodes fabricated via standardized printed circuit board (PCB) manufacturing techniques. In vitro results are presented from two rigid platforms (32 ISEs) for liquid sample dip-stick measurements and two flexible platforms (6 and 32 ISEs) for post-surgical intestinal tissue monitoring, each with a common reference electrode (RE). These are combined with optimized tetrapolar bioimpedance sensors for tissue ischemia detection. Both electroless and hard gold PCB finishes are examined. Apart from the electroless rigid platform, the rest demonstrated comparable and superior performance, with the pH sensors demonstrating the greatest deviation; the flexible hard gold platform achieved a sensitivity 4.6mV/pH and 49.2mV/pH greater than the electroless flexible and rigid platforms, respectively. The best overall performance was achieved with the hard gold flexible platform with sensitivities as large as 73.4mV/pH, 56.3mV/log [Na+], and 57.4mV/log [K+] vs. custom REs on the same substrate. Simultaneous measurement of target analytes is demonstrated with test solutions and saliva samples. The results demonstrate superior performance to other PCB-based pH sensors and Na+ and K+ PCB-based sensors with comparable performance to potentiometric sensors fabricated with other techniques, paving the way towards mass-produced, low-cost, disposable, multi-parametric chemical sensing diagnostic platforms.

1 January 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
Bing LiBing Li
Bing Li
HTHaijie Tan
Haijie Tan
SASalzitsa Anastasova-Ivanova
Salzitsa Anastasova-Ivanova
MPMaura Power
Maura Power
FSFlorent Seichepine
Florent Seichepine
GYGuang-Zhong Yang
Guang-Zhong Yang
Nature is a great source of inspiration for the development of solutions for biomedical problems. We present a novel biosensor design utilizing two-photon polymerisation and graphene to fabricate an enhanced biosensing platform for the detection of motile bacteria. A cage comprising venous valve-inspired directional micro-structure is fabricated around graphene-based sensing electronics. The asymmetric 3D micro-structure promotes motile cells to swim from outside the cage towards the inner-most chamber, resulting in concentrated bacteria surrounding the central sensing region, thus enhancing the sensing signal. The concentrating effect is proved across a range of cell cultures - from 101 CFU/ml to 109 CFU/ml. Fluorescence analysis shows a 3.38-3.5 times enhanced signal. pH sensor presents a 2.14-3.08 times enhancement via the detection of cellar metabolite. Electrical measurements demonstrate an 8.8-26.7 times enhanced current. The proposed platform provides a new way of leveraging bio-inspired 3D printing and 2D materials for the development of sensing devices for biomedical applications.

28 July 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
ASAnna-Maria Spehar-Délèze
Anna-Maria Spehar-Délèze
SASalzitsa Anastasova-Ivanova
Salzitsa Anastasova-Ivanova
Pankaj VadgamaPankaj Vadgama
Pankaj Vadgama
Lactate electrochemical biosensors were fabricated using Pediococcus sp lactate oxidase (E.C. 1.1.3.2), an external polyurethane membrane laminate diffusion barrier and an internal ionomeric polymer barrier (sulphonated polyether ether sulphone polyether sulphone, SPEES PES). In a needle embodiment, a Pt wire working electrode was retained within stainless steel tubing serving as pseudoreference. The construct gave linearity to at least 25 mM lactate with 0.17 nA/mM lactate sensitivity. A low permeability inner membrane was also unexpectedly able to increase linearity. Responses were oxygen dependent at pO2 < 70 mmHg, irrespective of the inclusion of an external diffusion barrier membrane. Subcutaneous tissue was monitored in Sprague Dawley rats, and saliva and sweat during exercise in human subjects. The tissue sensors registered no response to intravenous Na lactate, indicating a blood-tissue lactate barrier. Salivary lactate allowed tracking of blood lactate during exercise, but lactate levels were substantially lower than those in blood (0–3.5 mM vs. 1.6–12.1 mM), with variable degrees of lactate partitioning from blood, evident both between subjects and at different exercise time points. Sweat lactate during exercise measured up to 23 mM but showed highly inconsistent change as exercise progressed. We conclude that neither tissue interstitial fluid nor sweat are usable as surrogates for blood lactate, and that major reappraisal of lactate sensor use is indicated for any extravascular monitoring strategy for lactate.

1 June 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
BGB. Gil
B. Gil
SASalzitsa Anastasova-Ivanova
Salzitsa Anastasova-Ivanova
GYG.-Z. Yang
G.-Z. Yang